Company Information
Ask for more detail from the seller
Contact SupplierFeatures | |
All features of Prizm Touch Screen Operator Interfaces | |
Integrated Digital Inputs and Outputs with optional Analog I/O | |
Digital Inputs and Outputs rated for 24 V DC | |
Analog Inputs for RTD, mV and mA. Analog Outputs are 4-20 mA / 0-10 VDC | |
Inputs connectable to PLC or used for internal program | |
Support for Ladder Logic and Analog control | |
High Speed Counters and Timers | |
Two Communication Ports: Universal serial ports to connect PLC / Printer / Programming Port | |
Data Logging, Trending (Real Time & Historical), Alarms (Real Time & Historical) | |
Built-in PID, PWM functionality | |
Multilanguage (Unicode) support with true type Windows® fonts | |
IP65 design. CE and UL certified
|
Basic HIO Operations | ||
The HIO units possess both Prizm (Operator interface) as well as programmable logic features. The user can implement logic, specific to application using standard Ladder programming. The HIO unit has four 32-bit High Speed Counters (Normal and Quadrature Mode), Rate measurement capability (max. up to 25kHz), Timers and Counters, Internal Coils, retentive and non-retentive memory and PID functionality. A PLC logic task can be programmed for continuous scanning, or only when a specific screen is showing. The HIO operator interface functions revolve around Screens and Tasks that can be assigned to screens and application. The HIO can also display an Alarm conditions. | ||
Supported Tasks are listed below:
| ||
Digital I/O HIO Touch Screens can have up to 28 digital inputs and 16 digital outputs on the unit. Digital inputs are high impedance 24 VDC and outputs are relay (NO), transistor outputs or a combination of both. The Digital I/O capability of HIO units can be expanded using external add on I/O Modules. Analog I/O The HIO controllers can have up to 4 universal analog inputs and 2 analog outputs. Analog inputs are mA, mV and RTD. The Analog outputs are 4-20 mA or 0-10 VDC. Analog I/O capability of HIO units can be expanded using external add on I/O Modules. PID The built-in PID controller can process 12 independent inputs in addition to the Analog inputs of the unit. The input to the PID controller is a data register, which can hold an analog input or any other value. High Speed Counters PWM Touch Keys Task Multilanguage / Unicode Support Communication Ports: | ||
System requirements for Prizm Setup Software are: | ||
Windows Version : Microsoft Windows® 2000 or above Processor : 266 MHz PENTIUM or higher Mouse : Required RAM : 64 MB or more Display resolution : 800 x 600 (VGA) or better Display colors : 256 colors or more Serial Port : 1 serial port for HIO programming Keyboard : Required |
Analog Outputs: Current / Voltage | 4-20 mA , 0-10V |
Digital Inputs: Rated Input Voltage - | |
Digital Outputs (Open Collector): Maximum Load current Voltage drop at ON | 300 mA (for NPN) and 500 mA (for PNP) 0.4V or less |
Digital Outputs (Relay): Relay Rating | 230V AC, 2 Amp. (max) |