  • Preferred Buyer Location All over the world

Material of gas-conducting partsPVDF, PTFE, PVC, EPDM, FPM, NovoprenePower supplyInput voltage230 V (207...250 V) AC, 50 Hz or 60 Hz ± 2 Hz115 V (100...135 V) AC, 50 Hz or 60 Hz ± 2 HzPower....
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Material of gas-conducting parts
PVDF, PTFE, PVC, EPDM, FPM, Novoprene
Power supply
Input voltage
230 V (207...250 V) AC, 50 Hz or 60 Hz ± 2 Hz
115 V (100...135 V) AC, 50 Hz or 60 Hz ± 2 Hz
Power consumption during operation
Diaphragm pump approx. 50 VA,
metering pump approx. 3.5 VA 
Construction
Design: Surface-mounting housing 1/2 19 inch, 6 height units
Mounting: On the wall with the mounting brackets supplied or in a 19 inch cabinet / rack
Housing material and color: Sheet steel; light gray (RAL 7035), basalt gray (RAL 7012)
Degree of protection of housing: IP 20 to EN 60529 
Gas Connections
PVDF coupling for tube of 6 x 4 x 1 mm
Electrical connections
Power supply: Screw clamp terminals for stranded or solid wire with max. 1.5 mm2
Status signals: Screw clamp termin max. 1.5 mm2
Electrical safety
Testing to EN 61010-1
Protective class: I
Overvoltage category / degree of contamination: III / 2
Protective separation: Electrical isolation of the 115 / 230 V AC power supply from the other current circuits by means of reinforced or double insulation. Functional extra-low voltages (PELV) on the low voltage side 
Electromagnetic compatibility
Radio interference suppression: Class B to EN 55011
Interference immunity: Testing to EN 50082-2 
Mechanical capabilities
Testing to EN 60068-2-27 and EN 60068-2-6
Transport: 
Shock: 30 g / 18 ms / 18 shocks
Vibration: 1 g / ±0.15 mm / 5...150 Hz, 3 x 5 cycles
Operation
Vibration: 1 g / ±0.07 mm / 5...55 Hz, 3 x 2 cycles 
Ambient conditions
Ambient temperature
Operation: +10...+50 °C,
Storage and transport: –25...+60 °C
Relative humidity
= 75 % annual average, occasional and slight condensation
permitted, = 90 % on 30 days/year
Options 
Metering unit 
By means of peristaltic pump, flow rate 15 ml/h, feed tank as accessory 
for small SO2 measuring ranges (< 1000 mg/m3) or to avoid acid aerosols
I/O card 
To connect the SCC-F sample gas feed unit and the SCC-C sample gas cooler to the AO2000 Series continuous gas analyzers via the system bus
– Display and monitoring of the cooler temperature
– Monitoring and processing of status signals of the SCC-F sample gas feed unit (condensate, flow rate)
– Control of an external solenoid valve for zero gas connection, 230 V, 50 Hz
– Digital inputs for monitoring condensate collecting bottles and reagent reservoirs
CSA certification
The SCC-F sample gas feed unit is certified to
– Class 2258 02 Process Control Equipment – For Hazardous
Locations and
– Class 2258 82 Process Control Equipment – For Hazardous
Locations – Certified to U.S. Standards
Class 1, Div. 2, Groups A, B, C and D, Temperature Code T4,
Maximum Ambient Temperature +50 °C.
Approval includes testing per applicable Canadian (CSA) and
US directives.
Certificate No. 1105720 



Company Details close-icon

We introduce our selves as manufacturer and Supplier of the Various types of SAMPLE HANDLING SYSTEM for Gas Analyzer's. (Measuring CO, CO2, O2, H2, CH4, NO, NH3 gases etc).
We are having Recharging/Refilling facility for CO/CO2/CH4/NO/NH3 DETECTORS/RECEIVER of NDIR based Gas Analyzers (make: ABB, H&B, Siemens, Rosemount, IL etc) with one Year performance WARRANTEE.
We work on AMC for the System also, as we are in the field of Commissioning/Servicing/OH and Calibration of different types of Gas Analyzers for the last about 16 years.
In brief we are supplying the following SPARES of Sampling System:
Sampling System
Complete system on turn key bases for Kiln Inlet, Pre-Heater, Pre-calciner, Coal Mill etc-2.
Gas Analyzer System:
CO/CO2/O2/NO/H2/CH4/NH3/SO2 gas measurement.
Online Analyzer: ABB & Siemens make (Germany)
Portable Analyzer: KANE make (England)
Spare Parts for Analyzer
ABB Advance Optima, URAS 14/26, Magnos 17/27/206, Caldos 15/17, URAS 2T, 3G, 4, 10P, 10E, Magnos 5T, 2T, 3, 7G, 6G, 4G, Caldos 4T, 4, Lima 11, Radas 1G, 2, Siemens Oxymat 61, 64, Ultramat 23, Calomat, Fidamat, Rosemount etc-2.
Optical Parts: Radiator Unit, Sample Cell, Filter Cell, Receiver/Detector, Calibration Cell, Pressure Sensor Board, Analyzer Module, Ring Sensor O2, Digital Display etc.
Electronics: Syscon 2 Boards, IR Board, Sensor CPU Board, Memory Card, RAM Card, I/O Board, , Amplifier Card, Supply Card, Temperature Card, Analyzer Card. Transformer, Blowers, Temp. Sensor, NTC etc-2
Dust Measuring Inst.
Particle Flow Meters, Dust Flow Measuring Devices, Dust Measuring Instruments (Made in Germany).
Gas Sampling Probes
Probe-4 (800°C), Probe 5 with Porcelain (1200°C), Water Cooled Probe13 & Probe 60 (1300°C), Water Cooled Twin Gas Sampling Probe (PWT-2) 1300°C, Probe 2, Air Probe 1 (500°C) and Others on request.
Retraction System
Auto/Manual Retraction System with Electric Motor or Pneumatic Motor and Control Cabinet for Probe 13, Probe 60, PWT-2 twin Probe.
Heaters
Ring Heater / Heating Device 220V/110V, Peltier Heater.
Sample Gas Cooler
Peltier Sample Gas Cooler (with imported cooling element USA make), Electric Sample Gas Cooler with SS cooling coil (Model: CGEK-5) Compressor Type, ABB make SCC-C, Water Coolers etc-2.
Vacuum Pumps
Diaphragm Pump model: DP-2, KNF 3N(motorized), SE-30, Heavy Duty Diaphragm Pump model: SE 010/TD-45/TD10, Peristaltic Pump for condensation removal, Centrifugal Pump for Close Loop Water Circulation.
Spare Kits
Spare kit for Pump DP-2/3N/SE-30/SE 010/ TD10/TD-45, KNF make pumps, Centrifugal Pump, Peristaltic Pumps & Dosing Pump etc. Repairing of all types of Vacuum Pumps can be done.
Heat Exchanger
For Water Cooling System for Kiln Inlet Probe with Fan & Motor.
Filters
Ceramic Filter for Probe 4, 13, 60, Universal Filter(glass wool), Sintered Filter(Bronze), Filter with Catch Pot (SS), Diaphragm filter (SS/PVC), GFDF Filter Paper(2µ), Condensate Monitor with switching unit ER-144, Water Filter (SS), Air Filter, Gas Filter, Acid Filter & Acid Filter Element, GFDF - Thimble, Disposable Filter etc.
Scavenging System
Auto/Manual Scavenging & Purging System for Probes with PLC.
Flow Meters
Flow meter 7-70 or 10-100 lph, Flow Guard/Controller (FM+Sensor+Relay) For Air & Water.
Acc. for Analyzer Panel
PLC, Scavenging System, 5-way calibration valve, Needle Valve, 2 Way Valve, Solenoid Valves, Gas Filter, Drying Tower, Catch Pot, Sample Gas Feed Unit (SCC-F), Cooling Fan, Air Filter Station, Water Filter Station, Radiator Unit for Heat Exchanger, Power supply(24V, 5A), Power Transformer, Timers, Circuit Breaker, Silicon/ PVDF/ Viton/ PVC/ Nylon Air Tubes, SS/PTFE Panel Fittings etc.
Tubes / Hose Pipes
Teflon / PTFE Tubes, Air Tube, Water Hose, Steam Pipes.
Miscellaneous
RTD, Thermocouple, Solenoid Valves, Dust Monitor, CCTV, Capacitive Level Controller, IP/PI Converters, Transducers, 8pin 11pin Relay Base, OEN Relay, Zerconia Probe and their Spares, Temperature Controller, Temp. Scanner, Pressure Equalizer, Pressure Gauge etc.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Sample Gas Feed Unit?

Quantity
Seller Contact Details

Browse Related Categories

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice