Company Information
Ask for more detail from the seller
Contact SupplierWe are one of the professional manufacturers of Solar Pump Inverter. It has become the leading products combining photovoltaic industry with traditional industry such as agriculture water conservancy, desert control, daily water supply, city landscaping, etc. System is widely utilized for agriculture irrigation, desert control, pasture animal husbandry, City landscaping, daily water supply, etc. The offered inverter is manufactured by using premium quality components with the use of ultra-modern techniques under the guidance of our adept professionals.
Application Overview:Solar Pump Inverter, perfect solution to be free from power cuts. This pure solar inverter has peak efficiency and comes with in-built solar charge controller. With its slim design, solar pump inverter is suitable to install anywhere in your home and you can also run referigerator, cooler or air conditioner through this inverter. The advanced charging alogrithm, included monitoring software and built-in solar charge makes solar inverter a perfect solar inverter for any home.
SchemeAbove scheme does not show the interlocks for running the drive with three phase supply. External contactor logic will be required for changing from DC to AC supply.
Safety interlocks and isolator must be used to isolate the drive from PV source are not indicated in this scheme.
Drive selection: Sx2000 drive (400V class) drive as per motor rated current.
Total Vmpp = 560 to 610 VDC
Ex. If Vmpp of one panel = 30V then total panels required are 600 V / 30 V = 20 nos.
Under voltage level for 400V class drives is 360VDC Under voltage level for 200V class drives is 180VDC
Total Voc should not be higher than 760VDC
Impp = Motor kW * 1300 / Total Vmpp
Impp = Motor FLC * 0.75
Please select Impp whichever higher from above formulae.
Proper enclosure shall be selected based on the site conditions.
In case drive to motor cable distance is higher than 150-200 feet, an AC reactor shall be used at the output of drive.
Note:
If drive is required to be run on AC circuit then please refer technical manual of Sx2000 drive for AC side fuse ratings
I^2.t mentioned in above chart shall be referred, if different make of fuse is to be selected for the application.
Above ratings are for 400v class drives. Please contact beta for 200V class drives.
Terminologies Used:
MPPT: Maximum Power Point Tracking
Voc: Open circuit voltage of solar panels
We are looking for queries for Beta power Equipment from Tamil Nadu, Kerala, Karnataka & Andhra Pradesh,allover india and exports.
Vmpp: Voltage at Maximum Power Point
Impp: Current at Maximum Power Point