Listing ID #3871785
Company Information
Ask for more detail from the seller
Contact SupplierStand alone unit after initial configuration of test parameters: The panel is capable to generate accurate test results for a continuous period of 28 days as required in the 28 days test
Cooling shall be provided by means of optimally placed Exhaust fans distributed all over to remove the hot air generated inside the panel cabinet
Power Loss Measurement available as an extra feature
Single / Three Phase operation possible
Servo controlled mechanism to control current (+/- 1%) against incoming fluctuations
Microcontroller based timer unit for quick and easy user interface and automated operation
Inductors with tapping for each range will be provided for maintaining the open circuit voltage to 30V. This eliminates energy wastage during test
User may opt for test bench with heating chamber for testing at 60 o C.
Â
SpecificationsÂ
Â
Â
Total current range 0 to 200 A
0.5A to 125A at 30V open circuit Voltage CT range 2A, 5A, 10A, 25A, 50A, 100A,200A
50 / 60 Hz operation as per incoming line frequency
Overall accuracy of the panel is better than class 1.0
Digital Temperature Indicator with input from thermocouple
Digital Volt Meter with 5 ranges (200mV, 2V, 20V, 200V, 250V) to measure open circuit voltage & mV drop across MCB
Digital Ammeter with CT (Indication on servo controller)
Class 1 Accuracy
Â