Immersion Heater, Certification : U2, ATEX, IEC Ex, CCOE, etc)

Listing ID #4833555

  • CertificationWill be provided based on Requirement. ( U, U2, ATEX, IEC Ex, CCOE, etc)
  • Design Temperature-40 deg C to 650 degrees C
  • Element Outer SheathSS , Alloy 600 series, Alloy 800 series, Hastelloy, Titanium, copper etc
  • Design PressureUp to 350 bar(g)
  • Supply Type Manufacturer, Exporter
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 7 Years
  • Nature of Business Retailer
  • GST No. 08AAACT5482C1ZF

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Certification Will be provided based on Requirement. ( U, U2, ATEX, IEC Ex, CCOE, etc)
  • Terminal Enclosure As required (Weatherproof or Flameproof)
  • Rating From 0.1 1kW to 5000kW (Max) in Single Bundle or combination
  • Installation Horizontal / Vertical / direct / indirect
  • Design Pressure Up to 350 bar(g)
  • Element Outer Sheath SS , Alloy 600 series, Alloy 800 series, Hastelloy, Titanium, copper etc
  • Design Temperature -40 deg C to 650 degrees C
  • Control System Thermostat control / Contactor control / Thyristor control / combination

For any Production/process facility, when a large volume of fluid to be heated before pumping out to process application, the Immersion Heaters are always the best-recommended solutions. A single bundle or multiple smaller units can be installed in the Tank for the uniform heat transfer and steady heating of the fluid with all safety precautions in built within the heater and control system.
Some of the precautions to be taken while designing and selecting an Immersion heater are

  • Selection of right material for the wet parts to avoid potential corrosion from the fluid to be heated.
  • Proper cold length & active length ratio to avoid hot spots & dry heating.
  • Element skin temperature within flash point limit of the fluid to avoid any hazard. A Proper thermal design is very much necessary whenever heating a flammable fluid or in hazardous area installation.
  • Fixing method & support for the bundle considering the turbulence during the in & outflow.
  • Control system for both element skin & fluid temperature.


Construction
Terminal Enclosure: Marathon flameproof heaters are certified to install in hazardous area Zone 1 & 2 , Gas group IIC, IP66. The Terminal enclosure is designed to protect the terminals of the individual elements from external impacts, such as dust, moisture etc and to facilitate the connection of the Incoming power supply to the heater bundle.
Heater Bundle: Consist of No. of U Pin heating elements adequately supported by set of Baffles & Tie rods, designed to deliver the specified temperature at outlet by maintaining the element temperature & pressure drop within the safe limits. Heating elements can be fixed to heater flange by means of standoff sleeve pipes with brazing or by direct welding or by means of threaded couplings. Heat duty of a bundle can be divided in to many sub groups (banks) based on process conditions. This will help in better control as flexibility in the operation.
Temperature Sensors: The Heater bundle will have Element skin temperature sensor for monitoring and regulating the Element skin temperature within the limits. The Unit may also need additional sensors such as Tube sheet Temperature Sensor, Terminal Box Sensor, vessel Body temperature sensor and process fluid Temperature sensors based on case to case. The Sensors used for the system will be certified in accordance with the area of installation. The Temperature sensors are Typically RTD or Thermocouple. A simple heater bundle can also be controlled using Thermostat protection for skin & process temperature. If the Operation pressure is High, It is recommended to have a PSV (Pressure safety Valve) installed within the Heater Vessel as an additional safety measure.
Control Panel: Heater controls Panel are designed to monitor & control the operations of the heater bundle also to ensure the safety of the equipment and operations. The control logic can be either ON/OFF (contactor) or regulated (Thyristor) or combination of both in a single panel. The control panels can be installed in both safe area & hazardous area by following respective design guidelines & certification requirements. The Control Panels are provided with various indication systems such as Power ON, Heater ON OFF, Trip, High Temperature etc for comfortable handling of the process. The Temperatures of Elements, Process fluid & other areas (with sensors) are displayed on the Panel for better monitoring & awareness. Control Panel will also have safety interlocks such as high element temperature, Earth fault, process over temperature etc along with Emergency stop access for the safe operation and control.
Advantages

  • Heaters can be used for quick heating of small volume storages as well as for heating large volumes with longer operational hours
  • Widely used for heating high viscous fluids ( Bitumen, HFO etc) and reduce the viscosity before pumping out
  • Environment-friendly design. No hazardous gas/smoke/ emission from the system.
  • Precision Temperature control
  • Can be accommodated in small footprints.
  • Custom designed to meet specifications.
  • Highly energy efficient and provide maximum dielectric strength.
  • Compatible with standard industry piping and safety standards.
  • Reliable design.
  • Easy to operate and maintenance-friendly.
  • Energy Saving.
  • No need to drain the tank for any repair/replacements in case of indirect Immersion Heaters.
  • Heating Elements: Mineral filled insulated Heating Elements or Tubular heating Elements with Ni-Cr (80-20) as heating Coil and suitable outer sheaths.
  • Protections & control: Element Skin Temperature Control, Process Temperature Control, Earth Leakage Protection Overload Current Protection, Temperature Class Protection ( for Hazardous area only)


Application

  • At large Storage Tanks for preheating of thick fluids.
  • Oil Heating (crude, Thermic fluids, and other Process fluids etc in storage tanks).
  • Water heating applications & vaporizer System.
  • For reducing the viscosity of the fluid and make it suitable for pumping out.
  • Steam Boilers.
  • Oil cooling systems & compression packages
  • Edible oil heating for food industries.


Additional Information

  • Payment Terms T/T
  • Port of Dispatch Mumbai
  • Packaging Details Wooden Box Case
  • Delivery Time 6-8 Weeks
Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

Tempsens Instruments (I) Pvt. Ltd. is one of the largest provider for Thermal and Cables Solutions. The headquarters are based in India with production units in Germany and Indonesia. It's a part of Pyrotech group of companies founded in 1976. All companies are ISO 9001, ISO 14001 and OHSAS 18001 certified company with NABL accredited laboratory.
The products offered are Thermocouples, RTDs, Thermowells, Instrumentation and Control cables & wires Signal , Temperature Calibration Equipments, Pyrometers, Industrial heaters, Furnaces and related accessories. Accredited Calibration services are provided for all kind of temperature sensors and furnaces including pyrometers for temperature range -196°C to 2700°C.
Tempsens supply to more than 70 countries; and services customer through dedicated offices or distributors.
  • Nature of Business Manufacturer / Exporter / Service Provider / Supplier / Retailer / Trader
  • Number of Employees 500 - 650
  • Year of Establishment 1976
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Immersion Heater?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Immersion Heater, Certification : U2, ATEX, IEC Ex, CCOE, etc) at Best Price in Udaipur
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Immersion Heater, Certification : U2, ATEX, IEC Ex, CCOE, etc)

Listing ID #4833555

  • CertificationWill be provided based on Requirement. ( U, U2, ATEX, IEC Ex, CCOE, etc)
  • InstallationHorizontal / Vertical / direct / indirect
  • Design PressureUp to 350 bar(g)
  • RatingFrom 0.1 1kW to 5000kW (Max) in Single Bundle or combination
  • Supply Type Manufacturer, Exporter
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 7 Years
  • Nature of Business Retailer
  • GST No. 08AAACT5482C1ZF

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Certification Will be provided based on Requirement. ( U, U2, ATEX, IEC Ex, CCOE, etc)
  • Design Temperature -40 deg C to 650 degrees C
  • Rating From 0.1 1kW to 5000kW (Max) in Single Bundle or combination
  • Control System Thermostat control / Contactor control / Thyristor control / combination
  • Element Outer Sheath SS , Alloy 600 series, Alloy 800 series, Hastelloy, Titanium, copper etc
  • Design Pressure Up to 350 bar(g)
  • Installation Horizontal / Vertical / direct / indirect
  • Terminal Enclosure As required (Weatherproof or Flameproof)

For any Production/process facility, when a large volume of fluid to be heated before pumping out to process application, the Immersion Heaters are always the best-recommended solutions. A single bundle or multiple smaller units can be installed in the Tank for the uniform heat transfer and steady heating of the fluid with all safety precautions in built within the heater and control system.
Some of the precautions to be taken while designing and selecting an Immersion heater are

  • Selection of right material for the wet parts to avoid potential corrosion from the fluid to be heated.
  • Proper cold length & active length ratio to avoid hot spots & dry heating.
  • Element skin temperature within flash point limit of the fluid to avoid any hazard. A Proper thermal design is very much necessary whenever heating a flammable fluid or in hazardous area installation.
  • Fixing method & support for the bundle considering the turbulence during the in & outflow.
  • Control system for both element skin & fluid temperature.


Construction
Terminal Enclosure: Marathon flameproof heaters are certified to install in hazardous area Zone 1 & 2 , Gas group IIC, IP66. The Terminal enclosure is designed to protect the terminals of the individual elements from external impacts, such as dust, moisture etc and to facilitate the connection of the Incoming power supply to the heater bundle.
Heater Bundle: Consist of No. of U Pin heating elements adequately supported by set of Baffles & Tie rods, designed to deliver the specified temperature at outlet by maintaining the element temperature & pressure drop within the safe limits. Heating elements can be fixed to heater flange by means of standoff sleeve pipes with brazing or by direct welding or by means of threaded couplings. Heat duty of a bundle can be divided in to many sub groups (banks) based on process conditions. This will help in better control as flexibility in the operation.
Temperature Sensors: The Heater bundle will have Element skin temperature sensor for monitoring and regulating the Element skin temperature within the limits. The Unit may also need additional sensors such as Tube sheet Temperature Sensor, Terminal Box Sensor, vessel Body temperature sensor and process fluid Temperature sensors based on case to case. The Sensors used for the system will be certified in accordance with the area of installation. The Temperature sensors are Typically RTD or Thermocouple. A simple heater bundle can also be controlled using Thermostat protection for skin & process temperature. If the Operation pressure is High, It is recommended to have a PSV (Pressure safety Valve) installed within the Heater Vessel as an additional safety measure.
Control Panel: Heater controls Panel are designed to monitor & control the operations of the heater bundle also to ensure the safety of the equipment and operations. The control logic can be either ON/OFF (contactor) or regulated (Thyristor) or combination of both in a single panel. The control panels can be installed in both safe area & hazardous area by following respective design guidelines & certification requirements. The Control Panels are provided with various indication systems such as Power ON, Heater ON OFF, Trip, High Temperature etc for comfortable handling of the process. The Temperatures of Elements, Process fluid & other areas (with sensors) are displayed on the Panel for better monitoring & awareness. Control Panel will also have safety interlocks such as high element temperature, Earth fault, process over temperature etc along with Emergency stop access for the safe operation and control.
Advantages

  • Heaters can be used for quick heating of small volume storages as well as for heating large volumes with longer operational hours
  • Widely used for heating high viscous fluids ( Bitumen, HFO etc) and reduce the viscosity before pumping out
  • Environment-friendly design. No hazardous gas/smoke/ emission from the system.
  • Precision Temperature control
  • Can be accommodated in small footprints.
  • Custom designed to meet specifications.
  • Highly energy efficient and provide maximum dielectric strength.
  • Compatible with standard industry piping and safety standards.
  • Reliable design.
  • Easy to operate and maintenance-friendly.
  • Energy Saving.
  • No need to drain the tank for any repair/replacements in case of indirect Immersion Heaters.
  • Heating Elements: Mineral filled insulated Heating Elements or Tubular heating Elements with Ni-Cr (80-20) as heating Coil and suitable outer sheaths.
  • Protections & control: Element Skin Temperature Control, Process Temperature Control, Earth Leakage Protection Overload Current Protection, Temperature Class Protection ( for Hazardous area only)


Application

  • At large Storage Tanks for preheating of thick fluids.
  • Oil Heating (crude, Thermic fluids, and other Process fluids etc in storage tanks).
  • Water heating applications & vaporizer System.
  • For reducing the viscosity of the fluid and make it suitable for pumping out.
  • Steam Boilers.
  • Oil cooling systems & compression packages
  • Edible oil heating for food industries.


Additional Information

  • Payment Terms T/T
  • Port of Dispatch Mumbai
  • Packaging Details Wooden Box Case
  • Delivery Time 6-8 Weeks
Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

Tempsens Instruments (I) Pvt. Ltd. is one of the largest provider for Thermal and Cables Solutions. The headquarters are based in India with production units in Germany and Indonesia. It's a part of Pyrotech group of companies founded in 1976. All companies are ISO 9001, ISO 14001 and OHSAS 18001 certified company with NABL accredited laboratory.
The products offered are Thermocouples, RTDs, Thermowells, Instrumentation and Control cables & wires Signal , Temperature Calibration Equipments, Pyrometers, Industrial heaters, Furnaces and related accessories. Accredited Calibration services are provided for all kind of temperature sensors and furnaces including pyrometers for temperature range -196°C to 2700°C.
Tempsens supply to more than 70 countries; and services customer through dedicated offices or distributors.
  • Nature of Business Manufacturer / Exporter / Service Provider / Supplier / Retailer / Trader
  • Number of Employees 500 - 650
  • Year of Establishment 1976
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Immersion Heater?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice