Listing ID #4669474
Company Information
Ask for more detail from the seller
Contact SupplierKnowing the latest weather conditions is crucial for every boater's plans. The new Acm 52303 Weather Station from WEIBER accurately displays critical weather readings and forecasts for various users.
Â
Knowing the latest weather conditions is crucial for every meteorological application. The new wireless weather station accurately displays critical weather readings and forecasts for boaters, anglers and other outdoor enthusiasts. Utilizing frequency hopping spread spectrum radio technology, it transmits and receives data up to 1,000'. It tracks a large number of weather variables including temperature, barometric pressure, humidity, rainfall, wind speed, wind direction and dew point.
Â
Users can set more than 70 alarms simultaneously for multiple functions. They can graph readings from a 24-hour period, days or months and view more than 80 graphs showing additional temperature, rain, wind and barometric pressure analysis without using a computer. A ticker-tape display indicates forecast details and other data using 100 different messages.
Â
All the weather station's sensors are housed in an integrated sensor suite that easily installs on piers, marina docks and larger boats. The sensor suite is solar powered, and electronic components are protected in a weather-resistant housing.
It has components that can withstand hurricane-force winds and measure wind speeds up to 150 mph with ±5% accuracy. Its temperature sensors are accurate within ±1°F. Vantage Pro weather stations have been recognized by the National Hurricane Center for their exact readings during recent hurricanes and tropical storms.
Console Operating Temperature | +14° to +140°F (-10° to +60°C) |
Display Temperature | +32° to +140°F (0° to +60°C) |
Light Source | LED |
Display | 3 1/2 digits LCD |
Non-operating Temperature | -5° to +158°F (-20° to +70°C) |
Current Draw | 0.90mA average, 20 mA peak, (plus 120 mA for disply lamps, plus 0.125 mA for each optional wireless transmitter received by the console) at 4 to 6 VDC |
Ac Power Adapter | 5VDC, 900mA, regulated |
Batteries | 3 C-cells |
Battery Life | up to 9 months |
Connectors | Modular RJ-11 |
Housing Material | UV-resistant ABS plastic |
Console Display Type | LCD Transflective |
Dimension | - |
Console with antenna | 10.375"x6.125"x1.5" (264mmx156mmx38mm) |
Display | 5.94"x3.375"(151mmx86mm) |
Weight (with batteries) | 1.88IBS.(.85kg) |
Integrated Sensor Suite (ISS) | - |
Operating Temperature | -40° to +150°F (-40° to +65°C) |
Non-operating Temperature | -50° to +158°F (-45° to +70°C) |
Current Draw (ISS SIM only) | 0.14 mA (average), 30mA (peak) at 4 to 6 VDC |
Solar Power Panel (ISS SIM / Fan) | 0.5 watts / .75watts |
Battery (ISS SIM / Fan (Fan-Aspirated) | CR-123 3-Volt Lithium cell / 2- 1.2 Volt NiCad C-cells |
Battery Life (3-Volt Lithium cell) | 8 months without sunlight - greater than 2 years depending on solar charging |
Battery Life (NiCad C-cells) | 1 year |
Fan Aspiration Rate (Fan-Aspirated) | 190 feet/min. (0.9m/s)(full sun), 80 feet/min, (0.4m/s)(battery only) |
Connectors, Sensor | Modular RJ-11 |
Cable Type | 4-conductor, 26 AWG |
Cable Length, anemometer | 40' (12m)(included) 540'(165m) (maximum recommended) |
Wind Speed Sensor | Wind cups with magnetic switch |
Wind Direction Sensor | Wind vane with potentiometer |
Rain Collector Type | Tip bucket, 0.01" per tip (0.2 mm with metric rain adapter), 33.2 in2 (214 cm2) collection area |
Temperature Sensor Type | Thermistor |
Relative Humidity Sensor Type | Film capacitor element |
Housing Material | UV-resistant ABS plastic |
Wind Speed | - |
Resolution and Units | 1 mph, 1km/h, 0.1 m/s, or 1 knot (user-selectable) |
Range (large wind cups) | 2 to 150 mph, 2 to 130 knots, 1 to 67 m/s, 3 to 241 km/h |
Range (small wind cups) | 3 to 175 mph, 3 to 150 knots, 1.5 to 79 m/s, 5 to 282 km/h |
Update Interval | Instant Reading: 2.5 to 3 seconds, 10-minute Average:1 minute |
Accuracy (large wind cups) | ±2 mph (2 kts, 3 km/h, 1m/s) or ±5%, whichever is greater |
Accuracy (small wind cups) | ±3 mph (3 kts, 5 km/h, 1.5m/s) or ±5%, whichever is greater |
Maximum Cable Length | 540' (165 m) |
Current Data | Instant Reading; 10-minute and Hourly Average; Hourly High; Daily, Monthly and Yearly High with Direction of High |
Historical Data | 10-min, and Hourly Averages; Hourly Highs; Daily, Monthly and Yearly Highs with Direction of Highs |
Alarms | High Thresholds from instant Reading and 10-minute Average |
Wind Direction | - |
Display Resolution | 16 points (22.5°) on compas rose, 1° in numeric display |
Accuracy | ±7° |
Update Interval | 2.5 to 3 seconds |
Current Data | Instant Reading (user adjustable); 10-min, Dominant; Hourly, Daily, Monthly Dominant |
Historical Data | Historical Data |
Wind Chill (Calculated) | - |
Resolution and Units | 1oF or 1°C (user-selectable) |
Range | -50° to +158°F (-45° to +70°C) |
Accuracy | ±2oF (±1oC) (typical) |
Update Interval | 10 to 12 seconds |
Souce | United States National Weather Service (NWS)/NOAA |
Equation Used | Osczevski (1995) (adopted by US NWS in 2001) |
Variables Used | Instant Outside Temperature and 10-min. Avg. Wind Speed |
Current Data | Instant Calculation; Hourly, Daily and Monthly Low |
Historical Data | Hourly, Daily and Monthly Lows |
Alarm | Low Threshold from Instant Calculation |
Outsite temperature (sensor located in ISS) | - |
Resolution and Units | Current Date 0 .1°F or 1°F or 0.1°C or 1°C (user-selectable) nominal(see Fig. 1) Historical Data and Alarms: 1°F or 1°C (user-selectable) |
Range | -40° to +150°F (-40° to +65°C) |
Sensor Accuracy | ±1°F (±0.5°C) up to110°F(43°C), ±2°F(±1°C)over 110°F (43°C) See Fig.2) |
Radiation Induced Error (Passive Shield) | +4°F(2°C) at solar noon (insolaton=1040 w/m2,avg.wind speed ≤2mph(1 m/s))(reference:RM young Model 43408 fan-Aspirated Radiation Shield) |
Radiation induced Error(fan-Aspirated) | +0.6°F (0.3°C) at solar noon (insolaton=1040 w/m2,avg.wind speed ≤2mph(1 m/s))(reference:RM young Model 43408 fan-Aspirated Radiation Shield) |
Update interval | 10 to 12 seconds |
Current Data | Instant Reading (user adjustable): Daily, monthly.yearly highs and lows |
Historical Data | hourly Reading Daily monthly.yearly highs and lows |
Alarms | High and low thresholds from instant Reading |
Rainfall | - |
Resolution and Unit | 0.01''or 0.25 mm(user-selectable)(1 mm at totals ≥2000 mm) |
Daily/Storm Rainfall Range | 0to 99.99"(0to 9999mm) |
Monthly/yearly/Total Rainfall Range | 0 to 199.99"(0to 19999mm) |
Rain Rate | 0 to 199.99"(0to 19999mm) |
Accuracy | For rain rates up to 2"/hr (50mm/hr):±4% of total or +0.01"(0.25MM)(0.01"=one tip of the bucket), whichever is greater For rain rates from 2"/hr (50mm/hr)to 4"/hr(100mm/hr): ±5% of total or +0.01"(0.25mm)(0.01"=one tip of the bucket). whicheveris greater |
Update Interval | 10 to 12 seconds |
Storm Determination Method | 0.02"(0.5mm)begins a storm event,24hours without further accumlulation ends a storm event |
Current Data | Totals for past 15-min, past 24 hours,Daily, monthly, yeary (start data user-selectable)and storm(with begin data):Umbrella is displayed when 15 minute Total exceeds zero |
Historical Data | Totals for Past 15-min, Daily, Monthly, Yearly (start date user-selectable) and Storm (with begin and end dates) |
Alarms | High Threshold from Latest Flash Flood (15-min, Total,default is 0.50", 12.7 mm), 24-hour Total, Storm Total, |
Current Data | 0 to 99.99" (0 to 999.7 mm) |
Rain Rate | - |
Resolution and Units | 0.01" or 0.25 mm (user-selectable) at typical rates (see Fig. 3 and 4) |
Range | 0,0.04"/hr (1mm/hr) to 100"/hr (0 to 1999.9 mm/hr) |
Accuracy | ±5% or ±0.04"/hr (1 mm/hr) (up to 10"/hr, (250 mm/hr)), whichever is greater |
Update Interval | 10 to 12 seconds |
Calculation Method | Measures time between successive tips of rain collector.Elapsed time greater than 15 minutes or only one tip of thr rain collector constitutes a rain rate of zero. |
Current Data | Instant and 1-min, Reading; Hourly, Daily, Monthly and Yearly High |
Historical Data | 1-min Reading; Hourly, Daily, Monthly and Yearly Highs |
Alarm | High Threshold from Instant Reading |
Barometric Pressure (sensor located in console) | - |
Resolution and Units | 0.01" Hg, 0.1 mm Hg, 0.1 hPa/mb (user-selectable) |
Corrected Range | 26.00" to 32.00" Hg, 660.0 to 810.0 mm Hg, 880.0 to 1080.0hPa/mb |
Uncorrected Range | 18.00" to 33.50"Hg, 457.0 to 850.0 mm Hg,592.0 to 1130.0 hPa/mb |
Elevation Range | -999' to +12,500' (-305 m to 3810 m) |
Uncorrected Reading Accuracy | ±0.03" Hg (±0.8 mm Hg, ±1.0 hPa/mb) (at room temperature) |
Sea-Level Reduction Equation Used | United States Method employed prior to use of current "R Factor" method |
Equation Source | Smithsonian Meteorological Tables |
Equation Accuracy | ±0.01" Hg (±0.3 mm Hg, ±0.3 hPa/mb) |
Elevation Accuracy Required | ±10' (3m) to meet equation accuracy specification |
Overall Accuracy | ±0.04" Hg (+-1.0 mm Hg, ±1.4 hPa/mb) |
Trend (change in 3 hours) | Change S0.6" (2 hPa/mb, 1.5 mm Hg) = Rapidly Change S0.2" (.7hPa/mb, .5 mm Hg) = Slowly |
Trend Indication | 5 position arrow: Rising (rapidly or slowly), Steady, or Falling (rapidly or slowly) |
Update Interval | 15 minutes or when console BAR key is pressed twice |
Current Data | Instant, 15-min., and Hourly Reading; Daily, Monthly, High and Low |
Historical Data | 15-min. and Hourly Reading; Daily, Monthly Highs and Lows |
Alarms | High Threshold from Current Trend for Storm Clearing (Rising Tredn Low Threshold from Current Trend for Storm Warning (Falling Trend) |
Range for Rising and Falling Trend Alarms | 0.01 to 0.25" Hg (0.1 to 6.4 mm Hg, 0.1 to 8.5 hPa/mb) |
Evapotranspiration (claulated, requires solar radiation sensor) | - |
Resolution and Units | 0.01" or 0.25 mm (user-selectable) |
Range | Daily to 99.99" (999.9 mm); Monthly & Yearly to 199.99" (1999.9 mm) |
Accuracy | Greater of 0.01" (0.25 mm) or ±5%, Reference: side-by-side comparision against a CIMIS ET weather station |
Update Interval | 1hour |
Calculation and Source | Penman-Monteith Equation as implemented by CIMIS (California Irrigation Mangagement Information System) including Net Radiation calculation |
Current Data | Latest Hourly Total Calculation, Daily, Monthly, Yearly Total |
Historical Data | Hourly, Daily, Monthly, Yearly Totals |
Alarm | High Threshold from Latest Daily Total Calculation |
Solar Radiation (requires solar radiation sensor) | - |
Resolution and Units | 1 W/m2 |
Range | 0 to 1800 W/m2 |
Accuracy | ±5% of full scale (Reference: Eppley PSP at 1000 W/m2) |
Drift | up to ±2% per year |
Cosine Reponse | ±3% for angle of incidence from 0° to 75° |
Temperature Coefficient | -0.067% per °F (-0.12% per °C); reference temperature = 77°F (25 °C) |
Update Interval | 50 seconds to 1 minute (5 minutes when dark) |
Current Data | Instant Reading and Hourly Average; Daily, Monthly High |
Historical Data | Hourly Average, Daily, Monthly Highs |
Alarm | High Threshold from Instant Reading |
Ultra Violet (UV) Radiation Index (requires UV sensor) | - |
Resolution and Units | 0.1 Index |
Range | 0 to 16 Index |
Accuracy | +5% of full scale (Reference: Yankee UVB-1 at UV index 10 (Extremely high) |
Cosine Reponse | +4%(0' to 65' incident angle);9% (65' to 85' incident angle) |
Update Interval | 50 seconds to 1 minute (5 minutes when dark) |
Current Data | Instant Reading and Hourly Average: Daily,Monthly high |
Historical Data | hourly Average, Daily, Monthly highs |
Alarm | High Threshold from Instant Calculation |
Ultra Violet (UV)Radiation Dose (requires UV sensor) | - |
Resolution and Units | 0.1MEDs to 19.9 MEDs:1MED above 19.9 MEDS |
Range | 0 to 199 meds |
Accuracy | +5% of daily total |
Drift | up to +2% per year |
Update Interval | 50 seconds to minute (5 minutes when dark) |
Current Data | Latest Daily totals(user resetable at any time from Current Screen) |
Historical Data | Hourly,Daily Totals (user reset from Current Screen does not affect these values) |
Alarms | high Threshold from Daily Total |
Alarm Range | 0 to 19.9 MEDs |
Temperature Measurement Range | 0°C ˜40°C (32 F˜104 F) |
Measurement Temperature Resolution | 1°C(2 F) |
Measurement Range(Brix) | 0%˜85% |
Accuracy | +/- 0.2% |
Automatic Temperature Compensation | 10-40 C |
Power supply | a battery (9V) |
Operation Temperature | 0°C˜40°C(32 F˜104 F) |
Dimension | 185mm ×59mm ×45mm |