Automatic Mild Steel Digital pH Meter for Indsustrial Usage

Listing ID #1897509

  • MOQ 10 Piece
  • Body MaterialMild Steel
  • ColorSilver
  • Automatic GradeAutomatic
  • Power SourceElectric
  • Supply Type Exporter, Supplier
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 16 Years
  • Nature of Business Manufacturer
  • GST No. 24AYTPS1105M1Z2

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Body Material Mild Steel
  • Color Silver
  • Automatic Grade Automatic
  • Power Source Electric
  • Application Indsustrial Usage
  • Certification CE Certified
  • Feature Accuracy, Durable, Light Weight, Low Power Comsumption, Stable Performance
  • Display Type Digital
  • Type Digital Ph Meters
  • Country of Origin India

A digital pH meter is an electronic instrument used to measure the acidity or alkalinity of a liquid. It measures the concentration of hydrogen ions (H+) in the liquid, which determines its pH level. A lower pH indicates a more acidic solution, while a higher pH indicates a more basic or alkaline solution. Here's a detailed explanation of digital pH meters with their specifications:

Components of a Digital pH Meter:

· Electrode: The most crucial component, it consists of a glass bulb that is sensitive to hydrogen ions. The bulb is filled with a reference solution and has a silver chloride (AgCl) reference electrode in contact with the solution. When the electrode is submerged in a liquid, an electrical potential is generated between the reference electrode and the hydrogen ions in the liquid.

 

Digital PH Meter Electrode

· Reference Electrode: Maintains a stable electrical potential within the meter.

· Converter: Converts the electrical signal from the electrode into a pH reading.

· Display: Shows the measured pH value in a digital format.

· Temperature Probe (Optional): Some meters have a built-in temperature probe to account for temperature variations that can affect pH readings.

· Calibration Solutions: Buffers with known pH values used to calibrate the meter for accurate readings.

Specifications to Consider When Choosing a Digital pH Meter:

· pH Range: The range of pH values the meter can measure (typically from 0 to 14 pH).

· Accuracy: The level of precision in the pH readings (usually specified in ±pH units).

· Resolution: The smallest difference in pH that the meter can detect (often 0.01 pH or 0.1 pH).

· Calibration: The number of calibration points the meter allows (typically 1 to 3 points). More calibration points generally improve accuracy.

· Temperature Compensation: Automatic or manual adjustment for temperature variations affecting readings.

· Data Logging and Memory (Optional): Some meters can store readings for later analysis or transfer to a computer.

· Electrode Type: Consider refillable, gel-filled, or solid-state electrodes depending on your needs and budget. Refillable electrodes offer higher accuracy but require more maintenance.

· Durability and Portability: Think about the meter's housing material, weight, and portability for your application.

Applications of Digital pH Meters:

· Hydroponics and Gardening: Monitoring nutrient solution pH for optimal plant growth.

· Swimming Pools and Spas: Maintaining proper pH levels for disinfection and swimmer comfort.

· Aquariums: Ensuring suitable pH levels for fish and aquatic life.

· Food and Beverage Industry: Monitoring pH during food processing and production to ensure quality and safety.

· Chemical Industry: Measuring pH levels in various chemical solutions for control and analysis.

· Environmental Monitoring: Testing the pH of water bodies to assess water quality.

· Scientific Research: Measuring pH in various experiments and investigations.

Using a Digital pH Meter:

1. Calibrate the meter with standard buffer solutions according to the manufacturer's instructions.

2. Turn on the meter and allow it to warm up if necessary.

3. Rinse the electrode with distilled water and blot it dry with a lint-free paper.

4. Immerse the electrode in the liquid to be measured.

5. Stir the liquid gently to ensure good contact with the electrode.

6. Wait for the reading to stabilize on the display.

7. Record the pH reading and rinse the electrode again for storage.

Here are some additional tips for using a digital pH meter:

· Always follow the manufacturer's instructions for your specific meter model.

· Use fresh calibration buffers regularly.

· Store the electrode properly in the recommended storage solution when not in use.

· Clean the electrode regularly according to the manufacturer's recommendations.

By understanding the specifications and proper use of digital pH meters, you can ensure accurate and reliable pH measurements in various applications.


Additional Information

  • Payment Terms T/T
  • Port of Dispatch Any
  • Packaging Details Any
  • Delivery Time Any
Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

We herewith introduce our selves as a manufacturer & exporters of process control instruments & factory automation systems Since 2007, We provide
Turnkey projects
Solution provider
System integrator
Mechanical and flow control
Flow metering packages
Electrical equipments
Panel building
Building automation services
Instrumentation and automation.
  • Nature of Business Manufacturer / Exporter / Service Provider / Supplier
  • Number of Employees Below 20
  • Year of Establishment 2007
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Digital pH Meter?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice