SICAM FCM - Feeder Condition Monitor

Listing ID #4663136

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

the key to continuously improving power supply is essentially in depth knowledge of the relevant conditions of the local network. This is achieved through the use of all available sources connected....
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

the key to continuously improving power supply is essentially in depth knowledge of the relevant conditions of the local network. This is achieved through the use of all available sources connected to the system. Siemens offers a complete portfolio for network monitoring, power quality recording, fault recording, phasor measurement and system software application. Power quality and measurements supports power supply utilities and consumers with solutions required for the precise measurement, recording and reporting of the necessary distribution network data used to continuously determine, adapt and improve the power quality.sicam fcm the finger on the pulse of your distribution network sicam fcm (feeder condition monitor) is a short circuit and ground fault indicator with direction indication which uses protection algorithms and latest low power sensor technology according to iec 60044, yielding top results, particularly in isolated or compensated distribution networks.sicam fcm offers comprehensive measured values to monitor the load of distribution network components thus providing accurate data on the network condition. Live values, e.g. Of a transformer operated at overload, allow countermeasures to be taken in time such as load shedding or reducing the feedback power in the affected network segment. In order to correctly evaluate the condition of the distribution network, sicam fcm provides all relevant data via a modbus rtu interface.

device type

  • panel mounted device
  • polycarbonate, 96 x 48 x 119.5 mm (w x h x d)
  • spring-type terminals for all auxiliary connections
  • degree of protection ip20

input circuits

  • 3 inputs for alternating voltage configurable for 100v/√3 or 3.25v / √3 (according iec60044-7)
  • 3 inputs for alternating current for low-power sensor 225mv @ 300a (according iec60044-8)
  • alternative: input l2 configured for sensitive earth-fault detection using low-power sensors 225mv @ 60a (according iec60044-8)
  • ac 230 v
  • 1 fault status reset for external signal 24v upto 60v
  • battery for 2,000 hours, service life of approx. 20 years

signalization

  • big display to show live values or detailed fault information e.g. Fault direction
  • 1 red fault led to show status “fault detected”
  • 1 yellow com led to show communication running at the moment
  • 1 green run led to show health status of the sicam fcm itself

communication

  • interface rs485
  • modbus rtu communication for all information and remote configuration

measurands

  • trms (true rms) values for all direct measurements
  • phase voltages and currents
  • earth current
  • power frequency and cos ϕ
  • active, reactive and apparent power
  • 15 min average value for all phase currents
  • trailing pointer for currents

time synchronization

  • time synchronization via modbus rtu


Company Details close-icon

Siemens, Schneider, ABB, Alstom (GE)
Products Trading
1 Numerical Relays
2 Substation Automation Products
3 HT Switchgears & Spares
AIS Panels , GIS Panels Breakers , RMU , CSS etc.
4 HV Switchgears & Spares
5
LV Switchgears & Spares
1 Numerical Relays
2 LV Switchgears & Spares
1 HT Switchgears & Spares
AIS Panels , GIS Panels , Breakers , RMU , CSS etc.
Services
1 Gas Insulated Switchgear Panels Erection , Testing & commissioning
2 Air Insulated Switchgear Panels Erection , Testing & commissioning
3 All make Numerical Relays Testing & commissioning
(by Omicron Make Numerical Relay Test Kit)
4 Systems Study , Load Flow Study , Harmonic Study , Relay co-ordination
study
5 Transformer Testing & commissioning
TAN Delta , SFRA , Partial Discharge (PD) etc.
  • Nature of Business Manufacturer / Exporter / Service Provider / Supplier / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for SICAM FCM - Feeder Condition Monitor?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
SICAM FCM - Feeder Condition Monitor at Best Price in Navi Mumbai - ID: 4663136
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

SICAM FCM - Feeder Condition Monitor

Listing ID #4663136

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

the key to continuously improving power supply is essentially in depth knowledge of the relevant conditions of the local network. This is achieved through the use of all available sources connected....
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

the key to continuously improving power supply is essentially in depth knowledge of the relevant conditions of the local network. This is achieved through the use of all available sources connected to the system. Siemens offers a complete portfolio for network monitoring, power quality recording, fault recording, phasor measurement and system software application. Power quality and measurements supports power supply utilities and consumers with solutions required for the precise measurement, recording and reporting of the necessary distribution network data used to continuously determine, adapt and improve the power quality.sicam fcm the finger on the pulse of your distribution network sicam fcm (feeder condition monitor) is a short circuit and ground fault indicator with direction indication which uses protection algorithms and latest low power sensor technology according to iec 60044, yielding top results, particularly in isolated or compensated distribution networks.sicam fcm offers comprehensive measured values to monitor the load of distribution network components thus providing accurate data on the network condition. Live values, e.g. Of a transformer operated at overload, allow countermeasures to be taken in time such as load shedding or reducing the feedback power in the affected network segment. In order to correctly evaluate the condition of the distribution network, sicam fcm provides all relevant data via a modbus rtu interface.

device type

  • panel mounted device
  • polycarbonate, 96 x 48 x 119.5 mm (w x h x d)
  • spring-type terminals for all auxiliary connections
  • degree of protection ip20

input circuits

  • 3 inputs for alternating voltage configurable for 100v/√3 or 3.25v / √3 (according iec60044-7)
  • 3 inputs for alternating current for low-power sensor 225mv @ 300a (according iec60044-8)
  • alternative: input l2 configured for sensitive earth-fault detection using low-power sensors 225mv @ 60a (according iec60044-8)
  • ac 230 v
  • 1 fault status reset for external signal 24v upto 60v
  • battery for 2,000 hours, service life of approx. 20 years

signalization

  • big display to show live values or detailed fault information e.g. Fault direction
  • 1 red fault led to show status “fault detected”
  • 1 yellow com led to show communication running at the moment
  • 1 green run led to show health status of the sicam fcm itself

communication

  • interface rs485
  • modbus rtu communication for all information and remote configuration

measurands

  • trms (true rms) values for all direct measurements
  • phase voltages and currents
  • earth current
  • power frequency and cos ϕ
  • active, reactive and apparent power
  • 15 min average value for all phase currents
  • trailing pointer for currents

time synchronization

  • time synchronization via modbus rtu


Company Details close-icon

Siemens, Schneider, ABB, Alstom (GE)
Products Trading
1 Numerical Relays
2 Substation Automation Products
3 HT Switchgears & Spares
AIS Panels , GIS Panels Breakers , RMU , CSS etc.
4 HV Switchgears & Spares
5
LV Switchgears & Spares
1 Numerical Relays
2 LV Switchgears & Spares
1 HT Switchgears & Spares
AIS Panels , GIS Panels , Breakers , RMU , CSS etc.
Services
1 Gas Insulated Switchgear Panels Erection , Testing & commissioning
2 Air Insulated Switchgear Panels Erection , Testing & commissioning
3 All make Numerical Relays Testing & commissioning
(by Omicron Make Numerical Relay Test Kit)
4 Systems Study , Load Flow Study , Harmonic Study , Relay co-ordination
study
5 Transformer Testing & commissioning
TAN Delta , SFRA , Partial Discharge (PD) etc.
  • Nature of Business Manufacturer / Exporter / Service Provider / Supplier / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for SICAM FCM - Feeder Condition Monitor?

Quantity
Seller Contact Details

Find similar products

View all products in Monitors

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice