Company Information
Ask for more detail from the seller
Contact SupplierThe Thermic Fluid Heater that we offer our clients is sourced from trusted vendors. Our fuel fired thermic fluid heater is easy and safe to handle, as it is incorporated with various safety measure equipment. They need low maintenance and provide long lasting brilliant performance even in tough weather conditions.
Details | Unit | NT-50 | NT-100 | NT-200 | NT-300 | NT-400 | NT-600 | NT-1000 |
Operating Parameters Capacity | KCals/Hr. | 50000 | 100000 | 200000 | 300000 | 400000 | 600000 | 1000000 |
Max. Operating Temp. (At the outlet of the unit) | 0C | 300 | 300 | 300 | 300 | 300 | 300 | 300 |
Fuel Oil Consumption At full load LDO FO | Kgs/Hr Kgs/Hr. | 5.4 | 10.8 | 21.5 22.6 | 32.4 33.9 | 42.9 45 | 64.3 67.5 | 107.2 112.5 |
Efficiency (GCV) | % | 86+/-1 | 86+/-1 | 86+/-1 | 86+/-1 | 86+/-1 | 86+/-1 | 86+/-1 |
Burner Contro | -------------------------ON-OFF------------------ | |||||||
Electric Supply | AC-3 Phase - 415V +/- 6% 50 Hz 4 Wire | |||||||
Thermic Fluid Pump Motor | (HP) | 3 | 5 | 7.5 | 10 | 10 | 20 | 25 |
Blower Motor | (HP) | 1 | 1.5 | 2 | 2 | 3 | 5 | 10 |
Fuel Oil Preheater (For F.O. Fired Unit Only) | KW | - | - | 3 | 4.5 | 4.5 | 6 | 9 |
Total Elec. Load For LDO Fired Units For FO Fired Units | HP HP + KW | 4 | 6.5 | 9.5 9.5+3 | 12 12+4.5 | 13 13+4.5 | 25 25+6 | 35 35+9 |
Length | (Mts) | 2 | 3 | 4 | 4 | 4 | 4 | 4 |
Width | (Mts) | 2 | 3 | 4 | 4 | 4 | 5 | 5 |
Clear Height | (Mts) | 2.5 | 2.5 | 4 | 5 | 5 | 5 | 6 |
Fuel Gas Outlet | (MM) | 250 | 250 | 250 | 300 | 30 | 400 | 500 |
Cross Dry Weight | (Kgs) | 1000 | 1350 | 1750 | 2400 | 2900 | 3500 | 5250 |
PARAMETERS | UNIT | NTC : 200 | NTC : 300 | NTC : 400 | NTC : 600 | NTC : 1000 | - | - |
Heat Output | Kcal/hr | 2,00,000 | 3,00,000 | 4,00,000 | 6,00,000 | 10,00,000 | - | - |
Outlet temperature (max) | 0C | 300 | 300 | 300 | 300 | 300 | - | - |
Temp rise ( T) in the heater | 0C | 25 | 25 | 25 | 25 | 25 | - | - |
Pressure at heater outlet | Kg/cm2 | 2.2 | 2.2 | 2.5 | 2.5 | 2.5 | - | - |
Flue gas duct diameter | mm | 250 | 300 | 300 | 350 | 450 | - | - |
Inlet / Outlet connection of heater | mm | 50 | 50 | 65 | 65 | 100 | - | - |
FUEL CONSUMPTION | ||||||||
Coal | Kgs/hr | 64 | 96 | 128 | 192 | 320 | - | - |
Wood | Kgs/hr | 87 | 130 | 174 | 260 | 435 | - | - |
ELECTRICAL LOAD | ||||||||
Thermic Fluid Pump Motor | Kw | 5.5 | 5.5 | 7.5 | 11.0 | 15 | - | - |
I.D. fan motor + F.D. fan motor | Kw | 1.5+0.375 | 2.2+0.75 | 2.2+0.75 | 3.7+1.5 | 5+2.2 | - | - |
Total Connected Load | Kw | 7.375 | 8.45 | 10.45 | 16.2 | 22.2 | - | - |