Contact SupplierSolar Inverter
Autonic iPower Series Power Conditioning Units
What is Autonic iPower Series Power Conditioning Unit?
Autonic iPower Series Power Conditioning Unit Complete solar power solution.
Pure sine wave-high frequency switched PWM inverter using toroidal core transformer for high overload capacity.
Absolutely no noise during operation and in loads, Utility grade output power quality.
Load operation optimized for solar energy utility.
Combined solar and grid charge with intelligent energy management and max solar energy utility by turning off grid charger if solar charger is ON.
Model | Autonic iPower Series – Bidirectional- Pure Sine Wave | ||||
Solar Input | Input voltage range | 40-56V DC | |||
Solar array voltage | Max Voc 90VDC | ||||
Continuous power | 1600W | ||||
Battery | Nominal battery voltage | 48V | |||
Max. battery voltage | Shut off @ >1.33 x V nom – Automatic restart @ < V max | ||||
Battery type select | VRLA and Flooded | ||||
Solar Charger | Type | PWM float | |||
Solar charger Current | Max 40 A | ||||
Grid | Grid Charging Capacity | 15 A Max | |||
Detection of the load | 8W min | ||||
Output voltage | Sine wave 230V | ||||
Frequency | 50Hz. | ||||
Distortion THD (resistive load) | <5% at Pnom | ||||
Protection | Overheat protection (+/-5°C) Shut down | Shut down @75°C-Auto-restart @ 70°C | |||
Overload and short circuit protection | Automatic disconnection with 5 time restart attempts | ||||
Reverse polarity protection | Hardware enabled – No fuse blow | ||||
Deep discharge battery protection | Shut off @ 0.87 x V nom – Automatic restart @ V nom | ||||
Temperature compensation | Cold-warm-hot levels | ||||
Display | LCD Display | 2 X 16 character display with auto back light | |||
Features | Intelligent Control | ||||
Grid Interaction | |||||
Password protected user settings | |||||
Indications & Alarms | Battery low warning level | ||||
Battery low disconnect level | |||||
Grid Charger FLOAT level | |||||
Battery low change over to Grid in timer mode | |||||
Inverter AC output voltage setting | |||||
Grid Charging current level | |||||
Solar charger float level | |||||
Solar charger minimum current for grid Charger ON | |||||
Grid window – wide and narrow level | |||||
Enable disable no load shutdown | |||||
Overload restart enable disable for narrow mode operation | |||||
Set RTC date and time. | |||||
Set ON and OFF time for backup operation | |||||
Monitoring Parameter | Grid Charging current level | ||||
Solar charger float level | |||||
Solar charger minimum current for grid Charger ON | |||||
Grid window – wide and narrow level | |||||
Enable disable no load shutdown | |||||
Overload restart enable disable for narrow mode operation | |||||
Set RTC date and time | |||||
Set ON and OFF time for backup operation |