    Manual Stainless Steel DLP Temperature Data Logger, For Industrial, Building Automation, Certification : YAS

    • MaterialStainless Steel
    • Brand NameDWYER USA
    • CertificationYAS
    • Weight12 oz (340 g).
    • Supply TypeManufacturer, Exporter, Supplier, Retailer, Distributor, Importer, Trader, Buying House
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 15 Years
    • building Nature of Business Supplier
    • gst icon GST No. 07AOSPS8386M1ZM

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • TypeTemperature Data Logger
    • MaterialStainless Steel
    • CertificationYAS
    • Weight12 oz (340 g).
    • ColorGrey, White
    • ConditionNew
    • ApplicationIndustrial, Building automation
    • FeatureLight Weight
    • Warranty1Year
    • AccuracyTemperature: ±0.9°F (±0.5°C); Pressure: 2% FSR, 0.25% at 77°F (25°C) typical.
    • Automation GradeManual
    • Brand NameDWYER USA

    DLP Temperature Data Logger

    Series DLP Pressure/Temperature Data Logger

    1/4" NPT Fitting, Up to 5000 psia

    The Series DLP Data Logger can record pressure and temperature. The 1/4" NPT fitting comes standard and allows the logger to be adapted to almost any pressure fitting. The internal temperature sensor provides accurate temperature measurements without the need of a separate temperature recorder, and many of the models provide a choice between measuring pressure in psia or psig. The DLP can easily be started and stopped from a PC or delayed to start up to six months in advance. The battery-powered data logger can store over 16,000 measurements per channel, and the easy to use DL700 software makes retrieving data simple.

    Product Applications

    • Building automation
    • Clean room
    • Operating rooms
    • Process applicationsLabs
    • Regulated environments

                  ModelDescription

    • DLP-A08Pressure/temperature data logger, range 0-30 psia.
    • DLP-A10Pressure/temperature data logger, range 0-100 psia.
    • DLP-A13Pressure/temperature data logger, range 0-300 psia.
    • DLP-A14Pressure/temperature data logger, range 0-500 psia.
    • DLP-A15Pressure/temperature data logger, range 0-1000 psia.
    • DLP-A19Pressure/temperature data logger, range 0-5000 psia.
    • DLP-G08Pressure/temperature data logger, range 0-30 psig.
    • DLP-G10Pressure/temperature data logger, range 0-100 psig.
    • DLP-G13Pressure/temperature data logger, range 0-300 psig.
    • DLP-G14Pressure/temperature data logger, range 0-500 psig.

    Specifications

    • Range:Temperature: -40 to 176°F (-40 to 80°C); Pressure: 0 to 30 psia(g), 0 to 100 psia(g), 0 to 300 psia(g), 0 to 500 psia(g), 0 to 1000 psia, and 0 to 5000 psia depending on the model.
    • Memory Size:16,383 readings per channel.
    • Accuracy:Temperature: ±0.9°F (±0.5°C); Pressure: 2% FSR, 0.25% at 77°F (25°C) typical.
    • Resolution:Temperature: 0.2°F (0.1°C); Pressure: 0.002 psia(g), 0.005 psia(g), 0.05 psia(g), 0.05 psia, and 0.2 psia depending on the model.
    • Sampling Method:Stop on memory full.
    • Sampling Rate:Selectable from 2 sec to 12 hrs.
    • Computer Requirements:Windows® 95, Windows® 98, Windows® 2000, Windows® ME, Windows NT®, and Windows® XP operating system, one free USB port.
    • Power Requirements:3.6 V TL2150 lithium metal battery, installed functional, user replaceable.
    • Battery Life:1 yr (approx).
    • Interface:USB port (interface cable required).
    • Material:Stainless steel.
    • Weight:12 oz (340 g).
    • Agency Approvals:CE.

    Features

    • Efficient data capture tool to review processes are running correctly or to analyze alarm and out-of-spec conditions
    • Battery-powered reduces need to hard wire power allowing device to be used in a as a tool in a variety of in-and-out testing
    • PC start and stopping allows centralized control of data collection

    Accessories

    Model NumberDescription

    • DL700Software, manual and USB interface cable(6').
    • TL-2150Replacement battery.

     

     


    Additional Information

    • Payment Terms L/C, D/A, D/P, T/T, Western Union
    • Port of DispatchDELHI
    • Delivery Time4-6 WEEK
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry

    Product Images

    • DLP Temperature Data Logger
    • DLP Temperature Data Logger
    • DLP Temperature Data Logger
    • DLP Temperature Data Logger
    • DLP Temperature Data Logger
    • DLP Temperature Data Logger
    • DLP Temperature Data Logger
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for DLP Temperature Data Logger?

    Quantity
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice