Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

3.3 in x 3.3 in x 2.2 in ShockLog 248 Impact Recorder

Listing ID #6867312

1.10 Lakh - 1.15 Lakh / Piece
Get Latest Price
  • MOQ 01 Piece
  • Size3.3 in x 3.3 in x 2.2 in
  • Weight1.1 lbs (without battery)
  • Warning and Alarm Threshold (% of Range)11–95%
  • Operating Temperature Range-40°F to 185°F
  • Supply Type Manufacturer, Exporter, Supplier, Retailer, Distributor
  • Preferred Buyer Location Anywhere in India
View More Details
Send Enquiry

Company Information

  • Member Since 1 Year
  • Nature of Business Trader
  • GST No. 07AAFCS9627M1ZP

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Size 3.3 in x 3.3 in x 2.2 in
  • Operating Temperature Range -40°F to 185°F
  • Acceleration Range (Factory Set) +/- 10G; +/- 30G; +/- 100G
  • Scale Factor +/- 2%
  • Battery One (1) 3.6V Lithium Thionyl Chloride OR One (1) 1.5V Alkaline Size AA
  • Cut-off Frequency Options 40 Hz; 90 Hz; and 250 Hz
  • FEATURES Record impact events, User-definable alarm levels, iButton® and USB data transfer options.
  • Weight 1.1 lbs (without battery)
  • Battery Life 12 months
  • APPLICATIONS Robotics, Logistics / Transport and Storage, Construction – Supplies and Fixtures, Metal Fabrication
  • Humidity 0–100% RH
  • Warning and Alarm Threshold (% of Range) 11–95%
  • Temperature -40°F to 185°F
  • Dew Point -40°F to 185°F; 0–100% RH
  • Wake-Up Time 0.25 mS

Imperial
Operating Temperature Range -40°F to 185°F
Size 3.3 in x 3.3 in x 2.2 in
Weight 1.1 lbs (without battery)
Battery One (1) 3.6V Lithium Thionyl Chloride OR One (1) 1.5V Alkaline Size AA
Battery Life 12 months
Scale Factor +/- 2%
Acceleration Range (Factory Set) +/- 10G; +/- 30G; +/- 100G
Cut-off Frequency Options 40 Hz; 90 Hz; and 250 Hz
Warning and Alarm Threshold (% of Range) 11–95%
Wake-Up Time 0.25 mS
Humidity 0–100% RH
Temperature -40°F to 185°F
Dew Point -40°F to 185°F; 0–100% RH
Metric
Operating Temperature Range -40°C to 85°C
Size 84 mm x 84 mm x 55 mm
Weight 445g (without battery)
Battery One (1) 3.6V Lithium Thionyl Chloride OR One (1) 1.5V Alkaline Size AA
Battery Life 12 months
Scale Factor +/- 2%
Acceleration Range (Factory Set) +/- 10G; +/- 30G; +/- 100G
Cut-off Frequency Options 40 Hz; 90 Hz; and 250 Hz
Warning and Alarm Threshold (% of Range) 11–95%
Wake-Up Time 0.25 mS
Humidity 0–100% RH
Temperature -40°C to 85°C
Dew Point -40°C to 85°C; 0–100% RH
Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

SRV Damage Prevention is a diversified dynamic young company that started its operations in March 2002 and is headquartered in Delhi, India. SRV focuses on reducing the transit damage caused to goods during storage, handling, and shipping.
We are the only exclusive distributor of Shockwatch Inc (Now Spotsee), headquartered in Dallas, Texas (US) for India, the Middle East, and South East Asia. We import products such as Tilt indicators, Temperature indicators, and Recorders, Shock/Impact Indicators, and Recorders from Spotsee. SRV is the master distributor of a variety of Safety cutters from Slice Inc, California (US) and Adco Industries, Dallas Texas (US).
SRV has been privileged to work with the majority of fortune 500 companies covering all sectors of industries mainly FMCG, Pharmaceutical, Bio Medial, Automotives, Power and Energy, Aerospace, Defence Manufacturing, and High-end electronics, etc
  • Nature of Business Manufacturer / Service Provider / Supplier / Distributor / Importer / Trader
  • Number of Employees Below 20
  • Year of Establishment 2002
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for ShockLog 248 Impact Recorder?

Quantity
Seller Contact Details

Find Seller from near by Cities

Browse Related Categories

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
3.3 in x 3.3 in x 2.2 in ShockLog 248 Impact Recorder at Rs 110000 in Delhi - ID: 6867312
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

3.3 in x 3.3 in x 2.2 in ShockLog 248 Impact Recorder

Listing ID #6867312

1.10 Lakh - 1.15 Lakh / Piece
Get Latest Price
  • MOQ 01 Piece
  • Size3.3 in x 3.3 in x 2.2 in
  • Temperature-40°F to 185°F
  • Battery Life12 months
  • Weight1.1 lbs (without battery)
  • Supply Type Manufacturer, Exporter, Supplier, Retailer, Distributor
  • Preferred Buyer Location Anywhere in India
View More Details
Send Enquiry

Company Information

  • Member Since 1 Year
  • Nature of Business Trader
  • GST No. 07AAFCS9627M1ZP

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Size 3.3 in x 3.3 in x 2.2 in
  • Wake-Up Time 0.25 mS
  • APPLICATIONS Robotics, Logistics / Transport and Storage, Construction – Supplies and Fixtures, Metal Fabrication
  • Cut-off Frequency Options 40 Hz; 90 Hz; and 250 Hz
  • Battery Life 12 months
  • Operating Temperature Range -40°F to 185°F
  • Dew Point -40°F to 185°F; 0–100% RH
  • Warning and Alarm Threshold (% of Range) 11–95%
  • FEATURES Record impact events, User-definable alarm levels, iButton® and USB data transfer options.
  • Temperature -40°F to 185°F
  • Humidity 0–100% RH
  • Scale Factor +/- 2%
  • Weight 1.1 lbs (without battery)
  • Acceleration Range (Factory Set) +/- 10G; +/- 30G; +/- 100G
  • Battery One (1) 3.6V Lithium Thionyl Chloride OR One (1) 1.5V Alkaline Size AA

Imperial
Operating Temperature Range -40°F to 185°F
Size 3.3 in x 3.3 in x 2.2 in
Weight 1.1 lbs (without battery)
Battery One (1) 3.6V Lithium Thionyl Chloride OR One (1) 1.5V Alkaline Size AA
Battery Life 12 months
Scale Factor +/- 2%
Acceleration Range (Factory Set) +/- 10G; +/- 30G; +/- 100G
Cut-off Frequency Options 40 Hz; 90 Hz; and 250 Hz
Warning and Alarm Threshold (% of Range) 11–95%
Wake-Up Time 0.25 mS
Humidity 0–100% RH
Temperature -40°F to 185°F
Dew Point -40°F to 185°F; 0–100% RH
Metric
Operating Temperature Range -40°C to 85°C
Size 84 mm x 84 mm x 55 mm
Weight 445g (without battery)
Battery One (1) 3.6V Lithium Thionyl Chloride OR One (1) 1.5V Alkaline Size AA
Battery Life 12 months
Scale Factor +/- 2%
Acceleration Range (Factory Set) +/- 10G; +/- 30G; +/- 100G
Cut-off Frequency Options 40 Hz; 90 Hz; and 250 Hz
Warning and Alarm Threshold (% of Range) 11–95%
Wake-Up Time 0.25 mS
Humidity 0–100% RH
Temperature -40°C to 85°C
Dew Point -40°C to 85°C; 0–100% RH
Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

SRV Damage Prevention is a diversified dynamic young company that started its operations in March 2002 and is headquartered in Delhi, India. SRV focuses on reducing the transit damage caused to goods during storage, handling, and shipping.
We are the only exclusive distributor of Shockwatch Inc (Now Spotsee), headquartered in Dallas, Texas (US) for India, the Middle East, and South East Asia. We import products such as Tilt indicators, Temperature indicators, and Recorders, Shock/Impact Indicators, and Recorders from Spotsee. SRV is the master distributor of a variety of Safety cutters from Slice Inc, California (US) and Adco Industries, Dallas Texas (US).
SRV has been privileged to work with the majority of fortune 500 companies covering all sectors of industries mainly FMCG, Pharmaceutical, Bio Medial, Automotives, Power and Energy, Aerospace, Defence Manufacturing, and High-end electronics, etc
  • Nature of Business Manufacturer / Service Provider / Supplier / Distributor / Importer / Trader
  • Number of Employees Below 20
  • Year of Establishment 2002
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for ShockLog 248 Impact Recorder?

Quantity
Seller Contact Details

Find Seller from near by Cities

Browse Related Categories

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice