Post Buy Requirement
PT

Prosoft Technology

Verified Add Review

Our Product / Services

  1. Ethernet Device 5 Products available
  2. Network Interface Card

    1 Products available
  3. Gates

    1 Products available
  4. Computer Cables, Adapters & Modules

    1 Products available
  5. Laptops, Computers & Mainframes

    1 Products available
  6. Audio Video System

    1 Products available
  7. Others Products / Services 42 Products / Services available

Other Products / Services

Leading Manufacturer, Supplier & Retailer of ILX69-PBM PROFIBUS DPV1 Master module, PROFIBUS DPV1 Master for CompactLogix, CompactLogix L1 Modbus Serial Module, PROFIBUS DPV1 PS69 Master Network Interface Module and Modbus Slave Network Interface Module.

RLX-IFH9S Radios

The RLX-IFH9S provides powerful and secure wireless serial communications and is well suited for demanding, long-range (up to 30+ miles) SCADA and other serial applications in tough environments. Operating in the license-free 900 MHz band, the RLX-IFH9S penetrates foliage and walls ceilings better than higher frequency radios. With both RS-232 and RS-485 serial ports, serial protocols such as Modbus RTU, DF1, ASCII and DNP3 are supported. The RLX-IFH9S is user configurable as a master, repeater and remote radio and employs the 128 bit AES encryption algorithm approved by the United States government for top secret information. RLX-IFH9S radios are quickly and easily configured using the included, graphical ControlScape software. An OPC server software is also included and allows users to monitor radio network health with any OPC client based HMI software.
View Complete Details

ILX69-PBM PROFIBUS DPV1 Master Module

  • Slaves Maximum 125
  • Input/Output Maximum 244 Bytes per Slave
  • Input Data Maximum 5712 Bytes
  • Acyclic Data DPV1
The ILX69-PBM PROFIBUS DPV1 Master module provides all the advantages of in-chassis PROFIBUS communication, such as the inclusion of an AOI and the Autoscan features which greatly reduce your commissioning time, and ComDTM that provides remote Ethernet connectivity with asset management software. With these modules, CompactLogix processors can easily communicate with slave devices supporting PROFIBUS DPV0 and DPV1 protocol. The module acts as an inputoutput module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.
View Complete Details

PROFIBUS DPV1 Master For CompactLogix

  • Slaves Maximum 125
  • Input/Output Maximum 244 Bytes per Slave
  • Input Data Maximum 5712 Bytes
  • Acyclic Data DPV1
  • Output data Maximum 5760 Bytes
The ILX69-PBM PROFIBUS DPV1 Master module provides all the advantages of in-chassis PROFIBUS communication, such as the inclusion of an AOI and the Autoscan features which greatly reduce your commissioning time, and ComDTM that provides remote Ethernet connectivity with asset management software. With these modules, CompactLogix processors can easily communicate with slave devices supporting PROFIBUS DPV0 and DPV1 protocol. The module acts as an inputoutput module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.
View Complete Details

CompactLogix L1 Modbus Serial Module

  • Features Suitable for SCADA and field device interface applications, Supports up to 1, 000 words of data
  • Configuration Environment RSLogix 5000/Studio 5000
  • I/O Size User selectable 16, 48, or 70 bytes
ProSoft Technologys ILX34-MBS485 module is ideal to connect multiple devices up to 4, 000 feet (1, 219 meters) from your processor. These include SCADA and field device interface applications. The module can be used in CompactLogix L1 processors or Distributed 1734 Point IO systems. In addition, the module can be configured as a Master or Slave.
View Complete Details

PROFIBUS DPV1 PS69 Master Network Interface Module

The PS69 PROFIBUS DP Master module expands the functionality of s CompactLogix MicroLogix family of processors to include PROFIBUS. This module supports both IO control and messaging, thus integrating DPV0 and DPV1 functionality into CompactLogix MicroLogix. The PS69-DPM is a CompactLogix MicroLogix compatible, PROFIBUS certified module, which enables controllers to communicate with a PROFIBUS network. The configuration and diagnostic of the PROFIBUS system is done via the serial diagnostic interface of the module using the System Configuration tool . The data exchange between controller and module is done via the IO process data image using CompactLogix MicroLogix backplane technology.
View Complete Details

Modbus Slave Network Interface Module

  • Dimensions Standard 1769 Single-slot module
  • Current Load 800 mA max @ 5 VDC Power supply distance rating of 2 (L43 and L45 installations on first 2 slots of
  • Operating Temp. 32° F to 140° F (0° C to 60° C)
  • Storage Temp. -40° F to 185° F (-40° C to 85° C)
  • Relative Humidity 5% to 95% (without condensation)
  • LED Indicators Battery and Module Status Application Status Serial Port Activity CFG Port Activity
The MVI69-MCM Modbus MasterSlave Network Interface Module allows Rockwell Automation CompactLogix Programmable Automation Controllers (PACs) and MicroLogix 1769-LRP Programmable Logic Controllers (PLCs) to interface with Modbus-compatible devices. Compatible devices include not only Modicon PLCs but also a wide assortment of third-party devices found in nearly every industry.
View Complete Details

'C' Programmable Application Development Module For CompactLogix

The MVI69 Application Development Module is a CompactLogix backplane compatible module that allows user-developed 'C' applications to operate on the CompactLogix platform. A great way to speed up custom ASCII data communications or to protect a proprietary algorithm, the ADM is a powerful tool for the CompactLogix platform.
View Complete Details

Gas & Liquid Flow Computer For ControlLogix MVI56-AFC

The MVI56 Gas and Liquid Flow Computer Module is a ControlLogix backplane compatible module that allows ControlLogix processors to easily support flow applications performing measurement of hydrocarbon gases or liquids using AGA 3, 7, 8 and API MPMS Chapters 11 and 12 measurement standards. The module calculates flow rates, accumulated volumes, accumulated mass and accumulated energy (heating value). The calculation results are transferred back to the Processor memory for use in the application ladder program or for transfer back to a SCADA host. The MVI56-AFC Gas and Liquid Flow Computer product has been approved by Industry Canada's Measurement for complying with Provisional Specifications and Procedures for the approval of Correction Devices and Linearization Functions Incorporated in Meters and Flow Computers
View Complete Details

Modbus TCP/IP Client/Server Enhanced Network Interface Module For ControlLogix

The MVI56E Modbus TCPIP ClientServer Enhanced Communication Module allows Rockwell Automation ControlLogix processors to interface easily with Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCPIP-compatible instruments and devices. MVI56E enhancements include local and remote configuration and diagnostics through the module's Ethernet port, CIPconnect technology for bridging though Rockwell Automation ControlNet and EtherNetIP networks, and an on-board web server for access to module documentation and sample program files. The MVI56E-MNET and MVI56E-MNETXT are functionally the same. The MVI56E-MNET is designed for standard process applications. The MVI56E-MNETXT is designed for the Logix-XT control platform, allowing it to operate in extreme environments, at higher operating temperatures, and has a conformal coating to protect it from harsh or caustic conditions.
View Complete Details

Fiber-Optic CAN Bus Extenders

  • Features Works with both trunk lines and drop lines, Allows operation at higher speeds for specific distances
  • Specifications Up to 12km fiber lengths , CAN 2A, CAN 2B, and remote frame support
WRC CAN bus Extenders boost signal levels, allowing longer cable lengths, longer trunk lines, and longer drop lines without sacrificing network speed. CAN bus Extenders permit maximum network speed and throughput on CAN, J1939, or DeviceNet network devices, resulting in better control of the process. In addition extenders require no configuration when used in DeviceNet applications as they are configured for autobaud operation Comes with the standard two-year Western Reserve Controls warranty
View Complete Details

CAN Bus Extenders WRC-CANX

  • Features Works with both trunk lines and drop lines, Allows operation at higher speeds for specific distances,
WRC CAN bus Extenders boost signal levels, allowing longer cable lengths, longer trunk lines, and longer drop lines without sacrificing network speed. CAN bus Extenders permit maximum network speed and throughput on CAN, J1939, or DeviceNet network devices, resulting in better control of the process. In addition extenders require no configuration when used in DeviceNet applications as they are configured for autobaud operation. Comes with the standard two-year Western Reserve Controls warranty
View Complete Details

Fisher PROVOX ControlLogix Module CLX-PVX

The Fisher PROVOX module allows an Allen-Bradley ControlLogix processor to control PROVOX IO devices. This module allows a phased migration approach to be used when upgrading or replacing the PROVOX controllers. The gateway provides automatic creation of the PROVOX network scan-list and generates the associated RSLogix 5000 tags reducing engineering effort. Monitor mode allows verification of your conversion logic using live IO data without impacting the running legacy system. Once the new PAC is commissioned the legacy IO can be upgraded one module or one rack at a time as scheduled downtime is available. This module minimizes the risk of excessive downtime when upgrading legacy control systems.
View Complete Details

Honeywell IPC Module

The Honeywell IPC module allows an Allen-Bradley ControlLogix Processor to control a Honeywell IPC 620 IO devices. This module allows a phased migration approach to be used when upgrading or replacing Honeywells SLM 621-9939 Scanners. This In-chassis module provides automatic detection of the IPC IO racks and modules. After the direction of the IO cards has been entered the associated RSLogix 5000 tags can be auto generated significantly reducing engineering effort. Monitor mode allows verification of your conversion logic using live IO data without impacting the running legacy system. Once the new processor is commissioned the legacy IO can be upgraded one module or one rack at a time as scheduled downtime is available. This module minimizes the risk of excessive downtime when upgrading legacy control systems.
View Complete Details

Modbus TCP Server Enhanced Network Interface Module

  • Specifications Backward compatible with previous MVI56-MNETC versions, Single-slot 1756 ControlLogix backplane compatible
When you need Modbus TCPIP communications, the MVI56E- MNETCMNETCXT is the module of choice. The Modbus TCPIP Enhanced Communications Module allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily with Modicon Programmable Automation Controller (PACs), as well as multiple Modbus TCPIP server-compatible instruments and devices. The multi-client module improves performance when controlling multiple servers on a Modbus TCPIP network, by supporting up to 30 Clients. It also supports up to 20 server connections providing the ability to communicate with other DCS and SCADA systems. Both client and server functionality can run simultaneously, allowing the module to operate as a powerful data concentrator. The MVI56E-MNETC and MVI56E-MNETCXT are functionally the same. The MVI56E-MNETC is designed for standard process applications. The MVI56E- MNETCXT is designed for the Logix-XT control platform, allowing it to operate in extreme environments. It tolerates higher operating temperatures, and has a conformal coating to protect it from harsh or caustic conditions. MVI56E enhancements include configuration and management through the modules Ethernet port, and CIPconnect technology for bridging though ControlNet and EtherNetIP networks.
View Complete Details

Modbus Master/Slave Enhanced Network Interface Module For ControlLogix

The MVI56E Communication Module allows for Modbus Master andor Slave connectivity from Rockwell Automation ControlLogix processors to Modbus RTUASCII devices. Each MVI56E port can be configured as a Master or Slave. The MVI56E-MCM and MVI56E-MCMXT act as inputoutput modules on the ControlLogix backplane, making Modbus data appear as IO data to the processor. Two independently configurable serial ports can operate on the same or different Modbus networks. The MVI56E-MCM is designed for standard process applications and the MVI56E-MCMXT is designed for the Logix-XT control platform, allowing it to operate in extreme environments. It can tolerate higher operating temperatures, and has conformal coating to protect it from harsh or caustic conditions.
View Complete Details

BM-xx00-RM1K Wireless IO Radio Kit

  • Feature Save time and money: Eliminates trenching and running conduit / deploys in minutes, Easy to use: No software configuration needed
  • DIN Rail Mounting Compatibility 35 mm x 7.5 mm DIN Rail
  • DataRailâ„¢ (Included with Radio Kit) 6.1 in / 156 mm - Supports up five (5) I/O modules, other lengths also available
  • Built-In Mounting Hardware Spring-loaded clip-on system
How many times do you need to get a few points of digital or analog inputs and outputs from point A to point B, but cant justify the cost of running the wires? The Radio Kit is a replacement for hardwired IO that is simple to deploy. The Kit requires no programming just wire strippers and a screwdriver. There is no communication protocol to interpret. The radios are paired and secured at the factory, so there are no settings or configurations to figure out. It is bi-directional, so digital and analog signals can be sent in both directions between two connected IO stations. Inputs on one module are simply replicated as outputs on the corresponding module. Our wireless IO makes use of the unlicensed ISM band at either 868 MHz, 900 MHz, or 2.4 GHz (USA only). The radios can send IO up to 4 miles for the 900 MHz or 1 mile for the 868 MHz and 2.4 GHz models. Each radio pair can connect up to 16 IO modules, more than enough for most applications.
View Complete Details

Multi-Point Wireless I O Radio Kit

  • Features Single power termination per station saves wiring time., AES encryption ensures data is protected from intrusions
  • Device Functionality Multipoint Wireless I/O Gateway
  • Embedded Controller 32-bit Low Power ARM7 Microcontroller with Internal FLASH (Field Upgradeable)
ProSoft Technologys Multi-Point Wireless IO system allows you to monitor IO from multiple locations without running long wires. This secure, reliable system is scalable and deploys quickly, allowing you to skip trenching, conduit, and permits. Three module types: Analog 0-10 V, Analog 4-20 mA, and DigitalDiscrete give you the freedom to customize your setup based on your environment and needs. The system can be used in different methods: IO to IO, IO to Modbus serial communications, and Modbus serial to Modbus Serial communications. This peer-to-peer system can move data from the IO or Modbus devices to any other node. The digital input module can act as a counter and send the accumulated value to another location.
View Complete Details

Multi-Point Wireless Input Output Radio Kit

ProSoft Technologys Multi-Point Wireless IO system allows you to monitor IO from multiple locations without running long wires. This secure, reliable system is scalable and deploys quickly, allowing you to skip trenching, conduit, and permits. Three module types: Analog 0-10 V, Analog 4-20 mA, and DigitalDiscrete give you the freedom to customize your setup based on your environment and needs. The system can be used in different methods: IO to IO, IO to Modbus serial communications, and Modbus serial to Modbus Serial communications. This peer-to-peer system can move data from the IO or Modbus devices to any other node. The digital input module can act as a counter and send the accumulated value to another location.
View Complete Details

Analog I O V Module

The analog 0-10 V IO module provides two 24-bit inputs and two 16-bit outputs. The IO modules offer 2500 V r.m.s. isolation, with a wide operating temperature range and Class I Division 2 hazardous location rating, making them ideal for demanding industrial installations. Connect them to the wireless IO radios for point-to-point wire replacement applications, or to the RS485 IO Extension module to add IO to a Modbus network.
View Complete Details

Bristol Babcock Serial Slave Module MVI56-BSAPS

  • Operating Temperature 0 to 60°C (32 to 140°F)
  • Storage Temperature Storage Temperature
  • Backplane Current Load 800 mA @ 5 V
The MVI56 Bristol Babcock Serial Slave Module allows Rockwell Automation ControlLogix IO compatible processors to interface easily with Bristol Babcock Serial communication devices.
View Complete Details

PSW-AFC ProSoft AFC Manager Monitoring Tool

  • Features Monitor the meter operation , Perform an audit scan , Configure the archives
  • Number of meter channels: 8 or 16 meters (depending on module capabilities)
  • Meter types: Differential (orifice, V-cone), Linear (pulse train), Flow rate integration, Pulse freq
The AFC Manager is an easy-to-use Windows 98NT2000XP based configuration, reporting, and monitoring tool provided with the AFC modules. Project configurations may be uploaded, downloaded and saved to the PC under user selectable file names.
View Complete Details

PSW-PCB ProSoft Configuration Builder Software

  • Features . Create plant-wide configurations of all ProSoft Technology products. Manage configuration of complex protocols and networks, including PROFIBUS DP.
Use a single software tool to configure and test all ProLinx modules, as well as a growing selection of ProSoft inRAx and ProTalk modules. ProSoft Configuration Builder simplifies the task of managing the configuration files that control how your ProSoft module operates. ProSoft Configuration Builder also provides the following features: Graphical User Interface replaces the Hyperterminal download and monitor method.Provides error reduction in setting up configuration files.Extensive online help for module-specific configuration options.
View Complete Details

PSW-PWD ProSoft Wireless Designer Software

  • Features Visual diagram of site layout Location (latitude/longitude, based on GPS coordinates)
  • Specifications Checks wireless link feasibility based on path length and recommended accessories, Predicts signal st
ProSoft Wireless Designer simplifies the task of planning and specifying your ProSoft Wireless network. The easy to use, wizard-based interface creates a visual layout of your radios and sites, and generates a complete Bill of Materials including radios and accessories.
View Complete Details

CLX-APACS Module

  • Features Supports all standard APACS+ digital and analog I/O modules, Supports up to 39 IO Bus cards per network segment
  • Ports Dual Channel, Redundant Serial RS-485
  • Typical Power Consumption 5 mA @ 24 VDC and 450 mA @ 5.1 VDC
The CLX-APACS module enables a ControlLogix Plant-PAx system to control MooreSiemens APACS+ IO Bus remote IO racks. This provides the ability to execute a phased migration of old Moore APACS DCS systems.
View Complete Details

Modbus TCP/IP Multi Client Enhanced Network Interface Module

The MVI56E Modbus TCPIP Multi Client Enhanced Communication Module for Remote Chassis allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily with multiple Modbus TCPIP server-compatible instruments and devices. The Multi Client module improves performance when controlling multiple servers on a Modbus TCPIP network, by supporting up to 30 clients.MVI56E enhancements include configuration and management through the module Ethernet port, CIPconnect technology for bridging through ControlNet and EtherNetIP networks, and has a web server to access on-board documentation, Add-On Instructions, and sample program files.This module uses a small IO data image for transfer of data between the module and the ControlLogix processor, making it ideal for ControlNet or Ethernet applications with the module in a remote rack.
View Complete Details

Linux Development Module

The MVI69E-LDM module allows users to develop and deploy CC++ custom algorithm applications for CompactLogix systems. Users are also able to create drivers for specialty Ethernet and Serial end-devices. The Linux Development module comes with a built-in API for backplane communications to the processor. With the separate development kit DVD, you are the developer who controls exactly what this module can and cannot do.
View Complete Details

Linux Development Module For CompactLogix MVI69E-LDM

  • Slaves Maximum 125
  • Input/Output Maximum 244 Bytes per Slave
  • Input Data Maximum 5712 Bytes
  • Acyclic Data DPV1
The MVI69E-LDM module allows users to develop and deploy CC++ custom algorithm applications for CompactLogix systems. Users are also able to create drivers for specialty Ethernet and Serial end-devices. The Linux Development module comes with a built-in API for backplane communications to the processor. With the separate development kit DVD, you are the developer who controls exactly what this module can and cannot do.
View Complete Details

IEC 60870-5-103 Master Network Interface Module For ControlLogix MVI56-103M

The MVI56 IEC 60870-5-103 Master Network Interface Module allows ControlLogix processors to interface easily with IEC 60870-5-103 Slave devices. The MVI56-103M module interfaces up to 32 serial communication devices with the ControlLogix processor. Two communication ports on the module act as controlling devices (Masters) to interface with controlled devices on their own networks. Each port is individually configurable. The MVI56-103M is the ideal solution for many applications where IEC-compatible devices must communicate with the ControlLogix platform. Compatible devices include relays, breakers, sub-station communication modules and other serial communication devices. Functionality of the IEC protocol is very similar to the DNP 3.0 protocol which features time stamping and True Report by Exception (TRBE). These features allow the MVI56-103M module to send a report to the processor without being polled, providing real time data transmission in critical situations.
View Complete Details

IEC 60870-5-101 Master Network Interface Module For ControlLogix

The MVI56 IEC 60870-5-101 Master Network Interface Module allows ControlLogix processors to interface easily with IEC 60870-5-101 Slave devices. The MVI56-101M module interfaces up to 32 serial communication devices with the ControlLogix processor. Two communication ports on the module act as controlling devices (Masters) to interface with controlled devices on their own networks. Each port is individually configurable. The MVI56-101M is the ideal solution for many applications where IEC-compatible devices must communicate with the ControlLogix platform. Compatible devices include relays, breakers, sub-station communication modules and other serial communication devices. Functionality of the IEC protocol is very similar to the DNP 3.0 protocol which features time stamping and True Report by Exception (TRBE). These features allow the MVI56-101M module to send a report to the processor without being polled, providing real time data transmission in critical situations.
View Complete Details

HART Master Multi-drop Network Interface Module For ControlLogix

The MVI56-HART Master Multi-drop Network Interface Module allows ControlLogix IO compatible processors to easily communicate with HART slave devices. The MVI56-HART module interfaces up to 15 devices on each HART channel with the ControlLogix processor. Four channels on the module support master protocol commands to interface with slave devices on their own networks. Each port is individually configurable. Data is exchanged between the HART network and the ControlLogix processor using the internal database contained in the module and direct control by the processor's ladder logic and pre-defined data objects (5000 registers maximum).The MVI56-HART module is the perfect solution for industrial applications in chemical and refining operations, gas and liquid distribution systems, and remote offshore monitoring stations, addressing virtually all aspects of control, data acquisition, and maintenance.
View Complete Details

IEC 60870-5-103 Master Network Interface Module For ControlLogix

The MVI56 IEC 60870-5-103 Master Network Interface Module allows ControlLogix processors to interface easily with IEC 60870-5-103 Slave devices. The MVI56-103M module interfaces up to 32 serial communication devices with the ControlLogix processor. Two communication ports on the module act as controlling devices (Masters) to interface with controlled devices on their own networks. Each port is individually configurable. The MVI56-103M is the ideal solution for many applications where IEC-compatible devices must communicate with the ControlLogix platform. Compatible devices include relays, breakers, sub-station communication modules and other serial communication devices. Functionality of the IEC protocol is very similar to the DNP 3.0 protocol which features time stamping and True Report by Exception (TRBE). These features allow the MVI56-103M module to send a report to the processor without being polled, providing real time data transmission in critical situations.
View Complete Details

HART Master Multi-drop Network Interface Module

The MVI56-HART Master Multi-drop Network Interface Module allows ControlLogix IO compatible processors to easily communicate with HART slave devices. The MVI56-HART module interfaces up to 15 devices on each HART channel with the ControlLogix processor. Four channels on the module support master protocol commands to interface with slave devices on their own networks. Each port is individually configurable. Data is exchanged between the HART network and the ControlLogix processor using the internal database contained in the module and direct control by the processor's ladder logic and pre-defined data objects (5000 registers maximum).The MVI56-HART module is the perfect solution for industrial applications in chemical and refining operations, gas and liquid distribution systems, and remote offshore monitoring stations, addressing virtually all aspects of control, data acquisition, and maintenance.
View Complete Details

DF1 Master/Slave Network Interface Module With Reduced Data Block For ControlLogix

MVI56-DFCMR When needing additional DF1 ports in your ControlLogix system, the MVI56-DFCM Network Interface Module is the fastest and easiest way to add DF1 HalfFull Duplex Master and Slave capability. This module has two powerful and fully configurable DF1 ports allowing the many SCADA and field devices supporting the DF1 protocol to be integrated into the ControlLogix platform. Devices commonly supporting the protocol include Rockwell Automation PLCs and power monitoring equipment, as well as several other third party devices. Each port is user-configurable to act as a Master or as a slave.
View Complete Details

Limitorque Valve Network Interface Module

MVI56-LTQ The MVI56 Limitorque Valve Actuator Master Network Interface Module allows Rockwell Automation ControlLogix processors to interface easily with Limitorque Valve Actuators and other Limitorque protocol compatible devices.
View Complete Details

Siemens 3964R Network Interface Module

  • Feature The 3964R protocol was designed by Siemens for bidirectional data communication through a point-to-point connection
  • Single Slot - 1769 backplane compatible
The module is ideal in control configurations where there is a need for the CompactLogix processor to exchange data with other non-Rockwell Automation control devices in low speed applications. The MVI69-S3964R can communicate with devices using two RS-232, RS-422 communication lines (ports). The ports operate independently from each other.
View Complete Details

IEC 60870-5-101 Master Network Interface Module For CompactLogix

The MVI69 IEC 60870-5-101 Master Network Interface Module allows CompactLogix processors to interface easily with IEC 60870-5-101 Slave devices. The MVI69-101M module interfaces up to 32 serial communication devices with the CompactLogix processor. Two communication ports on the module act as controlling devices (Masters) to interface with controlled devices on their own networks. Each port is individually configurable. The MVI69-101M is the ideal solution for many applications where IEC-compatible devices must communicate with the ControlLogix platform. Compatible devices include relays, breakers, sub-station communication modules and other serial communication devices. Functionality of the IEC protocol is very similar to the DNP 3.0 protocol which features time stamping and True Report by Exception (TRBE). These features allow the MVI69-101M module to send a report to the processor without being polled, providing real time data transmission in critical situations.
View Complete Details

DF1 Master/Slave Network Interface Module For CompactLogix

The MVI69-DFCM DF1 MasterSlave Communication Module allows Rockwell Automation CompactLogix MicroLogix compatible processors to interface easily with DF1 protocol compatible devices and hosts. Devices commonly supporting the protocol include Rockwell Automation PLCs and power monitoring equipment, as well as several other third party devices in the marketplace. The MVI69-DFCM module has two Application Serial ports supporting the DF1 protocol, with each port user-configurable to act as a Master or as a slave. Data transfer between the module and the CompactLogix MicroLogix processor is asynchronous to the DF1 network, with the modules internal database being used to exchange data between the processor and the DF1 network.
View Complete Details

IP Client Server Network Interface Module

MVI46-MNET The MVI46 Modbus TCPIP Network Interface Module is designed to allow SLC processors to interface easily with other Modbus TCPIP protocol-compatible devices using client and server functionality. Compatible devices include not only Modicon processors (which support the Modbus TCPIP protocol) but also a wide assortment of other clients and server devices.
View Complete Details

Modbus Plus Dual Port Network Interface Module

The MVI46 Modbus Plus Dual Port Network Interface Module allow Rockwell Automation SLC processors to connect directly on Modbus Plus networks as a peer. The module acts as an inputoutput module between the Modbus Plus network and the processor. Compatible devices can be found in most industries and include devices such as drives, relays and power monitor hardware.
View Complete Details

ILX69 PROFIBUS Slave Module

  • Features Rockwell Automation Encompass Approved PI Certified Remote diagnostics via Ethernet
  • PROFIBUS DP Cyclic Data 244 Bytes IN / 244 Bytes OUT
  • Acyclic Read/Writes 240 Bytes
The ILX69 PROFIBUS Slave module is an in-chassis PROFIBUS DPV1 Slave for CompactLogix, supporting cyclic PROFIBUS IO data and acyclic messaging. Explicit ladder logic CIP message blocks provide slave status diagnostic data and the ability for acyclic messaging.The ILX69 interface appears to the CompactLogix controller as a standard IO module allowing it to be configured via StudioRSLogix5000. The cyclic PROFIBUS IO data can be configured in StudioRSLogix 5000, or configuration can be transferred from the Master to the slave module. The Ethernet interface allows for remote diagnostic and troubleshooting. Complete program examples for simple and quick start-up are available.
View Complete Details

PROFIBUS DPV1 Slave For CompactLogix

The ILX69 PROFIBUS Slave module is an in-chassis PROFIBUS DPV1 Slave for CompactLogix, supporting cyclic PROFIBUS IO data and acyclic messaging. Explicit ladder logic CIP message blocks provide slave status diagnostic data and the ability for acyclic messaging.The ILX69 interface appears to the CompactLogix controller as a standard IO module allowing it to be configured via StudioRSLogix5000. The cyclic PROFIBUS IO data can be configured in StudioRSLogix 5000, or configuration can be transferred from the Master to the slave module. The Ethernet interface allows for remote diagnostic and troubleshooting. Complete program examples for simple and quick start-up are available.
View Complete Details

Modbus Plus Dual Port Network Interface Module

  • Feature Foreign device data concentrator, Pipelines and offshore platforms
  • Single Slot - 1756 backplane compatible
The MVI56 Modbus Plus Dual Port Network Interface Module allow Rockwell Automation ControlLogix processors to connect directly on Modbus Plus networks as a peer. The module acts as an inputoutput module between the Modbus Plus network and the processor. Compatible devices can be found in most industries and include devices such as drives, relays and power monitor hardware.Compatible devices include not only Modicon PLCs (which all support the Modbus Plus protocol) but also a wide assortment of end devices licensed through the ModConnect Program. The MVI56-MBP module acts as an inputoutput module between the Modbus Plus network and the Rockwell Automation backplane. The data transfer from the ControlLogix processor is asynchronous from the actions on the Modbus Plus network. A 4000-word register space in the module exchanges data between the processor and the Modbus Plus network. These modules allow Rockwell Automation platforms to connect directly on Modbus Plus networks as a peer. In addition, the modules act as slaves to processors that must readwrite data from the module's memory. Crossing all industrial boundaries, potential applications include the connection of Rockwell Automation processors to Modicon processors, and the connection of Modbus Plus speaking devices such as drives, relays, and power monitor hardware to the Rockwell Automation backplanes.
View Complete Details

Modbus Plus Dual Port Network Interface Module For ControlLogix

The MVI56 Modbus Plus Dual Port Network Interface Module allow Rockwell Automation ControlLogix processors to connect directly on Modbus Plus networks as a peer. The module acts as an inputoutput module between the Modbus Plus network and the processor. Compatible devices can be found in most industries and include devices such as drives, relays and power monitor hardware.
View Complete Details

Message Manager For Industrial Communication ILX56-MM

  • Features The Message Manager acts as a communication interface as well as a message transaction engine
  • Specifications Built-in web based configuration utility, Local or Remote rack
The ProSoft Technology inRAx Message Manager is a single-slot solution that connects and transfers Factory and Plant Process Automation monitoring and control data between islands of automation across diverse platforms, networks and protocols. The inRAx Message Manager is an easy-to-use data transfer engine for the ControlLogix 1756 platform, supporting Rockwell Automation Programmable Logic Controller (PLC) and Programmable Automation Controller (PAC) network protocols, as well as platforms and devices that use Siemens Industrial Ethernet and Modbus TCPIP protocols. The ILX56-MM makes it easy for System Integrators and End Users to reduce the engineering effort required to coordinate data transfers between multiple control systems in Factory and Plant Automation applications. The Message Manager simplifies and streamlines data connection and transfer operations by enabling PLCPAC data exchanges without the need for additional message-specific PLC programming.
View Complete Details

Industrial Cellular Gateway ICX35-HWC

  • Features EtherNet/IP object support. Your PAC/PLC can easily read diagnostic data from the gateway, Supports SMS messaging with EtherNet/IP controller
  • Cellular Technology LTE, GSM, UMTS/HSPA+, GPRS, EDGE, CDMA
The ICX35-HWC Industrial Cellular Gateway is the ideal communication solution for system integrators and OEMs that have to monitor devices that are in hard-to-reach spots. With the gateway, they can monitor and troubleshoot their devices from anywhere in the world over 4G LTE cellular connections, with fallback to 3G. This ensures clear communications and longevity for the application. An EtherNetIP controller can send a message to the gateway, and read diagnostic data like signal strength, data usage, and more, allowing the user to avoid time-consuming and costly site visits. The industrial cellular gateway can also be monitored through ProSoft Connect, ProSoft Technologys secure, cloud-native platform for the Industrial Internet of Things. This service can be accessed anywhere in the world, offering the user an intuitive Web interface from which they can monitor their automation devices in real time.
View Complete Details

BM-D100-144x I/O Module

  • Feature Easy to use: No software configuration needed, Easy to install: Mounts onto a 35 mm DIN rail without any tools
  • DIN Rail Mounting Compatibility 35 mm x 7.5 mm DIN Rail
  • I/O Module Slave ID Selection 16-Position Rotary Switch
The digital IO modules provide four inputs and four solid state outputs. The IO modules offer 2500 V r.m.s. isolation, with a wide operating temperature range and Class I Division 2 hazardous location rating, making them ideal for demanding industrial installations. Connect them to the wireless IO radios for point-to-point wire replacement applications, or to the RS485 IO Extension module to add IO to a Modbus network.
View Complete Details

FL-Net Network Interface Module For CompactLogix MVI69-FLN

The MVI69-FLN FA Control Network communication module is a single-slot solution that allows Rockwell Automation CompactLogix processors to communicate with FL-net protocol-compatible devices. The module implements the FL-net version 2.00 (OPCN-2) specification, as defined by JEMA (The Japan Electrical Manufacturers Association) for the standard FA control network. FL-net is a master-less system. The MVI69-FLN module acts as a gateway between the FL-net network and the CompactLogixMicroLogix backplane. The data transfer from the CompactLogixMicroLogix processor is asynchronous from the actions on the FL-net network. The modules internal database can be used to exchange Area 1 and Area 2 cyclic, network, and module status data between the processor and the FL-net network. FL-net is a peer-to-peer networking system. All FL-net devices transfer data using two shared databases with fixed sizes. The MVI69-FLN module accepts commands to control and monitor the data stored in these two databases. This data is passed between the module and the CompactLogixMicroLogix processor over the backplane for use in customer applications.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us