Contact Supplierseries flst duct mounted airflow measurement station
rectangular, oval or circular configurations
the series flst airflow measurement station is easy to install -- simply connect the tubing to the station fittings, then to a differential pressure manometer, gage, transmitter or switch. Single or multiple airflow elements are factory mounted and pre-piped in a casing designed for flanged connection to the duct work. Standard materials consist of a g90 galvanized casing and 6063-t5 anodized aluminum flow sensors, suitable for most hvac applications.
the series flst utilizes an airflow averaging element in a head-type device, generating a differential (velocity) pressure signal similar to the orifice, venturi, and other had producing primary elements. Strategically located sensing ports continually sample the total and static pressures when inserted normal to flow.
total pressure sensed by the upstream ports are continually averaged within the airflow element in an isolated chamber. The static sensing ports are averaged in a second isolation chamber. Multiple elements are joined together for connection to a differential measurement device (gage, transmitter, etc.) for flow measurement and indication purposes.
product applications
building air intake and exhaust flow rate measurement
hvac air flow measurement
specifications
accuracy:within 2% of actual flow when installed in accordance with published recommendations.
k-factor:0.97.
velocity range:100 to 10,000 fpm (0.51-51 m/s).
wetted materials:elements: 6063-t5 anodized aluminum; casings: 16 ga g90 galvanized steel.
temperature limits:galvanized casings and aluminum elements: 350°f (177°c) continuous operation (in air) 400°f (204°c) intermittent operation (in air).
humidity:all airflow stations 0 to 100% non-condensing.
process connections:1/4" compression fittings.
features
low signal-to-noise ratio
factory mounted and pre-piped in a flanged duct section (casing)
standard construction includes galvanized casing and 6063-t5 anodized aluminum flow sensors
standard airflow stations can be operated (in air) continuously in temperatures up to 350°f or intermittently in temperatures up to 400°f
related products
series ms magnesense® differential pressure transmitter
series ms magnesense® differential pressure transmitter
series afg averaging flow grid
series afg averaging flow grid
series dh3 digihelic® differential pressure controller
series dh3 digihelic® differential pressure controller
series adps/edps differential pressure switch
series adps/edps differential pressure switch
series stra duct mounted airflow measurement station
series stra duct mounted airflow measurement station
series pafs-1000 averaging flow sensor
series pafs-1000 averaging flow sensor
use : hvac air flow measurement
color : silver
material : elements: 6063-t5 anodized aluminum; casings: 16 ga g90 galvanized steel.
certification : yas
condition : new
type : building air intake and exhaust flow rate measurement
display type : analog
features : easy to fit, perfect strength