Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Temperature T-Logger

Listing ID #4146889

12,460 / Piece
Get Latest Price
  • user selectable, from 1 minute to 24 hoursCR2032 3V lithium ion / approximately 2 years
  • -30.0 to 70.0°C -22.0 to 158.0°F0.1°C 0.1°F
  • ±0.4°C (-20 to 60°C); ±0.6°C (outside) ±0.7°F (-4 to 140°C); ±1.1°F (outside)up to 4000 samples
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
Send Enquiry

Company Information

  • Member Since 16 Years
  • Nature of Business Retailer
  • Year of Establishment 2005

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

The HI143 T-Logger temperature dataloggers are housed in a smooth, yet tough watertight casing that is sealed against ingress of dust and water jets. They can be placed with goods on the move, on supermarket shelves and in warehouses. They record the temperature at a given interval to make sure that perishable goods are not left unattended, such as on a loading dock on the other side of the world. These dataloggers can provide that extra guarantee that goods never ventured out of limits of public safety.  

HI143 dataloggers can store up to 4,000 temperature samples in a password protected, non-volatile memory. The logging interval can be set from once per minute to once per 24 hour period; logging can be started through PC, the button on the face of the datalogger, or at a set time. The high and low alarm thresholds between logging intervals can also be stored. All of your collected data is password protected and tamper-proof. All parameters can be set through our Windows® compatible software through an RS232 or USB communication cradle.

 

Features at-a-glance

Locking Wall Cradle - A convenient wall cradle holds the HI143 T-Logger in place, whether it be on a truck or in a warehouse. A supplied lock and key help to further prevent tampering.

°C/°F Ranges - Through the PC application software, the HI143 can be programmed to read in Celsius or Fahrenheit.

LCD Display - The LCD clearly displays the status of the datalogger, the temperature reading and units, information regarding alarms, and battery level.

Data Logging - The HI143 can store up to 4,000 measurements at selectable intervals from 1 minute to 24 hours. Users can start logging through the PC software, the button on the face of the datalogger, or at a set time.

PC Connectivity - The HI143 can be controlled through a PC by simply placing the instrument on the supplied RS232 or USB communication cradle. A security password is able to be set to ensure collected data is tamper-proof when transferring and organizing logged data.

Programmable Alarms - High and low alarm thresholds can be programmed to alert users if the temperature readings go outside of the acceptable range.

Status Indicator Light - The LED light located on the cradle blinks to indicate that communication with the PC is active during data transfer.

Enhanced Battery Life - The HI143 series uses CR2032 3V lithium ion batteries to achieve a long battery life of about 2 years at 25°C.


Company Details close-icon

Hanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.
The HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, μg/L, mg/mL, M, mol/L, mmol/L, % w/v, user defined) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 1010.
Pressing the 'AutoHold' virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.
The log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.
Access help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.
The high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.
The compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 20 - 50
  • Year of Establishment 2005
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Temperature T-Logger?

Quantity
Seller Contact Details

Find similar products

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice

Temperature T-Logger

Listing ID #4146889

12,460 / Piece
Get Latest Price
  • user selectable, from 1 minute to 24 hoursCR2032 3V lithium ion / approximately 2 years
  • ±0.4°C (-20 to 60°C); ±0.6°C (outside) ±0.7°F (-4 to 140°C); ±1.1°F (outside)up to 4000 samples
  • -30.0 to 70.0°C -22.0 to 158.0°F0.1°C 0.1°F
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
Send Enquiry

Company Information

  • Member Since 16 Years
  • Nature of Business Retailer
  • Year of Establishment 2005

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

The HI143 T-Logger temperature dataloggers are housed in a smooth, yet tough watertight casing that is sealed against ingress of dust and water jets. They can be placed with goods on the move, on supermarket shelves and in warehouses. They record the temperature at a given interval to make sure that perishable goods are not left unattended, such as on a loading dock on the other side of the world. These dataloggers can provide that extra guarantee that goods never ventured out of limits of public safety.  

HI143 dataloggers can store up to 4,000 temperature samples in a password protected, non-volatile memory. The logging interval can be set from once per minute to once per 24 hour period; logging can be started through PC, the button on the face of the datalogger, or at a set time. The high and low alarm thresholds between logging intervals can also be stored. All of your collected data is password protected and tamper-proof. All parameters can be set through our Windows® compatible software through an RS232 or USB communication cradle.

 

Features at-a-glance

Locking Wall Cradle - A convenient wall cradle holds the HI143 T-Logger in place, whether it be on a truck or in a warehouse. A supplied lock and key help to further prevent tampering.

°C/°F Ranges - Through the PC application software, the HI143 can be programmed to read in Celsius or Fahrenheit.

LCD Display - The LCD clearly displays the status of the datalogger, the temperature reading and units, information regarding alarms, and battery level.

Data Logging - The HI143 can store up to 4,000 measurements at selectable intervals from 1 minute to 24 hours. Users can start logging through the PC software, the button on the face of the datalogger, or at a set time.

PC Connectivity - The HI143 can be controlled through a PC by simply placing the instrument on the supplied RS232 or USB communication cradle. A security password is able to be set to ensure collected data is tamper-proof when transferring and organizing logged data.

Programmable Alarms - High and low alarm thresholds can be programmed to alert users if the temperature readings go outside of the acceptable range.

Status Indicator Light - The LED light located on the cradle blinks to indicate that communication with the PC is active during data transfer.

Enhanced Battery Life - The HI143 series uses CR2032 3V lithium ion batteries to achieve a long battery life of about 2 years at 25°C.


Company Details close-icon

Hanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.
The HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, μg/L, mg/mL, M, mol/L, mmol/L, % w/v, user defined) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 1010.
Pressing the 'AutoHold' virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.
The log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.
Access help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.
The high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.
The compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 20 - 50
  • Year of Establishment 2005
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Temperature T-Logger?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice