An APFC panel consists of multiple capacitors of different ratings whose switching can be controlled as per requirement. An APFC panel is effective as a single point installation which can be used to control power factor for large number of loads instead of installing capacitors more...
MCC panels- These are effective used with motors to give proper protection from overload and short circuit. These are high on performance. These panels require low maintenance and can withstand extreme temperature variations.more...
Fast Acting Thyristor Switched Automatic Harmonic Filter Panel (RTPFC Panel) is real time passive tuned filter systems using Clariant make Thyristor switched modules. Capacitor Switching at precise Zero current crossover threshold, means : "NO" inrush current at switching "No Insmore...
HT automatic Harmonic Power Factor Correction Panels (HT AHPFC indoor systems) using FRAKO / CPSL make capacitors & reactors. Clariant is pioneer in proving complete (tuned + detuned) HT AHPFC scheme with advance technology and latest state of art in technical collaboration with more...
Contactor switched Automatic Harmonic Filter Panel ( AHPFC Panel ) is passive tuned filter systems using Frako, Germany make contactors & make thyristor switched module. Automatically controlled power factor regulation, low installation cost. Harmonic filters are in detuned mode more...
The Smallest Ecosine Active Version is Ideal for the reliable compensation up to the 50th harmonic, as well as reactive power, in a targeted manner.Thanks to its compact dimensions and low weight, this filter can be easily installed in any environment.For protectionclass requiremmore...
Specifications: : Specifications: 50/60Hz , Rating : 500 to 5000Kvar ,Voltage : 3.3/3.6/6.6/11/22/33 KV and Application : Pf improvement/Harmonic
APFC Panel is an integration of CRCA powder coated MS Sheet enclosure, fully wired with self healing HT capacitor, Vacuum contactor, fan, APFCR, all switchgears, with IP protection, busbar ALCU, with IEC STD.more...
Specifications: : Specifications: 50/60Hz , Rating : 200A + 1000Kvar , Voltage : 400/440/480..690 , Mode of Switching : Static and Application : Pf improvement Harmonic Reduction
Active : IGBT-Based Power Converter that reduces harmonic distortion Hybrid : Combination of passive and active filters Reduces THD upto 5% to 8% Dynamic Correction of THD is Possible Improves Distortion PF Load Balancing and Displacement PF improvement Possible Modular - Can be more...