Post Buy Requirement
PE

Proton Electronics Pune, Maharashtra

Pune, Maharashtra, India
Add Review

Our Products

  1. Measuring Instruments & Equipment 4 Products available
  2. Relays

    2 Products available
  3. Window

    1 Products available
  4. Air Compressor

    1 Products available
  5. Vending Machine

    1 Products available
  6. Printing Machines & Equipment

    1 Products available
  7. Instrumentation & Control Equipment

    1 Products available
  8. Timer Switch

    1 Products available
  9. Engine Components

    1 Products available
  10. Starters

    1 Products available
  11. Others Products 5 Products available

Other Products / Services #3831559

Leading Manufacturer, Supplier & Retailer of .

Air Conditioner Controller

  • Spacemaker MODEL Acc-05-09, Acc-10-02
This cutting edge airconditioning system Controller is specially designed for Unmanned Telecom Shelters. Spacemaker comes to you with unique safety features, lower power consumption and lower operating costs.Micro controller Based technology to protect your Air Conditioning unit against Unhealthy Conditions. Idea is to utilise equal run time for all Compressors with protection. Power saving is also one of the criteria to use this controller.Application areas are Server rooms, Malls, Laboratories, Pharmaceutical companies, mobile shelters , etc.
View Complete Details

Frequency Relays

  • Supply Voltage 3 Phase 415 VAC, 50 Hz
  • ON Delay 1 to 60 sec.
  • Operating Temperature range 5 degree C to 60 degree C.
Protection of 3 Phase devices against Over voltage, Under voltage, (UB) Single Phasing, (SPP) Over Frequency, Under Frequency, Reverse Phasing & Unbalance supply are one of the major issues in electrical systems. For safe running of 3-phase devices, special protections that keep a continuous watch on supply conditions are very essential. The major cause of maximum load burn-out is overloading, which occurs due to Unbalance Supply, Single Phasing or Reverse phasing conditions. VFR3P detects such conditions & protects the load from the burn out. 'Proton's VFR 3P' offers above protections along with 3 digit display showing R-Y, Y-B, B-R, voltages in scanning mode with precise accuracy.LowHigh voltage tripping to ensures trouble free running of 3-phase Loads, and also protection is provided against Over Under Frequency
View Complete Details

Annunciator Windows

  • Size 300(W) x 210(H) x 120(D) mm.
  • Supply Voltage 90-270 VAC/DC or 20-60 VDC
  • No. of window 12 Window (4R - 3C).
  • Power Consumption 0.8 VA per window
Based on latest single chip microcontroller technology, Compact design for reliable and accurate operation, Fast response time, Field selectable operational sequences, Incorporates a group of super bright LED's instead of twin Filament lamps for ultimate life at very less power consumption, Actuated thro' potential free fault input contacts, Fault input contacts NONC site selectable by means of DIP switches, Opto-isolated all fault inputs, immune to noise disturbances, Provision for external audible (Bell or Hooter) thro' potential free relay output contact, All models are with built-in Test, Silence(optional), Accept & Reset push buttons, provision on back side terminal strip, Specially designed power supply for high noise immunity, Wide input variations & having built-in transient protection, The extensive protection so provided safeguards all I.C.'s & components from failure, thereby offering complete reliability, All cards interconnected with plug-in polarized connectors for easy servicingType tested for noise, impulse and functional test as per various standards
View Complete Details

Air Conditioner Compressor

  • Size 55mm x 65mm x 125mm
  • System Supply 230 VAC +/- 15%
  • Output AC 25 A at 230 VAC
  • Power On Delay time 5 sec
Compressor guard 1 AC controls 1 AC while 2 AC model controls 2 AC'sProtections against overload (Electronic Current sensing type), Under Voltage and Over Voltage.Continuously adjustable overload setting to suit different capacities of compressor.Manual Reset by means of Power ON OFF switch for overload tripping and auto.Reset for under over voltage tripping.In single AC model power on delay timer of fixed time delay as per customers specifications to provide sufficient time to equalise the pressure. Timer comes into operation every time the compressor goes OFF, either due to power failure or due to safety protection operated in this unit. Adjustable time delay by means of DTP switches in four steps of seconds minutes ( optional features on extra cost.)In 2 AC model, power -on delay timer of 2min. 15 sec. to provide sufficient time to equalise the pressure.
View Complete Details

Electronic Buzzer

  • Supply Voltage 90-270 VAC/DC or 12V DC, 20-60 VDC.
  • Over all Size 96(W) x 96(H) 80 (D) mm
Prompt detection and rectification of any system failure or maloperation is of vital importance for any power or process plant. PROTON Alarm Annunciators continuously monitor the various process parameters and equipment status in power-stations, process plants and these parameters are displayed at centralised control room or on control panel. PROTON Annunciators stand for instant alarming of any abnormal condition occurs during process and protect the valuable equipments. PROTON Annunciators ensure the higher order of reliability and thus provide a comprehensive service to the industry for monitoring, alarm and control of process plant parameters. These highly advanced and compact systems use the latest single chip micro-computer technology for it's design and offer multipoint annunciation with operating sequences as per prevailing standards and with many optional features as indicated aside.
View Complete Details

Digital Timer Switch

  • Input Supply 230VAC +/- 15 %, 50Hz
  • Dimension 85(W) X 190 (L)
  • O/P Contacts Rating 30 amps At 230 VAC
An air conditioner timer allows you to set the time it runs for and, more often, how many hours it should wait to start cooling again. The conditioner's timer automatically turns on the machine when you program it and turns it off when the period you have set expires. Time Sharing Between 2 AC's which Increases the Life of an AC.The heart of an Air conditioner is its compressor hence some protection means must be provided to the compressor to protect it from abnormal conditions such as Over voltage, Under voltage , Over Loading, etc. The efficiency of an Air conditioner depends on its Compressor. The compressor geys damaged due to unhealthy conditions such as Over voltage, Under voltage etc. & frequent startstop without prior time delay for pressure equalization.
View Complete Details

Engine Safety Unit

  • Supply Voltage 230 VAC +- 15 %.
  • Auxiliary Supply 12VDC.
Engine Safety units are designed for the protection of DG sets in case of a fault or in case any of the safety installed on the DG sets trip. Safety potential free contacts of LLOP.HWT, LFL etc can be installed and used to stop the DG set. LLOP is sensed only when DG voltage becomes healthy.
View Complete Details

Single Phase Protection Relay

  • Supply Voltage 3 Phase 415 VAC, 50 Hz
  • ON Delay 1 to 60 sec.
  • Relative HumidityC 10% to 95%
Protection of 3 Phase devices against Over voltage, Under voltage, Single Phasing, Reverse Phasing & unbalance supply are one of the major issue in electrical systems. For safe running of 3-phase devices, special protections that keep a continuous watch on supply conditions are very essential. The major cause of maximum load burn-out is overloading which occurs due to unbalance supply, Single Phasing & Reverse Phasing conditions. VMR3P detects such Conditions & protect the load from burn out. PROTON's VMR 3P' offer above protections along with 3 digit display showing R-Y, Y-B, BR voltages in scanning mode with precise accuracy. LOWHIGH voltage tripping to ensure trouble free running of 3-phase Loads.
View Complete Details

Mobile Starter

  • Input Supply 50 HZ AC
  • Enclosure 100(W) X 190 (H) X 95(D) mm.
This wireless GSM remote controller helps the farmer to control agricultural pump sets easily. It also helps the farmer to irrigate the crops in proper schedule. Farmer can set the total running time of pumpset to be run. This saves water, time and electricity. GSM motor starter is a must device for farmers in today's world. This mobile starter protects the motor from low voltage, over voltage, dry Run, over Load.Some features are: Local language support, single phase preventer, auto starter , etc. Primary cause of motor failure is excessive heating, which is sustained over long time periods will result in motor burn out. Overheating also reduces the life of motor. If a motor is continuously overheated by just 10 degrees, its life can get reduced by almost 50%. Overheating normally occurs due to Over Current,
View Complete Details

Tap Position Indicator

  • Aux. Supply 90 – 270 VAC
  • No. of Taps 1-17 - 21 Tap (3 wire)
  • Display 2 Digit 0.5” LED.
We are one of the trustworthy names in offering range of Tap Position Indicator to our respected clients. Our offered products Tap Position Indicator is widely demanded for its portability, efficient performance and less power consumption.Two 0.5 display for display the output current, Three Keys to operate or to set the tap position and enter the password, Password protected unit, Selectable from 1-17 - 21 tap position,
View Complete Details

Gsm Controller

  • Input voltage 230VAC, 50Hz
  • Resolution 0.1 A
  • Dimensions 165 (W) X 60 (L) X 115 (H).
The Industrial RO control panel provides for very convenient mounting and easy field cable terminations. Removable terminals blocks are provided for easy terminations. Different sizes of terminals are selected for process and power connections to avoid wrong connections. The industrial RO control panel is based on state of the art technology processor. It has 6 digital inputs and four outputs. It also has Conductivity and Flow (pulse type) Sensor inputs. It can be set for Manual pre-treatment operation or Automatic pre-treatment operation. On powering the controller it checks for Raw Water Tank (RWT) level and the Treated Water Tank (TWT) level. On receiving signals that the RWT is not empty and TWT is not full, it starts up the Raw water Pump (RWP). A Low Pressure Switch (LPS) check the pressure developed at the suction of HPP. On receiving the signal that pressure is developed (LPS) at the suction of High Pressure Pump (HPP), it opens the Flush (reject) Solenoid valve for a settable time, ensuring slow flush. After this, the HPP is started for a settable time ensuring fast flush. At the end of this time Flush Solenoid valve is closed and RO is startedoperational. The controller continuously checks the pressure (LPS) at the HPP suction. Should it fall, a message is displayed with an LED indication on the front panel.
View Complete Details

Dc Voltmeter

  • Auxiliary Power 20 to 60 DC, 50 HZ
  • Voltage 0.1 V
  • Input voltage 0.25% ± 1 dgts.
Analog voltmeters are generally galvanometers connected in series with a high-resistance resistor. They have a coiled spring that moves a needle in response to a magnetic field. The needle is next to a graduated scale, allowing the user to take a reading of the current. Such meters are generally less precise than those using improved technology and digital readouts.
View Complete Details

Water Pump Controller

  • Input Supply 3 Phase 415 V, 50 HZ AC
  • Input Current 0-18 phase
  • Display 7 Segment , 4 digit
Water Level Controller is a state of the art instrument to control water pumps. It controls your pump as per levels in the overhead and underground water tanks and also guards your pump against power fluctuations(Over and Under Current)(for 3 Phase Pumps). It is a novel solution, ideal for all your water problems. Pump is Switched On when overhead tank is empty. It is Switched Off when either overhead tank is full or underground tank is empty. Water level controller cum indicator saves water and protects motor and reduces electricity bill. Our Automatic water level controller cum indicator serves 24 hours water supply without letting the overhead tank to become dry.
View Complete Details

Coin Vending Machine

  • Supply voltage 90-270 VAC / DC.
  • Solenoid 12VDC / 230VAC
  • Water Column 1 m (min)
The system comprises of state of the art technology, IP65 panel mounted Water ATM controller, internally mounted Flow Sensor, a 12 VDC (230VAC optional)solenoid valve and suitable piping with convenient external inlet and outlet connections. Water ATM controller has a 2.8 inch LCD display along with 5 nos. of programming keys. This facilitates selection and navigation through the menu driven setting options. The controller also features built in RFID readerwriter, Real Time Clock, Pulse type Flow Sensor interface, control output for Solenoid Valve.
View Complete Details

Atm Card Machine

  • Supply voltage 90-270 VAC / DC
  • Water Inlet Connection 3⁄4” Solvent Cementable
  • Water Column 1 m (min)
The system comprises of state of the art technology, IP65 panel mounted Water ATM controller, internally mounted Flow Sensor, a 12 VDC (230VAC optional)solenoid valve and suitable piping with convenient external inlet and outlet connections. Water ATM controller has a 2.8 inch LCD display along with 5 nos. of programming keys. This facilitates selection and navigation through the menu driven setting options. The controller also features built in RFID readerwriter, Real Time Clock, Pulse type Flow Sensor interface, control output for Solenoid Valve. Automation Philosophy:The Proton Automatic Dispenser, delivers water to an individual by his placing the RFID card (Smart Card) on the Proton ATM Controller on the dispenser panel. Controller opens the solenoid valve to dispense a set batch of water Automatic Dispensing Machine provides for initialising a set of RFID cards and then charging them with an amount to be spent for getting a predefined batches of water. An RFID card can be initialised from the Proton Water ATM controller. A set of RFID cards can be initialised so that they are recognised by a particular set of Proton ATM Controllers only. Thus avoiding inter vendor usage. An individual card then can be charged with an amount in Rupees through the Proton ATM controller. On receiving a batch of water from the Dispenser, an amount set per batch is deducted from the RFID card, as soon as it is presented to the controller. The controller notifies if the water level in the feed tank is low or if the charge left in the card is inadequate. The controller has an auto calibration function, where a unit batch (1 litre) can be calibrated with the help of known capacity containers of 1, 2 , 5 , 10 or 20 litres. Controller stores the data of amount of water dispensed and total charges made, date wise for a period of month.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us