Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Stator Rotor Starter

    • ContactorAir break contractor confirming AC III
    • TimersElectronic timers to adjust no of steps and time delays
    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world

    We supply fully automatic combined stator and rotor starters type PRS that comprise of an air break contactor with over current and under voltage protection for the stator and set of accelerating....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 17 Years
    • building Nature of Business Manufacturer
    • gst icon GST No. 07AAXPS2966A1Z9

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    We supply fully automatic combined stator and rotor starters type PRS that comprise of an air break contactor with over current and under voltage protection for the stator and set of accelerating contactor along with automatic timing devices. These enable the motor to run up-to the speed in a pre-determined time. These are manufactured to conform to IS : 13947 Part-1 section 4 quality standards and are normally suitable for 15 operations per hour.


    Overload Relay:

    • Can be provided with either electro-magnetic oil dash pot time lag over current release or bimetallic type thermal relays
    • Give the necessary inverse time characteristics for protecting the connected equipment

     

    Resistance unit:

    • Can be either of nichrome round or fiat strip or cast stainless steel grids
    • Stainless steel grids are given for units above 100 HP
    • Wire wound resistances are supplied fro lower HP

     

    Controls:

    • Start, Stop and Reset push buttons, are provided on the front cover
    • Terminals are also provided for remote operation by outside signals.

     

    Isolator:

    • Can be fitted quick make and quick break isolators
    • Its operation can be interlocked with the front cover.

     

    Instruments and Cable Arrangements:

    • Provision is made for mounting metering instruments
    • Blank gland plates are provided for fixing cable glands

     

    Rating:

    • Standard ratings are up 40 HP  to 400 HP at 415V and 2000 HP at 6.6KV
    • Specific details regarding rotor volts and rotor currents should be supplied with the inquiries.


    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Stator Rotor Starter?