Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Thermal Shut Off Valves

Listing ID #4271228

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

This valve is installed in the down stream of sampling systems/heat exchanger. The valve responds only to temperature. Under the normal operation the valve is fully open. If the sample temperature....
View More Details
Send Enquiry

Company Information

  • Member Since 15 Years
  • Nature of Business Retailer
  • Year of Establishment 2003

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

This valve is installed in the down stream of sampling systems/heat exchanger. The valve responds only to temperature. Under the normal operation the valve is fully open. If the sample temperature increases within the operating temperature (120ºF), The thermal actuator modulates the valve to close the inlet orifice. The valve automatically opens as the thermal actuator cools. 
The heart of this valve is a solid to liquid phase change thermal actuator. The actuator contains Thermoloid® compound which changes phase from solid to a liquid as the temperature increases. As phase change occurs the volumes of Thermoloid® material changes significantly with the liquid volume greater than the solid volume. Since Thermoloid® is essentially incompressible under normal operating loads & it is sealed into a rigid actuator housing, only piston can move and extend as the volume increases. This motion is used to open or close the valve.

 

Features

  • AUTOMATIC: No reset or Operator involvement required

  • NO outside Power Source required

  • Rugged, Compact Design, Easy Installation, Fast response

  • Reliable Shut-off : Ram-type plug design provides tight seal upon shutoff

  • Operating temperatures unaffected by pressure

  • Wide Choice of Set points

  • Corrosion Resistant: Materials Stainless steel and Teflon to reduce contamination of Sample stream

  • Operates in any orientation

  • Maintenance free



Company Details close-icon

“A Leading manufacturer of Steam And Water Analysis System , Gas Sampling Systems, Chillers, Sample coolers, Pressure reducers, Shelters, Rectifier Cooling Systems , Turn-key Automation projects, & relevant accessories originally designed & selected throughout our 20 years of working experience in various instrumentation industries and latest know-how in this field.
These systems are designed in accordance with ASME PTC 19.11, ASME SEC VIII, Div. The sampling system (Wet Panel) designed by us does not require any power or external energy to operate. Due to this feature the maximum maintenance problems are eliminated.
The equipments manufactured by us are
Steam & Water Analysis system along with the analysers (SWAS),
Gas Sampling Systems, Steam Tracing Systems
Cooling Systems ( Chillers, Rectifier Cooling systems)
Sample coolers (shell & Tube Tyep & Coil - In-Coil Type)
High pressure sample filters,
Pressure Reducers (Diaphragm type, Piston Type, Rod-In-Tube Type)
Back pressure regulators,
Cation Columns (Resin Columns),
Pressure reducing stations & De-Superheating Stations, (PRS & PRDSH)
Automatic Blowdown Control Systems,
Sampling Probes, Multi-Valve Manifolds (5 valve, 3 valve, 2 valve,), High Pressure valves & Double Compression ferrule fittings (Steamlok)
Sample Sequencers (Micro-Processor based for Silica Analysers & Sodium Analysers)
Local Instrument Racks & Enclosures (LIE/LIR's)
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 20 - 50
  • Year of Establishment 2003
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Thermal Shut Off Valves?

Quantity
Seller Contact Details

Find Seller from near by Cities

Browse Related Categories

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice

Thermal Shut Off Valves

Listing ID #4271228

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

This valve is installed in the down stream of sampling systems/heat exchanger. The valve responds only to temperature. Under the normal operation the valve is fully open. If the sample temperature....
View More Details
Send Enquiry

Company Information

  • Member Since 15 Years
  • Nature of Business Retailer
  • Year of Establishment 2003

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

This valve is installed in the down stream of sampling systems/heat exchanger. The valve responds only to temperature. Under the normal operation the valve is fully open. If the sample temperature increases within the operating temperature (120ºF), The thermal actuator modulates the valve to close the inlet orifice. The valve automatically opens as the thermal actuator cools. 
The heart of this valve is a solid to liquid phase change thermal actuator. The actuator contains Thermoloid® compound which changes phase from solid to a liquid as the temperature increases. As phase change occurs the volumes of Thermoloid® material changes significantly with the liquid volume greater than the solid volume. Since Thermoloid® is essentially incompressible under normal operating loads & it is sealed into a rigid actuator housing, only piston can move and extend as the volume increases. This motion is used to open or close the valve.

 

Features

  • AUTOMATIC: No reset or Operator involvement required

  • NO outside Power Source required

  • Rugged, Compact Design, Easy Installation, Fast response

  • Reliable Shut-off : Ram-type plug design provides tight seal upon shutoff

  • Operating temperatures unaffected by pressure

  • Wide Choice of Set points

  • Corrosion Resistant: Materials Stainless steel and Teflon to reduce contamination of Sample stream

  • Operates in any orientation

  • Maintenance free



Company Details close-icon

“A Leading manufacturer of Steam And Water Analysis System , Gas Sampling Systems, Chillers, Sample coolers, Pressure reducers, Shelters, Rectifier Cooling Systems , Turn-key Automation projects, & relevant accessories originally designed & selected throughout our 20 years of working experience in various instrumentation industries and latest know-how in this field.
These systems are designed in accordance with ASME PTC 19.11, ASME SEC VIII, Div. The sampling system (Wet Panel) designed by us does not require any power or external energy to operate. Due to this feature the maximum maintenance problems are eliminated.
The equipments manufactured by us are
Steam & Water Analysis system along with the analysers (SWAS),
Gas Sampling Systems, Steam Tracing Systems
Cooling Systems ( Chillers, Rectifier Cooling systems)
Sample coolers (shell & Tube Tyep & Coil - In-Coil Type)
High pressure sample filters,
Pressure Reducers (Diaphragm type, Piston Type, Rod-In-Tube Type)
Back pressure regulators,
Cation Columns (Resin Columns),
Pressure reducing stations & De-Superheating Stations, (PRS & PRDSH)
Automatic Blowdown Control Systems,
Sampling Probes, Multi-Valve Manifolds (5 valve, 3 valve, 2 valve,), High Pressure valves & Double Compression ferrule fittings (Steamlok)
Sample Sequencers (Micro-Processor based for Silica Analysers & Sodium Analysers)
Local Instrument Racks & Enclosures (LIE/LIR's)
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 20 - 50
  • Year of Establishment 2003
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Thermal Shut Off Valves?

Quantity
Seller Contact Details

Find Seller from near by Cities

Browse Related Categories

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice