We are leaders in the market for providing best range of Encoder Splitter 1000 KHz, 24/12/10/5 VDC @1.5A Regulated Power Supply, 24 VDC Regulated Power Supply, PMDC Drive and variable power supply

HTL To TTL Converter

Features: . Output of type Source Sink Push Pull in single module. Input in the range 3-10 VDC and 12-30 VDC (Peak to peak voltage)Minimum Driving current: 1.6 mASupply voltage:24-30 VDC@300mA . Output pulse train voltage adjustable from 4 28 VDC by presetMaximum input frequency 2000 KHzReduces high frequency noise and gives clear square wave
View Complete Details

Encoder Splitter 1000 KHz

Features: Input signals 3-10 or 10-30VDCSink / Source/ Push pull / Open collector (Transistor) outputs.Supply voltage 24-30 VDC@1AmpOutput pulse voltage 5/10/24 VDC as per customers requirement.Each output can drive150mA load.Din rail mountable
View Complete Details

Optoisolator Board

Features DIN rail mountableFourFiveSixEight optoisolators on single boardLED indication for input signalPositive supply commonnegative supply common selection by jumpers234 Outputs can be grouped to same supply by jumpers Technical Specifications Input signal voltage:20 VDC-28VDC, Typical voltage is 24VDCMax. input current:25 mA @24VDCMax. output voltage:65 VDCMin.output voltage:2.0 VDCMax. load per output point:50 mAContinuous power dissipation at (or below) 25C free-air temperature: 200mWInput to output electrical isolation: 3.55 KVMax. Voltage drop in output voltage: 0.5 V @ 5mA loadResistance, input to output: 100 GSwitch ON delay: 5SSwitch OFF delay: 5S Applicationsa) For connecting invertersServo drives to PLC output modules.b) To convert NPN sensor to PNP sensor and vice versa.c) For isolating field inputs from PLC input module.d) To connect incremental encoder (With Incompatible signal level) to control system.e) In all applications where we need very fast and require isolation between driver and driven circuits.f) For connecting one signal level (5-230 VDC)to another signal level (2-65 VDC)with isolation.g) To make field inputs noise free. Available in 4points5 points6 points8 points variants.Opto. boards with input signal other than 24VDC can be supplied on demand.High speed switching 2S possible on demand. StandardApprovals CE CertifiedPCB:IEC61373Terminals:ULCEOptoisolator:ULProfile & end plates:CE
View Complete Details

Two Stage Voltage Sensing Relay

Features:DIN rail mountableLED indication for relay statusExternal power supplySignal supply selectable by jumper.Input voltage can be ACDC of up to 2000V Applications: *Voltage safety monitoring*Overvoltage monitoring*Configuring speed dependent relay by connecting analogue tachogeneratoroutput to the module*Safety voltage monitor in Solar panel
View Complete Details

Redundant Power Supply Modules

Technical Specifications I) Suitable for 6Amps 10Amps 25Amps power suppliesii) Input max: 100VDCiii) DIN rail mountableIV) 1000VDC PIVv) Power supply ON indications ApplicationsTo use power supply redundancy in control system
View Complete Details

Encoder Splitter Multiple Outputs

Feature Input signals 3-10 or 10-30VDC10 Encoder output sets from single encoder inputSink Source Push pull Open collector (Transistor) outputs.Supply voltage 24-30 VDC@1AmpOutput pulse voltage 51024 VDC as per customers requirement.Each output can drive150mA load.Din rail mountable
View Complete Details

24/12/10/5 VDC @1.5A Regulated Power Supply

Technical Specifications Regulated power supply 24 VDC12VDC10 VDC5 VDC@ 1.5A or 3.0AInput:2 30 VAC, 5060HzOutput has short circuit and thermal overload protectionSurge protection provision for transformer primaryDIN rail mountable Applications Power supply inside controls panel for PLCReference power supplyAuxiliary power supply in control panelEncoder supply
View Complete Details

Differential To Single Ended Signal Converter 1000KHz Source

Features: DIN rail mountable Three (A, B, Z) outputs moduleLED indication for output signalsReduces high frequency noise and gives clear square wave output.Source type outputs Technical specifications: Input signal voltage:3-10 VDC OR 10-24VDCMax. input current:5 mA Max. output voltage:5-30 VDCMin.output voltage:5.0 VDCMax. load per output point:200 mAContinuous power dissipation at (or below) 25C free-air temperature: 200mWInput to output electrical isolation: 3.55 KVMax. Voltage drop in output voltage: 0.5 V @ 5mA loadResistance, input to output: 100 GMax pulse frequency: 1000 KHz Applications: a) For connecting simulated encoder signals from invertersServo drives to PLC inputs. b) To convert RS422 signal in to single ended signalc) To shift level of the square wave input to desired leveld) Conversion of sink type encoder to source type outputs
View Complete Details

24VDC 2CO PC Relay Board

Application Relay Interface Module 2 changeover DC used to interface 24DC digital outputs to contactorssolenoid valvesindications etc. Load and PLC ops are galvanically isolated COMPONENT SPECIFICATIONS Relay: 24VDC coil, 1 changeover OmronRelay socket: 1 changeover PCB soldering typeTerminals: Screw type suitable for 2.5 sq. mm wiresProfile and end plates: Phoenix make TECHNICAL SPECIFICATIONS Input data: Operating voltage: 24 VDC +- 10%Input current: Max 20mA@24 VDCACProtection across relay coil: Free wheeling diodeIndication: 3mm LEDNo of relays: 2 or 4 or 8Terminals: Screw type suitable for 2.5 sq. mm wiresConductor size: 025-2.5 sq. mmInsulation stripping length: 7 mm Output Data: Contact type: DPDT (2 changeover contacts NO-Pole-NC)Max. current: 5Amps@250 VAC or 30 VDCOutput wiring: Potential freeTerminals: Double decker Screw type suitable for 2.5 sq. mm wiresConductor size: 025-2.5 sq. mmInsulation stripping length: 7 mmModule dimensions (HXLXD): 125x36x70 (2 Relay board)125x70x70 (4 Relay board)125x130x70 (8 Relay board)
View Complete Details

24 VDC Regulated Power Supply

Technical Specifications Regulated power supply 24 VDC12VDC10 VDC5 VDC@ 1.5A or 3.0AInput:2 30 VAC, 5060HzOutput has short circuit and thermal overload protectionSurge protection provision for transformer primaryDIN rail mountable Applications Power supply inside controls panel for PLCReference power supplyAuxiliary power supply in control panelEncoder supply
View Complete Details

PMDC Drive

Technical Specifications Features: Supply voltage: 230 VAC 10% 110 VAC 10%Output: 0-180 VDC 0-90 VDCMaximum load current: 3 Amp 6 Amp RMSSpeed control: By means of a potentiometerProtection: Overload and short circuit protection using fuseRatings: 3Amps6 Amps(other current ratings on demand)Load: PMDC motorHeating coilIR or Incandescent LampHousing: Powder coated CRC boxSize: 135x90x55 (HxWxD)
View Complete Details

Variable Power Supply

Technical Specifications i) Regulated power supply 24 VDC12VDC10 VDC5 VDC@ 3.0A2.0Aii) Input: 230 VAC, 5060Hziii) Out put has short circuit and thermal overload protectionIV) Surge protection provision for transformer primary Applications 1) Power supply inside controls panel for PLC2) Reference power supply3) Auxiliary power supply in control panel5) Battery charger6) Encoder Solenoid valvesProximity sensorsPhotosensor power supply Other voltages (28.0V, 15.0V, 18.0 etc) on demand NOTE:- Due to continuous product development the product supplied to you may look different than the product image in the pdf file.If power supply is to be used as battery charger then customer should inform Q-Log controls about application.