Contact SupplierThe Industrial Water Heater (Air Source Heating / Heat Pump) provided by us first absorbs atmospheric heat and then concentrates it to further releasing to water. The Industrial Water Heater that we bring forth is not only long lasting but also renders excellent performance that makes it even more demanding in the market. Also, we are one of the well-established Manufacturers and Suppliers of Industrial Water Heater in the domain.
Specifications
Water Heating Unit Model | TCH | 1000 | 2000 | 5000 | 10000 |
Parameter | Unit | Value | Value | Value | Value |
Water Heating Capacity | L/HR | 100 | 200 | 500 | 1000 |
Power in put | Kw/Hr | 1.25 | 2.5 | 6.25 | 12.5 |
No. of units | No | 1 | 1 | 1 | 1 |
Water inlet temp. (Approx) | oC | 20-30 | 20-30 | 20-30 | 20-30 |
Water outlet temp(Approx) | oC | 50-60 | 50-60 | 50-60 | 50-60 |
Water volume to be heated | Litres | 1000 | 2000 | 5000 | 10000 |
Heating time for above mentioned volume | Hrs. | 10 hrs. | 10 hrs. | 10 hrs. | 10 hrs. |
Total Energy Consumption(With20% wastage) | Rs/Hr | 10.5 | 21 | 52.5 | 105 |
Power tariff (assumed) | Rs. | 7 | 7 | 7 | 7 |
Operating cost for Heating above mentioned volume. | Rs | 105 | 210 | 525 | 1050 |
Max .Out put Hot water Temp. | oC | 60 | 60 | 60 | 60 |
Operating temp range(Ambient) | oC | 10̢۪~50 | 10̢۪~50 | 10̢۪~50 | 10̢۪~50 |
Material | - | Stainless steel | S.S. | S.S. | S.S. |
Therm `O̢۪ chill foot print | Sqmt | 0.25 | 0.35 | 0.5 | 1 |
Volume of swimming pool water which could be heated up to 35̢۪c | Liters | 10000 | 20000 | 50000 | 1,00,000 |
Water To Be Heated | 1000 Liters |
Water inlet Temperature | 30 oC |
Water Outlet Temperature | 50 oC to 60 oC |
Parameter | Unit | Diesel Boiler | Electric Geyser | Solar Heater | Therm̢۪O̢۪ChillTMTCH-1000 |
Energy Consuption /day | Lts (or)Kwh | 10Ltrs of Diesel | 48 Kwhr | 48 Kwhr | 15 Kwhr |
Power / Fuel Rate | Rs. | Rs.45.00 | Rs.7.00 | Rs.7.00 | Rs.7.00 |
Operating Cost / day | Rs. | Rs.450 | Rs.336 | Rs.336 | Rs.105 |
No. of days used in a year | Days | 365 | 365 | *115 | 365 |
Operating Cost / Year(Heating) | Rs. | Rs.164250 | Rs.121545 | Rs.38640 | Rs.38325 |
Solar Water Heater | Therm 'O' ChillTMTCH-1000/2000/5000/10000 |
High Initial Investment | Lower Initial Investment |
Not reliable in monsoons, when hot water is needed the most; forcing you to use electric heater / diesel boilers, increasing your operating cost. | 100% reliable, works in all weather conditions, with the lowest energy consumption. |
Does not work at night, if hot water is used up, there will be no hot water available for the morning. | Works 365 days and nights a year. |
Must be installed on roof top | Does not need sun light; can be installed anywhere; including the cellar. |
Takes up a lot of space; wasting lot of usable and valuable terrace space. | Very compact, no paneling. Takes up a fraction of the space. |
Is not efficient in cold/cloudy places, shadowed buildings. | Ideal solution; does not depend on sunlight. |
Relocation is difficult | Very easy to relocate |
Spoils the look of your home / Hotel / Resort. | Not visible from the outside of the building. |
Water Heating Unit Model | TCH | 1000 | 2000 | 5000 | 10000 |
---|---|---|---|---|---|
Parameter | Unit | Value | Value | Value | Value |
Water Heating Capacity | L/HR | 100 | 200 | 500 | 1000 |
Power in put | Kw/Hr | 1.25 | 2.5 | 6.25 | 12.5 |
No. of units | No | 1 | 1 | 1 | 1 |
Water inlet temp. (Approx) | oC | 20-30 | 20-30 | 20-30 | 20-30 |
Water outlet temp(Approx) | oC | 50-60 | 50-60 | 50-60 | 50-60 |
Water volume to be heated | Litres | 1000 | 2000 | 5000 | 10000 |
Heating time for above mentioned volume | Hrs. | 10 hrs. | 10 hrs. | 10 hrs. | 10 hrs. |
Total Energy Consumption(With20% wastage) | Rs/Hr | 10.5 | 21 | 52.5 | 105 |
Power tariff (assumed) | Rs. | 7 | 7 | 7 | 7 |
Operating cost for Heating above mentioned volume. | Rs | 105 | 210 | 525 | 1050 |
Max .Out put Hot water Temp. | oC | 60 | 60 | 60 | 60 |
Operating temp range(Ambient) | oC | 10’~50 | 10’~50 | 10’~50 | 10’~50 |
Material | - | Stainless steel | S.S. | S.S. | S.S. |
Therm `O’ chill foot print | Sqmt | 0.25 | 0.35 | 0.5 | 1 |
Volume of swimming pool water which could be heated up to 35’c | Liters | 10000 | 20000 | 50000 | 1,00,000 |
Water Heating Unit Model | TCH | 1000 | 2000 | 5000 | 10000 |
---|---|---|---|---|---|
Parameter | Unit | Value | Value | Value | Value |
Water Heating Capacity | L/HR | 100 | 200 | 500 | 1000 |
Power in put | Kw/Hr | 1.25 | 2.5 | 6.25 | 12.5 |
No. of units | No | 1 | 1 | 1 | 1 |
Water inlet temp. (Approx) | oC | 20-30 | 20-30 | 20-30 | 20-30 |
Water outlet temp(Approx) | oC | 50-60 | 50-60 | 50-60 | 50-60 |
Water volume to be heated | Litres | 1000 | 2000 | 5000 | 10000 |
Heating time for above mentioned volume | Hrs. | 10 hrs. | 10 hrs. | 10 hrs. | 10 hrs. |
Total Energy Consumption(With20% wastage) | Rs/Hr | 10.5 | 21 | 52.5 | 105 |
Power tariff (assumed) | Rs. | 7 | 7 | 7 | 7 |
Operating cost for Heating above mentioned volume. | Rs | 105 | 210 | 525 | 1050 |
Max .Out put Hot water Temp. | oC | 60 | 60 | 60 | 60 |
Operating temp range(Ambient) | oC | 10’~50 | 10’~50 | 10’~50 | 10’~50 |
Material | - | Stainless steel | S.S. | S.S. | S.S. |
Therm `O’ chill foot print | Sqmt | 0.25 | 0.35 | 0.5 | 1 |
Volume of swimming pool water which could be heated up to 35’c | Liters | 10000 | 20000 | 50000 | 1,00,00 |
Water To Be Heated | 1000 Liters |
---|---|
Water inlet Temperature | 30 oC |
Water Outlet Temperature | 50 oC to 60 oC |
Water To Be Heated | 1000 Liters |
---|---|
Water inlet Temperature | 30 oC |
Water Outlet Temperature | 50 oC to 60 oC |
Parameter | Unit | Diesel Boiler | Electric Geyser | Solar Heater | Therm’O’ChillTMTCH-1000 | |
---|---|---|---|---|---|---|
Energy Consuption /day | Lts (or)Kwh | 10Ltrs of Diesel | 48 Kwhr | 48 Kwhr | 15 Kwhr | |
Power / Fuel Rate | Rs. | Rs.45.00 | Rs.7.00 | Rs.7.00 | Rs.7.00 | |
Operating Cost / day | Rs. | Rs.450 | Rs.336 | Rs.336 | Rs.105 | |
No. of days used in a year | Days | 365 | 365 | *115 | 365 | |
Operating Cost / Year(Heating) | Rs. | Rs.164250 | Rs.121545 | Rs.38640 | Rs.38325 | |
Why Therm‘O’ ChillTM TCD-1000/2000/5000/10000 |
Solar Water Heater | Therm 'O' ChillTMTCH-1000/2000/5000/10000 |
---|---|
High Initial Investment | Lower Initial Investment |
Not reliable in monsoons, when hot water is needed the most; forcing you to use electric heater / diesel boilers, increasing your operating cost. | 100% reliable, works in all weather conditions, with the lowest energy consumption. |
Does not work at night, if hot water is used up, there will be no hot water available for the morning. | Works 365 days and nights a year. |
Must be installed on roof top | Does not need sun light; can be installed anywhere; including the cellar. |
Takes up a lot of space; wasting lot of usable and valuable terrace space. | Very compact, no paneling. Takes up a fraction of the space. |
Is not efficient in cold/cloudy places, shadowed buildings. | Ideal solution; does not depend on sunlight. |
Relocation is difficult | Very easy to relocate |
Spoils the look of your home / Hotel / Resort. | Not visible from the outside of the building. |
Note : Solar works for only 250 days a year, electric backup/diesel boiler, etc. must be used for remaining no of days. |
Parameter | Unit | Diesel Boiler | Electric Geyser | Solar Heater | Therm’O’ChillTMTCH-1000 |
---|---|---|---|---|---|
Energy Consuption /day | Lts (or)Kwh | 10Ltrs of Diesel | 48 Kwhr | 48 Kwhr | 15 Kwhr |
Power / Fuel Rate | Rs. | Rs.45.00 | Rs.7.00 | Rs.7.00 | Rs.7.00 |
Operating Cost / day | Rs. | Rs.450 | Rs.336 | Rs.336 | Rs.105 |
No. of days used in a year | Days | 365 | 365 | *115 | 365 |
Operating Cost / Year(Heating) | Rs. | Rs.164250 | Rs.121545 | Rs.38640 | Rs.38325 |
Why Therm‘O’ ChillTM TCD-1000/2000/5000/10000 |
Solar Water Heater | Therm 'O' ChillTMTCH-1000/2000/5000/10000 |
---|---|
High Initial Investment | Lower Initial Investment |
Not reliable in monsoons, when hot water is needed the most; forcing you to use electric heater / diesel boilers, increasing your operating cost. | 100% reliable, works in all weather conditions, with the lowest energy consumption. |
Does not work at night, if hot water is used up, there will be no hot water available for the morning. | Works 365 days and nights a year. |
Must be installed on roof top | Does not need sun light; can be installed anywhere; including the cellar. |
Takes up a lot of space; wasting lot of usable and valuable terrace space. | Very compact, no paneling. Takes up a fraction of the space. |
Is not efficient in cold/cloudy places, shadowed buildings. | Ideal solution; does not depend on sunlight. |
Relocation is difficult | Very easy to relocate |
Spoils the look of your home / Hotel / Resort. | Not visible from the outside of the building. |
Note : Solar works for only 250 days a year, electric backup/diesel boiler, etc. must be used for remaining no of days. |
Water Heating Unit Model | TCH | 1000 | 2000 | 5000 | 10000 |
---|---|---|---|---|---|
Parameter | Unit | Value | Value | Value | Value |
Water Heating Capacity | L/HR | 100 | 200 | 500 | 1000 |
Power in put | Kw/Hr | 1.25 | 2.5 | 6.25 | 12.5 |
No. of units | No | 1 | 1 | 1 | 1 |
Water inlet temp. (Approx) | oC | 20-30 | 20-30 | 20-30 | 20-30 |
Water outlet temp(Approx) | oC | 50-60 | 50-60 | 50-60 | 50-60 |
Water volume to be heated | Litres | 1000 | 2000 | 5000 | 10000 |
Heating time for above mentioned volume | Hrs. | 10 hrs. | 10 hrs. | 10 hrs. | 10 hrs. |
Total Energy Consumption(With20% wastage) | Rs/Hr | 10.5 | 21 | 52.5 | 105 |
Power tariff (assumed) | Rs. | 7 | 7 | 7 | 7 |
Operating cost for Heating above mentioned volume. | Rs | 105 | 210 | 525 | 1050 |
Max .Out put Hot water Temp. | oC | 60 | 60 | 60 | 60 |
Operating temp range(Ambient) | oC | 10’~50 | 10’~50 | 10’~50 | 10’~50 |
Material | - | Stainless steel | S.S. | S.S. | S.S. |
Therm `O’ chill foot print | Sqmt | 0.25 | 0.35 | 0.5 | 1 |
Volume of swimming pool water which could be heated up to 35’c | Liters | 10000 | 20000 | 50000 | 1,00,000 |
Water To Be Heated | 1000 Liters |
---|---|
Water inlet Temperature | 30 oC |
Water Outlet Temperature | 50 oC to 60 oC |
Boilers | Therm O ChillTMTCH-1000/2000/5000/10000 |
---|---|
Rising fuel prices, meaning high and increasing running cost. | Runs on very little electricity, hence lower and stable running cost. |
Requires separate infrastructure/ storage room etc. | No special infrastructure, no separate storage space. |
Risk of shortage/ untimely fuel supply. | Electricity is readily and universally available. |
Faces probable ban by the government | No such risk, is eco-friendly and does not pollute the environment. |
Staff required for manual operation. | Fully automatic operation. |
Electric Geyser | Therm O ChillTMTCH-1000/2000/5000/10000 |
---|---|
Extremely high operating cost | Saves you up to 75% electricity |
Not reliable during power cuts | Stores required amount of hot water in an insulated tank, hence more reliable during power cuts. |
Only 75% efficient | 300% more efficient than conventional heating methods. |
To enquire about the desired product(s), just check the box and then click “Inquiry Now” button which is provided below. |
Parameter
Unit | Diesel Boiler | Electric Geyser | Solar Heater | Therm’O’ChillTMTCH-1000 | |
---|---|---|---|---|---|
Energy Consuption /day | Lts (or)Kwh | 10Ltrs of Diesel | 48 Kwhr | 48 Kwhr | 15 Kwhr |
Power / Fuel Rate | Rs. | Rs.45.00 | Rs.7.00 | Rs.7.00 | Rs.7.00 |
Operating Cost / day | Rs. | Rs.450 | Rs.336 | Rs.336 | Rs.105 |
No. of days used in a year | Days | 365 | 365 | *115 | 365 |
Operating Cost / Year(Heating) | Rs. | Rs.164250 | Rs.121545 | Rs.38640 | Rs.38325 |
Why Therm‘O’ ChillTM TCD-1000/2000/5000/10000 |
Solar Water Heater | Therm 'O' ChillTMTCH-1000/2000/5000/10000 |
---|---|
High Initial Investment | Lower Initial Investment |
Not reliable in monsoons, when hot water is needed the most; forcing you to use electric heater / diesel boilers, increasing your operating cost. | 100% reliable, works in all weather conditions, with the lowest energy consumption. |
Does not work at night, if hot water is used up, there will be no hot water available for the morning. | Works 365 days and nights a year. |
Must be installed on roof top | Does not need sun light; can be installed anywhere; including the cellar. |
Takes up a lot of space; wasting lot of usable and valuable terrace space. | Very compact, no paneling. Takes up a fraction of the space. |
Is not efficient in cold/cloudy places, shadowed buildings. | Ideal solution; does not depend on sunlight. |
Relocation is difficult | Very easy to relocate |
Spoils the look of your home / Hotel / Resort. | Not visible from the outside of the building. |
Note : Solar works for only 250 days a year, electric backup/diesel boiler, etc. must be used for remaining no of days. |
Boilers | Therm O ChillTMTCH-1000/2000/5000/10000 |
---|---|
Rising fuel prices, meaning high and increasing running cost. | Runs on very little electricity, hence lower and stable running cost. |
Requires separate infrastructure/ storage room etc. | No special infrastructure, no separate storage space. |
Risk of shortage/ untimely fuel supply. | Electricity is readily and universally available. |
Faces probable ban by the government | No such risk, is eco-friendly and does not pollute the environment. |
Staff required for manual operation. | Fully automatic operation. |
Electric Geyser | Therm O ChillTMTCH-1000/2000/5000/10000 |
---|---|
Extremely high operating cost | Saves you up to 75% electricity |
Not reliable during power cuts | Stores required amount of hot water in an insulated tank, hence more reliable during power cuts. |
Only 75% efficient | 300% more efficient than conventional heating methods. |
To enquire about the desired product(s), just check the box and then click “Inquiry Now” button which is provided below. |