Post Buy Requirement
PI

Pyrotron India Inc

Add Review

Our Products

  1. Products 77 Products available

Our Products

Leading Manufacturer, Supplier & Retailer of Multi- Point Process Scanner, Paramagnetic Oxygen Analyzer, Temperature and Humidity Recorders, Alarm Temperature Humidity Data Logger and Paper Less Recorder.

Multi- Point Process Scanner

  • Model Number CTM-1X ·
  • Theory Temperature Controller
  • Accuracy ±0.5%F.S, +-0.5%F.S
  • Temperature range -1999-9999℃
  • Power supply 85-265VAC, 50/60Hz
  • Channel 1-16channel
  • Input RTD, TC, 4-20ma, 0-10v etc.
  • Display unit 4 digit 1.0inch LED
  • Alarm two relay contact(250VAC, 3A)
  • Usage Industrial
View Complete Details

Paramagnetic Oxygen Analyzer

3.48 /Number Get Latest Price
  • Min. Order (MOQ) 1 Number
  • Application Laboratory Use
  • Automation Grade Automatic
  • Model PM900
  • Voltage 230 V
  • Frequency 50/60 Hz
View Complete Details

Temperature And Humidity Recorders

  • Mounting Length Size 131.5mm
  • Mounting Width Size 131.5mm
  • Product Length Size 144mm
  • Product Width Size 144mm
  • Product Depth Size 83mm
  • Power Supply 12V AC / DC ~ 24V AC / DC,
  • Power supply 90 ~ 264VAC, 50/60HZ is available by connecting external power adaptor
  • Temperature Measuring Range -50.0 ~ 120.0 Deg c
  • Temperature Accuracy ± 0.5 for the range -30 ~ 20 Deg C
  • Temperature Sensor Type NTC (sensor wire length five meters)
  • Humidity Measuring Range 0Deg C -95%RH
  • Humidity Accuracy /-5%RH
  • Temperature Sensor Type Honeywell
  • Display Resolution 0.1
  • Recording Cycle 1 minute to 24 hours continuously set
  • Recording Capacity each 130, 000 points (MAX)
  • Ambient Environment Temperature -35 ~ 70 ;Humidity 0% ~ 95%
View Complete Details

Alarm Temperature And Humidity Data Logge

  • High accuracy (0.2~0.5°C/2~5%RH)
  • large capacity (65000)
  • Features Elegant appearance, easy to operate and reliable. Desktop and wall-mounted

Model

Accuracy

Measuring range

Sensor type

Capacity

S500-TH-GSM

±0.5°C/±5%RH

-20~70°C 0~100%RH

Temperature humidity,internal

65000

S500-EX-GSM

±0.5°C/±3%RH

-40~85°C 0~100%RH

Temperature humidity,external sensor with 3 meters

65000

S520-TH-GSM

±0.3°C/±3%RH

-20~70°C 0~100%RH

Temperature humidity,internal

65000

S520-EX-GSM

±0.3°C/±3%RH

-40~85°C 0~100%RH

Temperature humidity,external sensor with 3 meters

65000

S580-TH-GSM

±0.2°C/±2%RH

-20~70°C 0~100%RH

Temperature humidity,internal

65000

S580-EX-GSM

±0.2°C/±2%RH

-40~85°C 0~100%RH

Temperature humidity,external sensor with 3 meters

65000

View Complete Details

Paper Less Recorder

  • Frequency 1Hz
  • Communication RS485 mode Complying with open MODBUS RTU slave protocol,
  • baud rate can be set 1200/4800/9600/19200/38400/57600 bps.
  • Screen Display Resolution 192×64 Scan
  • Power Supply Rated AC supply voltage 0.2A @ 90-260VAC, 45-55Hz.
  • Size Outline size 160mm(Width)×80mm(Height)×48mm(Depth) Hole size
  • Net weight ≤1.0kg.
  • Storage condition Temperature -20-60oC. Avoid direct exposure
  • violent sunlight Humidity <85%RH (no coagulation).
  • Operating condition Temperature 0-55oC
  • Humidity 10-85%RH (no coagulation).
  • Notes Do not operate in an erosive atmosphere. Do not bring liquid or conductive substance into the instrument. Keep airiness near the intake in a good condition.
View Complete Details

Circuler Chart Recorder

  • Features Enhanced Durability, Optimum Performance, Compact structure
View Complete Details

Temperature Data Logger

  • Accuracy ±1.0°C ±0.3%FS
  • Weight 150g(without battery) / 200g(with battery)
  • Dimensions 187mm * 73mm * 53mm
  • Memory 43, 000 readings
  • Measurement Range -30 to 70°C (-22 to 158°F)
  • Storage Temperature -35 to 80°C (-31 to 176°F)
  • Resolution 0.1°C
  • Battery 9V
  • Typical battery life 1 week
  • Logging rate 1s ~ 24h
  • LCD display area 42mm * 20mm
  • Accessories ToAnalyzer 1 CD, USB cable, User Manual, Battery.
  • Features LCD display with backlit, Max Hold and Data Hold, Mini USB interface, 36, 000 log readings

Model

HE701 HE702 HE704

Inputs (Channels)

1

2

4
View Complete Details

Temp. Data Logger RC4

  • Accuracy 1°C;
  • Product size 84mm (length) X 44mm (width) X 20 mm (height)
  • emperature unit °C or °F optional
  • Temperature measuring range -30°C~ 60°C;for optional external sensor, -40°C~ 85°C;
  • Ambient environmental temperature -30°C~ 60°C;
  • Resolution 0.1°C;
  • Record capacity 16000points(MAX);
  • Record interval 10s~24hour adjustable;
  • Sensor Internal NTC thermal resistor;
  • Power supply inner CR2450 battery or power supply via USB interface;
  • Battery life in normal temperature, if the record interval sets as 15 minutes, it could be used above one year.
View Complete Details

Ultrasonic Level Sensors USL 5000/8000 A

  • Applications Water, sewage, slurry, large storage tanks, ponds, pits, juices, light aggressive liquids, beverages, acids,
  • Features Fully Temperature compensated., LCD display., Intellectual signal treatment., 4-20mA, 2 wire current output, Higher resolution and accuracy
View Complete Details

USL 5000/8000 Ultrasonic Level Sensor

  • Frequency 20KHz - 350 KHz
  • Output 4-20mA, Rs485, 0-5 V Dc
  • Material ABS Shell, PP for Transducer
  • Sansing Range 5M, 8M
  • Blind Area .3M, .5M
  • Emission Angle 120
  • Power 12-24 V Dc
  • Max load impidance 300 Ohm
  • Resolution 1 mm
  • Working Temp. -10 - 700 C
  • Humidity 0-95%
  • Extension Cable 1.5 Mt
  • Mounting M48 Hole Screw Type
  • Size M48x110 mm
  • Pay Mode Terms L/C (Letter of Credit)
View Complete Details

RU 18 Ultrasonic Level Sensors

  • Temperature compensation: YES
  • Operating voltage: DC15~30V
  • Thermal drift: <5%
  • Ripple: 5%
  • Leakage current: <10μA@VDC=30V
  • Output current: 100mA
  • Minimum load resistance: 1KΩ(analogue voltage output/10V)
  • Adjustment set pint: Teach-in button
  • Time delay before availability: 300mA
  • Output protection: Polarity reversal;over voltage pules;short circuit
  • Protection degree: IP65
  • IP66 Housing material:
  • PBT Active heat material:
  • Epoxy resin Tightening torque:
  • Tightening torque 1Nm Weight:
  • 35g Storage temperature:

Output Method

Analogue output1~10V

RU18-DU90-VK1

RU18-DU160-VK1

NPN-NO/NC

RU18-DU160-NK1

RU18-DU160-NK1

PNP-NO/NC

RU18-DU90-PK1

RU18-DU160-PK1

Maximum sensing distance

900mm

1600mm

Sensing ranger(sd):

100~900mm

150~1600mm

Beam angle:

±7°

±8°

Frequency transducer:

300KHZ

230KHZ

Repeat accuracy:

0.50%

Working Temperature:

-10°C~ 60°C

-20°C~ 70°C

View Complete Details

UB 400 Ultrasonic Level Sensors

  • Sensing range 30 . 400 mm
  • Adjustment range 50 . 400 mm
  • Unusable area 0 . 30 mm
  • Standard target plate 100 mm x 100 mm
  • Transducer frequency approx. 310 kHz
  • Response delay approx. 50 ms
  • LED yellow indication of the switching state flashing: program function object detected
  • LED red solid red: Error red, flashing: program function, object not detected
  • Operating voltage 10 . 30 V DC , ripple 10 %SS
  • No-load supply current ≤ 30 mA
  • Output type 1 switch output E4, NPN, NO/NC, programmable
  • Rated operational current 100 mA , short-circuit/overload protected
  • Voltage drop ≤ 3 V
  • Repeat accuracy ≤ 1 %
  • Switching frequency ≤ 8 Hz
  • Range hysteresis 1 % of the set operating distance
  • Temperature influence ± 1.5 % of full-scale value
View Complete Details

SYH- 1 Humidity Transmitters

  • Theory Resistance Sensor
  • Output Switching Transducer
  • Brand Name syhitechsamyoung
  • Usage Humidity Sensor
  • Model syh-1
View Complete Details

Temperature Data Logger RC 4

  • Product size 84mm (length) X 44mm (width) X 20 mm (height)
  • Temperature measuring range -30°C~ 60°C;for optional external sensor, -40°C~ 85°C;
  • Temperature accuracy -30°C~ 60°C, ±1°C;others, ±1.5°C;
  • Temperature unit °C or °F optional, set through RC-4H data management software.
  • Humidity measuring range 0~99%RH
  • Humidity accuracy ±3%RH(25°C, 20~90%RH), others, ±5%RH;
  • Resolution Temperature 0.1°C;Humidity 0.1%RH;
  • Record capacity RC-4HA 8000points(MAX); RC-4HC 16000points(MAX);
  • Record interval 10s~24hour adjustable;
  • Power supply inner CR2450 battery or power supply via USB interface;
  • Battery life in normal temperature, if the record interval sets as 15 minutes, it could be used above one year.
View Complete Details

Humidity Transmitters 1001

  • Accuracy humidity -5%RH
  • Features Temperature compensated, Good price, Fast delivery, 0.6-2.7V DC output
  • Model MM1001
  • Power supply 4-5.5V DC
  • Output signal 0.6- 2.7V DC
  • Sensing element Polymer resistor
  • Detecting range 20-95%RH;
  • Ambient temp. range 0~60Celsius
  • Resolution or sensitivity %RH;
  • Repeatability -1%RH;
  • Humidity hysteresis -1%RH
  • Long-term Stability -1%RH/year
  • Response time 10s(average)
  • Interchangeability fully interchangeable
  • Dimensions size 22*28*5mm

Output for Relative Humidity

Relative humidity %RH

20

30

40

50

60

70

80

90

95

Voltage Output V

0.6

0.9

1.2

1.5

1.8

2.1

2.4

2.7

2.85

                                                               
View Complete Details

Humidity And Temperature Indicator RHC 401

  • Feature Hassle-free operation, Sturdiness, Excellent performance
  • Model No. RHC401
View Complete Details

RH-Temp Humidity Transmitters

  • Features quality norms and standards using high grade raw material to ensure quality.
View Complete Details

CHT- Rs 485 Digital Transmitter

  • Model No. CHT- Rs 485
  • Features Easy to operate, Reliable operation, Feasible prices
View Complete Details

Pressure Transmitter

  • Feature High accuracy, span and zero points: outside continuous and regular table, Good stability
  • Analog accuracy 075% 0.1%f.s
  • Overall performance 0.25f.s
  • Stability 0.25%
  • Ratio of spans 1001
  • Measuring speed 0.2s
View Complete Details

ATX Series Temp. Transmitter

  • Supply Voltage DC 18~24V
  • Input RTD (pt100Ω)
  • Thermocouple signal K . J . E
  • T Output signal 4 ~ 20mA
  • Measured temperature - 270 °C~ 1820 °C
  • Isolation voltage 1500VAC between sensor and loop
  • Operating humidity 30 ~ 90%
View Complete Details

Signal Isolator

  • Design Based on F/V and V/F linear circuit.
  • Input types RTD (Pt-100) / 2 or 3 wire or Thermocouple (J/K/ Types – type to be specified) or mV, mA input or Load cell, pressure sensor, pH/ORP sensor etc. generating DC current or voltage. AC input - Current (through external CT) (0-1)A or (0-5)A or Voltage (0-11
  • Range User may specify the required temperature range (for RTD or T/C input). For other inputs the required calibration range can be specified.
  • Output (4-20) mA, (0-20) mA, (0-1) VDC, (0-5) VDC, (0-10) VDC, Frequency (0-1)KHz, (0-5)KHz, (0-10)KHz etc. proportional to the specified input range. For current output, RL (max.) = 500 Ohms. For voltage output, RL (min) = 10K Ohms.
  • No. of Outputs Maximum 4 parallel independent outputs can be provided for single input.
  • Accuracy For Thermocouple and RTD Input, the calibration of output is done for the best straight line fit to give accuracy of /- 0.5% of the range. For other input the linearity depends on the input signal, where output accuracy is absolute to the input.
  • Calibration On site calibration facility through ZERO and SPAN presets accessible to the user.
  • Isolation Input and Output are optically isolated for DC and frequency inputs and galvanically isolated for the AC inputs.
  • Isolation Voltage Greater than 2.5KV.
  • Mounting DIN rail mounting ABS enclosure.
  • Supply 90 -260 VAC, 50/60Hz or 24VDC @ 200mA
  • Size 65(W) x 80(H) x 125(D) mm.
View Complete Details

Diffrential Pressure Transmitter

  • Feature High accuracy, Continual setting of span and zero point can be realized from outside
  • Digital accuracy 0.05%
  • Analogue accuracy .075% 0.1%F.S
  • Overall performance 0.25F.S
  • Stability 0.25% 60 months
  • Measuring speed 0.2S
View Complete Details

I/P Transmitters

  • Features Low Cost, Built-in Volume Booster, Small Size, Field Reversible, Low Air consumption, Mounts at Any Angle
View Complete Details

Air Pressure Regulator

  • Accurate Pressure Regulation Controls output pressure to within 0.1% accuracy. Regulated pressure variation as small as 0.01 psig is self corrected
  • Stable Output Substantial changes in flow have virtually no effect on regulated pressure from dead end to 12 SCFM.
  • Dependable Startup Returns the regulated pressure to its original output setting even after long “down time”
  • High Relief Capacity An optional high flow relief valve provides quick response, when regulated pressure is reset to a lower value or when there is a large amount of system back pressure to be relieved
  • Temperature Stability A stainless steel measuring capsule which activates the servo control mechanism minimizes effects on regulated pressure by wide variations in operating temperature.
  • Locking Capability Locking nut prevents inadvertent pressure adjustment.
View Complete Details

Pressure Transmitters Model No PT210BX

  • Feature Adopting explosion proof shell, All stainless steel sealed construction, Corrosion-resistance, Higher accuracy, Well long term stability, LED display, Zero and span adjustable.
  • output signal 2mV/V3.33mV/V100mV/V 020mA 420mA05V 15V10V
  • Ranges 100KPa10KPa200MPa
  • combined accuracy  0.25%FS0.5%FS1%FS
  • Overload pressure 150% FS
  • Operating temperature -40125
View Complete Details

Pressure Transmitter (PT)

  • Feature All stainless steel sealed construction, corrosion-resistance, various configuration, Wide temperature compensation
  • output signal 1mV/V 1.5mV/V 2mV/V 3.33mV/V 020mA; 420mA 05V15V 010V
  • Ranges -100KPa10KPa200MPa
  • Combined accuracy : 0.25%FS0.5%FS1%FS
  • Overload pressure 150% FS
  • Excitation 10612VDC 24V1236VDC
  • Operating temperature 40125
  • Electric connection 5 pinM126pin or hirschmann
  • Mounting M12×1.5M20×1.5G1/4
View Complete Details

Carbon Monoxide Alarm

  • Power Supply 110V-230VAC 50/60Hz.
  • Features High reliability, Advanced semiconductor sensor, Electro-chemical CO sensor, Professional low profile design
  • Model HD1100D
  • Detecting principle Advanced semiconductor sensor & Electro-chemical CO sensor
  • Calibration gas Methane/LPG/LNG and Carbon monoxide
  • Alarm level 7%LEL and 50ppm
  • Accuracy /-3%LEL
  • Audible alarm level 85dB at 1m
  • Power consumption 2.5W
  • Temperature -10℃ 55℃
  • Humidity ≤95%RH (no condensation)
  • Size 118mm (L)×78mm(W) ×38mm(H)/ (4.6’’)L*3.1W’’*1.5’’H.
  • Net Weight 330g
  • Wiring plug-in
  • Lifetime/Warranty 5years/ 2 years.
View Complete Details

Universal Process Indicator

  • Application Suitable for two wire transmitter, Process Sensor, Four wire weight Sensor, Other sensor application
View Complete Details

Process Indicator

  • Application Used for measuring any range of voltage/current signals, Can select data holding or peak value holding functio
  • Power Supply 90V-260V AC/DC
  • Consumption <5 W
  • Relay capacity 250VAC/3A or 30VDC/5A
View Complete Details

Process Indicator SI 08A

  • Input Signals accept signal from
  • Thermocouple (J, K, E, T, R, S)
  • RTD pt - 100 /Cu-50,
  • Analogue 0 ~ 10 VDC / 4~20 mADC
  • Alarm high & low alarm
  • Output Relay C/O contact
  • Re-transmission 4~20mAdc
  • Auxiliary Power 24 V Dc
  • power 180 ~ 264 vac. 50hz. /24 V DC
  • Bazel size 48 x 96 mm
View Complete Details

Sensor Indicator PI Series

  • Accuracy ±0.3 “FS±dight
  • Input A (AC/DC), mA, mV, V, Rt, Pt, for optional by software.
  • Up to 3 relay alarm. Capacity AC 250V/3A or 30V/3A
  • With isolated analogue outpuT 0-10mA or 4-20mA
  • Auxiliary power 24V/12V, max.DC30mA
View Complete Details

Digital Temperature Humidity Hydro Thermometer Ind

  • Material Plastic
  • Color White
  • Accuracy ±1°C(or±2°F), ±5%RH
  • Dimensions 110*100*20 mm LCD VA, 80*60MM
  • N.W 137G/PCS
  • Power Supply 1.5V
  • Battery Type AAA Battery
  • range -50°C~70°C(-58°F~158°F)
  • Measuring humidity range 10%RH~99%RH
  • specification Digital Home Temperature Humidity, Hydro-Thermometer Indicator, Temperature Humidity Thermometer
View Complete Details

PID Controller

  • Payment Mode L/C (Letter of Credit)
  • Input Universal (T/C, mV, 4-20mA)
  • Display Dual line Bright LED
  • Output Relay, SSR, 4-20mA, Thyristor zero trigger
  • Alarm 1 Alarm Relay Output
  • Tuning auto tuning
  • Accuracy 0.5% /- FS Or 1 Digit
  • Bazel Size 48x48 mm, 72x72 mm, 48x96 mm, 96x96 mm
View Complete Details

Micro Process PID Controller

  • Feature Overshoot supression, Super large and bright LED Display, Dual output for heating cooling.Two individual PID, RS-485, 4-20mA Re-Transmission optional
  • Power supply 85~265VAC 50/60HZ
  • Input Universal input(TC, RTD, Analog)
  • Display Dual line four digits LED display
  • Output Relay/SSR/4-20mA/Triac
  • Control PID Auto-tuning function
  • Accuracy 0.2%F.S
  • Available size 48mm*48mm, 48mm*96mm(Horizontal), 72mm*72mm, 96mm*96mm, 96mm*48mm(Vertical)
  • Mounting Panel Mount
View Complete Details

Micro Process Temperaertue Sensor

  • Features Moreover, client can get the provided products from us at very economical prices.
View Complete Details

Thermocouple MI

  • Outside diameter 0.5-8.0
  • Temperature range -200-1300oC
  • Sheath diameter 0.5-8.0, 12.7
View Complete Details

High Temperature Thermocouple Temp 2300 Deg C

  • Feature Long life, High durability, Less maintenance
  • temperature measurement High Temp Up To 2300oC.
View Complete Details

Conductivity Level Switch

  • Features Sturdy Construction, Excellent Finish, High Durability
View Complete Details

Miniature Level Sensor

  • Features Robust construction, Reliable performance, Enhanced service life
View Complete Details

Side Mounted Level Switch

  • Features Optimum Performance, Enhanced service life, Rigid Construction
View Complete Details

Electrical PP Float Type Level Switch

  • Application Drinking fountains, water heaters, solar energy, air conditioners, humidifiers
View Complete Details

Mini Water Level Float Switch

  • Working Pressure ≤1.5MPa
  • Applications Drinking fountains, water heaters, solar energy, air conditioners
  • Product Name Mini Float Level Switch (LS-HS02)
  • Contact Capacity AC220V/1A; DC24V/0.5A
  • Float Gravity 0.7
  • Output Signal SPST NO/NC
  • Working Temperature -20~160°C
  • Protection Grade IP68
  • Float Material SUS304/SUS316L
  • Housing Material SUS304/SUS316L
  • Wire Length 500±10mm
  • Installation Method horizontal installation
  • Explosion-proof No
  • Connection 1/2″PF/PT; customized
View Complete Details

Techometer

  • Type Photo Electricity
  • Display Led
  • Rotate Speed 2.5 To19, 999 Round/Min
  • Line Speed 0.05 To 999 M/Min (dt-2235b )
  • Accuracy ± (0.05%n 1d)
  • Resolution 1r/Min(2.5 To 999, 9 Rpm)
  • Memory Value Max/Min/Last Vslue
  • Power Supply 4×1.5 Aa(um-3)battery
  • Certificate Ce Approval
View Complete Details

Hydraulic Dead Weight Tester

  • Standard Accuracy 0.025% of reading
  • Range 1 to 700 bar / 10 to 10, 000 psi
  • Traceability NPL, NIST
  • Weights Stainless steel, non-magnetic
  • Priming Direct via ram screw
  • Standard corrections - Gravity 9.80665 m/s2*
  • Standard corrections - Temperature 20°C*
  • Standard corrections - Air density 1.2 kg/m3
  • Weight Tester 9.5 kg.
  • Weights 30 kg
  • Dimensions L360 x W290 x H190 mm approx.
  • Operating Fluids - Oil Models Mineral oils to ‘SI' specifications
  • Operating Fluids - Water Models Distilled water
View Complete Details

Volt And Ma Signal Source Process Calibrator

  • DC Voltage Input 100mV±(0.02% 2), 10V±(0.02% 2)
  • DC Voltage Output 100mV±(0.02% 2), 10V±(0.02% 2)
  • DC Current Input 24mA±(0.015% 2)
  • DC Current Output 24mA±(0.015% 2)
  • Loop Power Output 24V±10% 2
  • Input Impedance 2Mnominal, < 100pF
  • Over Voltage protection 30 V
  • Voltage Driver Capability 1 mA
  • Overload Protection 125 mA, 250Vfast acting fuse
  • Current Percent Display 0%=4mA, 100%=20mA.

Function

Range

Resolution

DC mA Input

0 ~ 24 mA

0.001 mA

DC mA Output

0 ~ 24 mA

0.001 mA

 

Range

Resolution

Accuracy ±(% of reading Counts)

100 mV

0.01 mV

0.02 % 3

20 V

0.001 V

0.02 % 3

Input impedance: 2MΩ (nominal),< 100pF

Over voltage protection: 30 V

Voltage driver capability: 1 mA

DC mA Input and Output

Range

Resolution

Accuracy ±(% of reading Counts)

24 mA

0.001mA

0.015 % 3

View Complete Details

HART 475 Field Communicator

  • RAM 32 MB
  • Weight Approximately 1.65 lb. (0.75kg) with battery
  • Display 1/4 VGA (240 by 320 pixels) color, 3.5 in. (8.9 cm) transflective display with touch screen; anti-glare coated
  • Keypad 25 keys including 4 action keys, 12 alphanumeric keys, tab key, function key, backlight key, power key, and 4 cursor-control (arrow) keys; membrane design with tactile feedback
  • Battery Charger Input voltage 100-240 VAC, 50-60 Hz Cables included with U.S., Europe, and U.K. plugs
  • HART and Field bus Three 4mm banana plugs (one common to HART and FOUNDATION fieldbus)
  • Microprocessor 80 MHz Hitachi® SH3
  • Memory Internal Flash 32 MB
  • System Card IGB
View Complete Details

HART 375 Communicator

  • LCD Displany 8 lines, 21 characters per line
  • Operation Temperature rent: 0~50°C
  • Dimensions 228mm*98mm*60mm
  • Main Functions To perform test, diagnosis and inspection of HART instrument during production
  • Item Code 375
View Complete Details

Carbon Monoxide Alarms

2,250 /Piece Get Latest Price
  • Features Optimum Performance, High Durability, Rigid Construction
  • Weight 330g
  • Model Number HD1100D
  • Frequency 50/60 Hz
  • Voltage 110V-230V AC
  • Power consumption 2.5W
  • Dimensions 118mm (L)x78mm(W) x38mm(H)
View Complete Details

Water Level Meter

74,000 /Piece Get Latest Price
  • Type Digital
  • Material SS
  • Voltage 280V
  • Country of Origin Made in India
  • Usage/Application Indistrial
  • Phase Three
  • I Deal In New Only
View Complete Details

Humidity And Temperature Transmitter

  • Simplicity easy to install and use;
  • Intuitiveness LCD display, intuitive information, the keyboard is easy to operate;
  • Scalability RS485 interface for remote network management;
  • Stability it is supposed to be in continuous operation for 24hours throughout the year. No special maintenance.

Model:TH100

Rated voltage

DC12V

     

Measuring range

Temperature

-20oC~70oC

Humidity

0-100%rh

Measuring accuracy

Temperature

±0.5oC

Humidity

±4.5%rh

Output range

communication RS485 MODBUS protocol

Temperature

-20oC~70oC

Humidity

0-100%rh

Electrical isolation

Between the communication port

AC500V,1mA, 1min

Between communication end and the main circuit

AC500V,1mA,1min

EMC indicators meet 
the European standard

N 55022 CLASS B, EN 55024,CISPR 22 CLASS B,

CISPR 24

IEC 61000-3-2,IEC61000-3-3,IEC 61000-4-2,

IEC 61000-4-3,IEC61000-4-4,IEC61000-4-5,

IEC 61000-4-6,IEC61000-4-8,IEC 61000-4-11

Meet the national standard:GB 9254 CLASS B, GB/T 17618

GB 17625.1, IEC 17625.2, GB/T 17626.2, GB/T 17626.3, 
GB/T 17626.4, GB/T 17626.5,

GB/T 17626.6,GB/T 17626.8, GB/T 17626.11



View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us