Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Speed-Cap (Load Operated) Power Factor Control System For Welding Applications

    • APFC Relay4 Stage APFC Relay with bank on/off LED Indication with measurement & calculations of all Electric
    • Operating modesAuto, Manual, Program, Standby mode.
    • Controller CurrentIN/5 Amp or IN/1 Amp. Single CT sensing.
    • Rated Voltage440/1-3 Phase/50Hz.
    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 5 Years
    • building Nature of Business Supplier

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • APFC Relay4 Stage APFC Relay with bank on/off LED Indication with measurement & calculations of all Electric
    • ProtectionsMCB/HRC FUSES To each Bank, With in built protections of APFC Controller.
    • Rated Voltage440/1-3 Phase/50Hz.
    • Operating voltage110/240/440V/1-3 Phase/50Hz
    • Operating modesAuto, Manual, Program, Standby mode.
    • Switching ElementThyristor Modules.
    • Controller CurrentIN/5 Amp or IN/1 Amp. Single CT sensing.

    LOAD OPERATED FAST RESPONSE REACTIVE POWER COMPENSATION SYSTEM :- . The system is designed to work automatically on highly variable, fluctuating, unbalanced loads. The compensation is done on percentage of load current set able on site in program mode of Controller with fast response with cut off of set value of power factor. Load operated Thyristor switched Automatic power factor system mainly suitable to Welding Loads, Lifts, Crane, Injection Molding Machines. It is a highly Fast response system properly designed to measure ,display, connect & disconnect the required Kvar Capacitors to achieve target power factor.

     

     

    Load operated APFC RELAY -Microprocessor based, most advanced device to measure & Display all electrical network parameters & calculate load Kvar to work automatically to connect & disconnect capacitors banks to achieve target power factor with ultra fast response.

     

    Display Parameters of APFC Relay:

     

    Voltage, Current, Power Factor, Active Power (KW), Apparent Power (KVA) -All at LT side

    Reactive Power (KVAR), Capacitive Reactive Power (KVAR)

    Active Energy (KWH), Apparent Energy ( Energy (KVAH), Reactive Energy(KVARH)

    Real Time, date, Network fault message display Capacitor bank status display,Load sideParameters viz. Current, P.F. & KVA.

    Protection :

     

             Controller offers protections in the following situations,

             High voltage , Low voltage, Over-load, Under load, Imbalance, Load Current

             Imbalance, Over Capacitor Current, Capacitor Current Imbalance, Over Temperature

     

    Programmable Parameters of APFC Relay:

    Target Power Factor - 0.90 lead to 0.85 lag.

    Time Delay (TD) - 0.5 mili sec - 120 Sec.

    CT Ratio - Current Transformer ratio to measure actual load.

    PT Ratio - Potential Transformer ratio to measure actual voltage.

    No. of Steps - 1 to 4 Capacitor steps.

    Capacitor Step Rating -on percentage of load current with connected Kvar.

    Display Scroll time delay.

    Capacitor's discharge time in Seconds.

    Compensation mode - fine-Avarage /minimum/maximum of load Kvar basis.


    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Speed-Cap (Load Operated) Power Factor Control System For Welding Applications?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice