Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

WEIBER WEATHER STATION

Listing ID #4669474

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

Knowing the latest weather conditions is crucial for every boater's plans. The new Acm 52303 Weather Station from WEIBER accurately displays critical weather readings and forecasts for various....
View More Details
Send Enquiry

Company Information

  • Member Since 12 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Knowing the latest weather conditions is crucial for every boater's plans. The new Acm 52303 Weather Station from WEIBER accurately displays critical weather readings and forecasts for various users.

 

Knowing the latest weather conditions is crucial for every meteorological application. The new wireless weather station accurately displays critical weather readings and forecasts for boaters, anglers and other outdoor enthusiasts. Utilizing frequency hopping spread spectrum radio technology, it transmits and receives data up to 1,000'. It tracks a large number of weather variables including temperature, barometric pressure, humidity, rainfall, wind speed, wind direction and dew point.

 

Users can set more than 70 alarms simultaneously for multiple functions. They can graph readings from a 24-hour period, days or months and view more than 80 graphs showing additional temperature, rain, wind and barometric pressure analysis without using a computer. A ticker-tape display indicates forecast details and other data using 100 different messages.

 

All the weather station's sensors are housed in an integrated sensor suite that easily installs on piers, marina docks and larger boats. The sensor suite is solar powered, and electronic components are protected in a weather-resistant housing.

It has components that can withstand hurricane-force winds and measure wind speeds up to 150 mph with ±5% accuracy. Its temperature sensors are accurate within ±1°F. Vantage Pro weather stations have been recognized by the National Hurricane Center for their exact readings during recent hurricanes and tropical storms.


Console Operating Temperature +14° to +140°F (-10° to +60°C)
Display Temperature +32° to +140°F (0° to +60°C)
Light Source LED
Display 3 1/2 digits LCD
Non-operating Temperature -5° to +158°F (-20° to +70°C)
Current Draw 0.90mA average, 20 mA peak, (plus 120 mA for disply lamps, plus 0.125 mA for each optional wireless transmitter received by the console) at 4 to 6 VDC
Ac Power Adapter 5VDC, 900mA, regulated
Batteries 3 C-cells
Battery Life up to 9 months
Connectors Modular RJ-11
Housing Material UV-resistant ABS plastic
Console Display Type LCD Transflective
Dimension -
Console with antenna 10.375"x6.125"x1.5" (264mmx156mmx38mm)
Display 5.94"x3.375"(151mmx86mm)
Weight (with batteries) 1.88IBS.(.85kg)
Integrated Sensor Suite (ISS) -
Operating Temperature -40° to +150°F (-40° to +65°C)
Non-operating Temperature -50° to +158°F (-45° to +70°C)
Current Draw (ISS SIM only) 0.14 mA (average), 30mA (peak) at 4 to 6 VDC
Solar Power Panel (ISS SIM / Fan) 0.5 watts / .75watts
Battery (ISS SIM / Fan (Fan-Aspirated) CR-123 3-Volt Lithium cell / 2- 1.2 Volt NiCad C-cells
Battery Life (3-Volt Lithium cell) 8 months without sunlight - greater than 2 years depending on solar charging
Battery Life (NiCad C-cells) 1 year
Fan Aspiration Rate (Fan-Aspirated) 190 feet/min. (0.9m/s)(full sun), 80 feet/min, (0.4m/s)(battery only)
Connectors, Sensor Modular RJ-11
Cable Type 4-conductor, 26 AWG
Cable Length, anemometer 40' (12m)(included) 540'(165m) (maximum recommended)
Wind Speed Sensor Wind cups with magnetic switch
Wind Direction Sensor Wind vane with potentiometer
Rain Collector Type Tip bucket, 0.01" per tip (0.2 mm with metric rain adapter), 33.2 in2 (214 cm2) collection area
Temperature Sensor Type Thermistor
Relative Humidity Sensor Type Film capacitor element
Housing Material UV-resistant ABS plastic
Wind Speed -
Resolution and Units 1 mph, 1km/h, 0.1 m/s, or 1 knot (user-selectable)
Range (large wind cups) 2 to 150 mph, 2 to 130 knots, 1 to 67 m/s, 3 to 241 km/h
Range (small wind cups) 3 to 175 mph, 3 to 150 knots, 1.5 to 79 m/s, 5 to 282 km/h
Update Interval Instant Reading: 2.5 to 3 seconds, 10-minute Average:1 minute
Accuracy (large wind cups) ±2 mph (2 kts, 3 km/h, 1m/s) or ±5%, whichever is greater
Accuracy (small wind cups) ±3 mph (3 kts, 5 km/h, 1.5m/s) or ±5%, whichever is greater
Maximum Cable Length 540' (165 m)
Current Data Instant Reading; 10-minute and Hourly Average; Hourly High; Daily, Monthly and Yearly High with Direction of High
Historical Data 10-min, and Hourly Averages; Hourly Highs; Daily, Monthly and Yearly Highs with Direction of Highs
Alarms High Thresholds from instant Reading and 10-minute Average
Wind Direction -
Display Resolution 16 points (22.5°) on compas rose, 1° in numeric display
Accuracy ±7°
Update Interval 2.5 to 3 seconds
Current Data Instant Reading (user adjustable); 10-min, Dominant; Hourly, Daily, Monthly Dominant
Historical Data Historical Data
Wind Chill (Calculated) -
Resolution and Units 1oF or 1°C (user-selectable)
Range -50° to +158°F (-45° to +70°C)
Accuracy ±2oF (±1oC) (typical)
Update Interval 10 to 12 seconds
Souce United States National Weather Service (NWS)/NOAA
Equation Used Osczevski (1995) (adopted by US NWS in 2001)
Variables Used Instant Outside Temperature and 10-min. Avg. Wind Speed
Current Data Instant Calculation; Hourly, Daily and Monthly Low
Historical Data Hourly, Daily and Monthly Lows
Alarm Low Threshold from Instant Calculation
Outsite temperature (sensor located in ISS) -
Resolution and Units Current Date 0 .1°F or 1°F or 0.1°C or 1°C (user-selectable) nominal(see Fig. 1) Historical Data and Alarms: 1°F or 1°C (user-selectable)
Range -40° to +150°F (-40° to +65°C)
Sensor Accuracy ±1°F (±0.5°C) up to110°F(43°C), ±2°F(±1°C)over 110°F (43°C) See Fig.2)
Radiation Induced Error (Passive Shield) +4°F(2°C) at solar noon (insolaton=1040 w/m2,avg.wind speed ≤2mph(1 m/s))(reference:RM young Model 43408 fan-Aspirated Radiation Shield)
Radiation induced Error(fan-Aspirated) +0.6°F (0.3°C) at solar noon (insolaton=1040 w/m2,avg.wind speed ≤2mph(1 m/s))(reference:RM young Model 43408 fan-Aspirated Radiation Shield)
Update interval 10 to 12 seconds
Current Data Instant Reading (user adjustable): Daily, monthly.yearly highs and lows
Historical Data hourly Reading Daily monthly.yearly highs and lows
Alarms High and low thresholds from instant Reading
Rainfall -
Resolution and Unit 0.01''or 0.25 mm(user-selectable)(1 mm at totals ≥2000 mm)
Daily/Storm Rainfall Range 0to 99.99"(0to 9999mm)
Monthly/yearly/Total Rainfall Range 0 to 199.99"(0to 19999mm)
Rain Rate 0 to 199.99"(0to 19999mm)
Accuracy For rain rates up to 2"/hr (50mm/hr):±4% of total or +0.01"(0.25MM)(0.01"=one tip of the bucket), whichever is greater For rain rates from 2"/hr (50mm/hr)to 4"/hr(100mm/hr): ±5% of total or +0.01"(0.25mm)(0.01"=one tip of the bucket). whicheveris greater
Update Interval 10 to 12 seconds
Storm Determination Method 0.02"(0.5mm)begins a storm event,24hours without further accumlulation ends a storm event
Current Data Totals for past 15-min, past 24 hours,Daily, monthly, yeary (start data user-selectable)and storm(with begin data):Umbrella is displayed when 15 minute Total exceeds zero
Historical Data Totals for Past 15-min, Daily, Monthly, Yearly (start date user-selectable) and Storm (with begin and end dates)
Alarms High Threshold from Latest Flash Flood (15-min, Total,default is 0.50", 12.7 mm), 24-hour Total, Storm Total,
Current Data 0 to 99.99" (0 to 999.7 mm)
Rain Rate -
Resolution and Units 0.01" or 0.25 mm (user-selectable) at typical rates (see Fig. 3 and 4)
Range 0,0.04"/hr (1mm/hr) to 100"/hr (0 to 1999.9 mm/hr)
Accuracy ±5% or ±0.04"/hr (1 mm/hr) (up to 10"/hr, (250 mm/hr)), whichever is greater
Update Interval 10 to 12 seconds
Calculation Method Measures time between successive tips of rain collector.Elapsed time greater than 15 minutes or only one tip of thr rain collector constitutes a rain rate of zero.
Current Data Instant and 1-min, Reading; Hourly, Daily, Monthly and Yearly High
Historical Data 1-min Reading; Hourly, Daily, Monthly and Yearly Highs
Alarm High Threshold from Instant Reading
Barometric Pressure (sensor located in console) -
Resolution and Units 0.01" Hg, 0.1 mm Hg, 0.1 hPa/mb (user-selectable)
Corrected Range 26.00" to 32.00" Hg, 660.0 to 810.0 mm Hg, 880.0 to 1080.0hPa/mb
Uncorrected Range 18.00" to 33.50"Hg, 457.0 to 850.0 mm Hg,592.0 to 1130.0 hPa/mb
Elevation Range -999' to +12,500' (-305 m to 3810 m)
Uncorrected Reading Accuracy ±0.03" Hg (±0.8 mm Hg, ±1.0 hPa/mb) (at room temperature)
Sea-Level Reduction Equation Used United States Method employed prior to use of current "R Factor" method
Equation Source Smithsonian Meteorological Tables
Equation Accuracy ±0.01" Hg (±0.3 mm Hg, ±0.3 hPa/mb)
Elevation Accuracy Required ±10' (3m) to meet equation accuracy specification
Overall Accuracy ±0.04" Hg (+-1.0 mm Hg, ±1.4 hPa/mb)
Trend (change in 3 hours) Change S0.6" (2 hPa/mb, 1.5 mm Hg) = Rapidly
Change S0.2" (.7hPa/mb, .5 mm Hg) = Slowly
Trend Indication 5 position arrow: Rising (rapidly or slowly), Steady, or Falling (rapidly or slowly)
Update Interval 15 minutes or when console BAR key is pressed twice
Current Data Instant, 15-min., and Hourly Reading; Daily, Monthly, High and Low
Historical Data 15-min. and Hourly Reading; Daily, Monthly Highs and Lows
Alarms High Threshold from Current Trend for Storm Clearing (Rising Tredn Low Threshold from Current Trend for Storm Warning (Falling Trend)
Range for Rising and Falling Trend Alarms 0.01 to 0.25" Hg (0.1 to 6.4 mm Hg, 0.1 to 8.5 hPa/mb)
Evapotranspiration (claulated, requires solar radiation sensor) -
Resolution and Units 0.01" or 0.25 mm (user-selectable)
Range Daily to 99.99" (999.9 mm); Monthly & Yearly to 199.99" (1999.9 mm)
Accuracy Greater of 0.01" (0.25 mm) or ±5%, Reference: side-by-side comparision against a CIMIS ET weather station
Update Interval 1hour
Calculation and Source Penman-Monteith Equation as implemented by CIMIS (California Irrigation Mangagement Information System) including Net Radiation calculation
Current Data Latest Hourly Total Calculation, Daily, Monthly, Yearly Total
Historical Data Hourly, Daily, Monthly, Yearly Totals
Alarm High Threshold from Latest Daily Total Calculation
Solar Radiation (requires solar radiation sensor) -
Resolution and Units 1 W/m2
Range 0 to 1800 W/m2
Accuracy ±5% of full scale (Reference: Eppley PSP at 1000 W/m2)
Drift up to ±2% per year
Cosine Reponse ±3% for angle of incidence from 0° to 75°
Temperature Coefficient -0.067% per °F (-0.12% per °C); reference temperature = 77°F (25 °C)
Update Interval 50 seconds to 1 minute (5 minutes when dark)
Current Data Instant Reading and Hourly Average; Daily, Monthly High
Historical Data Hourly Average, Daily, Monthly Highs
Alarm High Threshold from Instant Reading
Ultra Violet (UV) Radiation Index (requires UV sensor) -
Resolution and Units 0.1 Index
Range 0 to 16 Index
Accuracy +5% of full scale (Reference: Yankee UVB-1 at UV index 10 (Extremely high)
Cosine Reponse +4%(0' to 65' incident angle);9% (65' to 85' incident angle)
Update Interval 50 seconds to 1 minute (5 minutes when dark)
Current Data Instant Reading and Hourly Average: Daily,Monthly high
Historical Data hourly Average, Daily, Monthly highs
Alarm High Threshold from Instant Calculation
Ultra Violet (UV)Radiation Dose (requires UV sensor) -
Resolution and Units 0.1MEDs to 19.9 MEDs:1MED above 19.9 MEDS
Range 0 to 199 meds
Accuracy +5% of daily total
Drift up to +2% per year
Update Interval 50 seconds to minute (5 minutes when dark)
Current Data Latest Daily totals(user resetable at any time from Current Screen)
Historical Data Hourly,Daily Totals (user reset from Current Screen does not affect these values)
Alarms high Threshold from Daily Total
Alarm Range 0 to 19.9 MEDs
Temperature Measurement Range 0°C ˜40°C (32 F˜104 F)
Measurement Temperature Resolution 1°C(2 F)
Measurement Range(Brix) 0%˜85%
Accuracy +/- 0.2%
Automatic Temperature Compensation 10-40 C
Power supply a battery (9V)
Operation Temperature 0°C˜40°C(32 F˜104 F)
Dimension 185mm ×59mm ×45mm

Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for WEIBER WEATHER STATION?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
WEIBER WEATHER STATION at Best Price in Delhi - ID: 4669474 | Acmas Technocracy Private Limited
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

WEIBER WEATHER STATION

Listing ID #4669474

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

Knowing the latest weather conditions is crucial for every boater's plans. The new Acm 52303 Weather Station from WEIBER accurately displays critical weather readings and forecasts for various....
View More Details
Send Enquiry

Company Information

  • Member Since 12 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Knowing the latest weather conditions is crucial for every boater's plans. The new Acm 52303 Weather Station from WEIBER accurately displays critical weather readings and forecasts for various users.

 

Knowing the latest weather conditions is crucial for every meteorological application. The new wireless weather station accurately displays critical weather readings and forecasts for boaters, anglers and other outdoor enthusiasts. Utilizing frequency hopping spread spectrum radio technology, it transmits and receives data up to 1,000'. It tracks a large number of weather variables including temperature, barometric pressure, humidity, rainfall, wind speed, wind direction and dew point.

 

Users can set more than 70 alarms simultaneously for multiple functions. They can graph readings from a 24-hour period, days or months and view more than 80 graphs showing additional temperature, rain, wind and barometric pressure analysis without using a computer. A ticker-tape display indicates forecast details and other data using 100 different messages.

 

All the weather station's sensors are housed in an integrated sensor suite that easily installs on piers, marina docks and larger boats. The sensor suite is solar powered, and electronic components are protected in a weather-resistant housing.

It has components that can withstand hurricane-force winds and measure wind speeds up to 150 mph with ±5% accuracy. Its temperature sensors are accurate within ±1°F. Vantage Pro weather stations have been recognized by the National Hurricane Center for their exact readings during recent hurricanes and tropical storms.


Console Operating Temperature +14° to +140°F (-10° to +60°C)
Display Temperature +32° to +140°F (0° to +60°C)
Light Source LED
Display 3 1/2 digits LCD
Non-operating Temperature -5° to +158°F (-20° to +70°C)
Current Draw 0.90mA average, 20 mA peak, (plus 120 mA for disply lamps, plus 0.125 mA for each optional wireless transmitter received by the console) at 4 to 6 VDC
Ac Power Adapter 5VDC, 900mA, regulated
Batteries 3 C-cells
Battery Life up to 9 months
Connectors Modular RJ-11
Housing Material UV-resistant ABS plastic
Console Display Type LCD Transflective
Dimension -
Console with antenna 10.375"x6.125"x1.5" (264mmx156mmx38mm)
Display 5.94"x3.375"(151mmx86mm)
Weight (with batteries) 1.88IBS.(.85kg)
Integrated Sensor Suite (ISS) -
Operating Temperature -40° to +150°F (-40° to +65°C)
Non-operating Temperature -50° to +158°F (-45° to +70°C)
Current Draw (ISS SIM only) 0.14 mA (average), 30mA (peak) at 4 to 6 VDC
Solar Power Panel (ISS SIM / Fan) 0.5 watts / .75watts
Battery (ISS SIM / Fan (Fan-Aspirated) CR-123 3-Volt Lithium cell / 2- 1.2 Volt NiCad C-cells
Battery Life (3-Volt Lithium cell) 8 months without sunlight - greater than 2 years depending on solar charging
Battery Life (NiCad C-cells) 1 year
Fan Aspiration Rate (Fan-Aspirated) 190 feet/min. (0.9m/s)(full sun), 80 feet/min, (0.4m/s)(battery only)
Connectors, Sensor Modular RJ-11
Cable Type 4-conductor, 26 AWG
Cable Length, anemometer 40' (12m)(included) 540'(165m) (maximum recommended)
Wind Speed Sensor Wind cups with magnetic switch
Wind Direction Sensor Wind vane with potentiometer
Rain Collector Type Tip bucket, 0.01" per tip (0.2 mm with metric rain adapter), 33.2 in2 (214 cm2) collection area
Temperature Sensor Type Thermistor
Relative Humidity Sensor Type Film capacitor element
Housing Material UV-resistant ABS plastic
Wind Speed -
Resolution and Units 1 mph, 1km/h, 0.1 m/s, or 1 knot (user-selectable)
Range (large wind cups) 2 to 150 mph, 2 to 130 knots, 1 to 67 m/s, 3 to 241 km/h
Range (small wind cups) 3 to 175 mph, 3 to 150 knots, 1.5 to 79 m/s, 5 to 282 km/h
Update Interval Instant Reading: 2.5 to 3 seconds, 10-minute Average:1 minute
Accuracy (large wind cups) ±2 mph (2 kts, 3 km/h, 1m/s) or ±5%, whichever is greater
Accuracy (small wind cups) ±3 mph (3 kts, 5 km/h, 1.5m/s) or ±5%, whichever is greater
Maximum Cable Length 540' (165 m)
Current Data Instant Reading; 10-minute and Hourly Average; Hourly High; Daily, Monthly and Yearly High with Direction of High
Historical Data 10-min, and Hourly Averages; Hourly Highs; Daily, Monthly and Yearly Highs with Direction of Highs
Alarms High Thresholds from instant Reading and 10-minute Average
Wind Direction -
Display Resolution 16 points (22.5°) on compas rose, 1° in numeric display
Accuracy ±7°
Update Interval 2.5 to 3 seconds
Current Data Instant Reading (user adjustable); 10-min, Dominant; Hourly, Daily, Monthly Dominant
Historical Data Historical Data
Wind Chill (Calculated) -
Resolution and Units 1oF or 1°C (user-selectable)
Range -50° to +158°F (-45° to +70°C)
Accuracy ±2oF (±1oC) (typical)
Update Interval 10 to 12 seconds
Souce United States National Weather Service (NWS)/NOAA
Equation Used Osczevski (1995) (adopted by US NWS in 2001)
Variables Used Instant Outside Temperature and 10-min. Avg. Wind Speed
Current Data Instant Calculation; Hourly, Daily and Monthly Low
Historical Data Hourly, Daily and Monthly Lows
Alarm Low Threshold from Instant Calculation
Outsite temperature (sensor located in ISS) -
Resolution and Units Current Date 0 .1°F or 1°F or 0.1°C or 1°C (user-selectable) nominal(see Fig. 1) Historical Data and Alarms: 1°F or 1°C (user-selectable)
Range -40° to +150°F (-40° to +65°C)
Sensor Accuracy ±1°F (±0.5°C) up to110°F(43°C), ±2°F(±1°C)over 110°F (43°C) See Fig.2)
Radiation Induced Error (Passive Shield) +4°F(2°C) at solar noon (insolaton=1040 w/m2,avg.wind speed ≤2mph(1 m/s))(reference:RM young Model 43408 fan-Aspirated Radiation Shield)
Radiation induced Error(fan-Aspirated) +0.6°F (0.3°C) at solar noon (insolaton=1040 w/m2,avg.wind speed ≤2mph(1 m/s))(reference:RM young Model 43408 fan-Aspirated Radiation Shield)
Update interval 10 to 12 seconds
Current Data Instant Reading (user adjustable): Daily, monthly.yearly highs and lows
Historical Data hourly Reading Daily monthly.yearly highs and lows
Alarms High and low thresholds from instant Reading
Rainfall -
Resolution and Unit 0.01''or 0.25 mm(user-selectable)(1 mm at totals ≥2000 mm)
Daily/Storm Rainfall Range 0to 99.99"(0to 9999mm)
Monthly/yearly/Total Rainfall Range 0 to 199.99"(0to 19999mm)
Rain Rate 0 to 199.99"(0to 19999mm)
Accuracy For rain rates up to 2"/hr (50mm/hr):±4% of total or +0.01"(0.25MM)(0.01"=one tip of the bucket), whichever is greater For rain rates from 2"/hr (50mm/hr)to 4"/hr(100mm/hr): ±5% of total or +0.01"(0.25mm)(0.01"=one tip of the bucket). whicheveris greater
Update Interval 10 to 12 seconds
Storm Determination Method 0.02"(0.5mm)begins a storm event,24hours without further accumlulation ends a storm event
Current Data Totals for past 15-min, past 24 hours,Daily, monthly, yeary (start data user-selectable)and storm(with begin data):Umbrella is displayed when 15 minute Total exceeds zero
Historical Data Totals for Past 15-min, Daily, Monthly, Yearly (start date user-selectable) and Storm (with begin and end dates)
Alarms High Threshold from Latest Flash Flood (15-min, Total,default is 0.50", 12.7 mm), 24-hour Total, Storm Total,
Current Data 0 to 99.99" (0 to 999.7 mm)
Rain Rate -
Resolution and Units 0.01" or 0.25 mm (user-selectable) at typical rates (see Fig. 3 and 4)
Range 0,0.04"/hr (1mm/hr) to 100"/hr (0 to 1999.9 mm/hr)
Accuracy ±5% or ±0.04"/hr (1 mm/hr) (up to 10"/hr, (250 mm/hr)), whichever is greater
Update Interval 10 to 12 seconds
Calculation Method Measures time between successive tips of rain collector.Elapsed time greater than 15 minutes or only one tip of thr rain collector constitutes a rain rate of zero.
Current Data Instant and 1-min, Reading; Hourly, Daily, Monthly and Yearly High
Historical Data 1-min Reading; Hourly, Daily, Monthly and Yearly Highs
Alarm High Threshold from Instant Reading
Barometric Pressure (sensor located in console) -
Resolution and Units 0.01" Hg, 0.1 mm Hg, 0.1 hPa/mb (user-selectable)
Corrected Range 26.00" to 32.00" Hg, 660.0 to 810.0 mm Hg, 880.0 to 1080.0hPa/mb
Uncorrected Range 18.00" to 33.50"Hg, 457.0 to 850.0 mm Hg,592.0 to 1130.0 hPa/mb
Elevation Range -999' to +12,500' (-305 m to 3810 m)
Uncorrected Reading Accuracy ±0.03" Hg (±0.8 mm Hg, ±1.0 hPa/mb) (at room temperature)
Sea-Level Reduction Equation Used United States Method employed prior to use of current "R Factor" method
Equation Source Smithsonian Meteorological Tables
Equation Accuracy ±0.01" Hg (±0.3 mm Hg, ±0.3 hPa/mb)
Elevation Accuracy Required ±10' (3m) to meet equation accuracy specification
Overall Accuracy ±0.04" Hg (+-1.0 mm Hg, ±1.4 hPa/mb)
Trend (change in 3 hours) Change S0.6" (2 hPa/mb, 1.5 mm Hg) = Rapidly
Change S0.2" (.7hPa/mb, .5 mm Hg) = Slowly
Trend Indication 5 position arrow: Rising (rapidly or slowly), Steady, or Falling (rapidly or slowly)
Update Interval 15 minutes or when console BAR key is pressed twice
Current Data Instant, 15-min., and Hourly Reading; Daily, Monthly, High and Low
Historical Data 15-min. and Hourly Reading; Daily, Monthly Highs and Lows
Alarms High Threshold from Current Trend for Storm Clearing (Rising Tredn Low Threshold from Current Trend for Storm Warning (Falling Trend)
Range for Rising and Falling Trend Alarms 0.01 to 0.25" Hg (0.1 to 6.4 mm Hg, 0.1 to 8.5 hPa/mb)
Evapotranspiration (claulated, requires solar radiation sensor) -
Resolution and Units 0.01" or 0.25 mm (user-selectable)
Range Daily to 99.99" (999.9 mm); Monthly & Yearly to 199.99" (1999.9 mm)
Accuracy Greater of 0.01" (0.25 mm) or ±5%, Reference: side-by-side comparision against a CIMIS ET weather station
Update Interval 1hour
Calculation and Source Penman-Monteith Equation as implemented by CIMIS (California Irrigation Mangagement Information System) including Net Radiation calculation
Current Data Latest Hourly Total Calculation, Daily, Monthly, Yearly Total
Historical Data Hourly, Daily, Monthly, Yearly Totals
Alarm High Threshold from Latest Daily Total Calculation
Solar Radiation (requires solar radiation sensor) -
Resolution and Units 1 W/m2
Range 0 to 1800 W/m2
Accuracy ±5% of full scale (Reference: Eppley PSP at 1000 W/m2)
Drift up to ±2% per year
Cosine Reponse ±3% for angle of incidence from 0° to 75°
Temperature Coefficient -0.067% per °F (-0.12% per °C); reference temperature = 77°F (25 °C)
Update Interval 50 seconds to 1 minute (5 minutes when dark)
Current Data Instant Reading and Hourly Average; Daily, Monthly High
Historical Data Hourly Average, Daily, Monthly Highs
Alarm High Threshold from Instant Reading
Ultra Violet (UV) Radiation Index (requires UV sensor) -
Resolution and Units 0.1 Index
Range 0 to 16 Index
Accuracy +5% of full scale (Reference: Yankee UVB-1 at UV index 10 (Extremely high)
Cosine Reponse +4%(0' to 65' incident angle);9% (65' to 85' incident angle)
Update Interval 50 seconds to 1 minute (5 minutes when dark)
Current Data Instant Reading and Hourly Average: Daily,Monthly high
Historical Data hourly Average, Daily, Monthly highs
Alarm High Threshold from Instant Calculation
Ultra Violet (UV)Radiation Dose (requires UV sensor) -
Resolution and Units 0.1MEDs to 19.9 MEDs:1MED above 19.9 MEDS
Range 0 to 199 meds
Accuracy +5% of daily total
Drift up to +2% per year
Update Interval 50 seconds to minute (5 minutes when dark)
Current Data Latest Daily totals(user resetable at any time from Current Screen)
Historical Data Hourly,Daily Totals (user reset from Current Screen does not affect these values)
Alarms high Threshold from Daily Total
Alarm Range 0 to 19.9 MEDs
Temperature Measurement Range 0°C ˜40°C (32 F˜104 F)
Measurement Temperature Resolution 1°C(2 F)
Measurement Range(Brix) 0%˜85%
Accuracy +/- 0.2%
Automatic Temperature Compensation 10-40 C
Power supply a battery (9V)
Operation Temperature 0°C˜40°C(32 F˜104 F)
Dimension 185mm ×59mm ×45mm

Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for WEIBER WEATHER STATION?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice