Model |
Accuracy |
Measuring range |
Sensor type |
Capacity |
S500-TH-GSM |
±0.5°C/±5%RH |
-20~70°C 0~100%RH |
Temperature humidity,internal |
65000 |
S500-EX-GSM |
±0.5°C/±3%RH |
-40~85°C 0~100%RH |
Temperature humidity,external sensor with 3 meters |
65000 |
S520-TH-GSM |
±0.3°C/±3%RH |
-20~70°C 0~100%RH |
Temperature humidity,internal |
65000 |
S520-EX-GSM |
±0.3°C/±3%RH |
-40~85°C 0~100%RH |
Temperature humidity,external sensor with 3 meters |
65000 |
S580-TH-GSM |
±0.2°C/±2%RH |
-20~70°C 0~100%RH |
Temperature humidity,internal |
65000 |
S580-EX-GSM |
±0.2°C/±2%RH |
-40~85°C 0~100%RH |
Temperature humidity,external sensor with 3 meters |
65000 |
Model |
HE701 | HE702 | HE704 |
Inputs (Channels) |
1 |
2 |
4 |
Output Method |
Analogue output1~10V |
RU18-DU90-VK1 |
RU18-DU160-VK1 |
NPN-NO/NC |
RU18-DU160-NK1 |
RU18-DU160-NK1 |
|
PNP-NO/NC |
RU18-DU90-PK1 |
RU18-DU160-PK1 |
|
Maximum sensing distance |
900mm |
1600mm |
|
Sensing ranger(sd): |
100~900mm |
150~1600mm |
|
Beam angle: |
±7° |
±8° |
|
Frequency transducer: |
300KHZ |
230KHZ |
|
Repeat accuracy: |
0.50% |
||
Working Temperature: |
-10°C~ 60°C |
-20°C~ 70°C |
Output for Relative Humidity
Relative humidity %RH |
20 |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
95 |
Voltage Output V |
0.6 |
0.9 |
1.2 |
1.5 |
1.8 |
2.1 |
2.4 |
2.7 |
2.85 |
Function |
Range |
Resolution |
DC mA Input |
0 ~ 24 mA |
0.001 mA |
DC mA Output |
0 ~ 24 mA |
0.001 mA |
Range |
Resolution |
Accuracy ±(% of reading Counts) |
100 mV |
0.01 mV |
0.02 % 3 |
20 V |
0.001 V |
0.02 % 3 |
Input impedance: 2MΩ (nominal),< 100pF Over voltage protection: 30 V Voltage driver capability: 1 mA |
DC mA Input and Output
Range |
Resolution |
Accuracy ±(% of reading Counts) |
24 mA |
0.001mA |
0.015 % 3 |
Model:TH100 |
|||||
Rated voltage |
DC12V |
||||
Measuring range |
Temperature |
-20oC~70oC |
Humidity |
0-100%rh |
|
Measuring accuracy |
Temperature |
±0.5oC |
Humidity |
±4.5%rh |
|
Output range |
communication RS485 MODBUS protocol |
||||
Temperature |
-20oC~70oC |
Humidity |
0-100%rh |
||
Electrical isolation |
Between the communication port |
AC500V,1mA, 1min |
|||
Between communication end and the main circuit |
AC500V,1mA,1min |
||||
EMC indicators meet |
N 55022 CLASS B, EN 55024,CISPR 22 CLASS B, CISPR 24 IEC 61000-3-2,IEC61000-3-3,IEC 61000-4-2, IEC 61000-4-3,IEC61000-4-4,IEC61000-4-5, IEC 61000-4-6,IEC61000-4-8,IEC 61000-4-11 Meet the national standard:GB 9254 CLASS B, GB/T 17618 GB 17625.1, IEC 17625.2, GB/T 17626.2, GB/T 17626.3, GB/T 17626.6,GB/T 17626.8, GB/T 17626.11 |