Specifications:
Rotary Kiln (Rotataing Cylinder)
Combustion efficiency is at least 99%.
Combustion Chamber
Temperature of primary chamber is minimum of 800°C-1500°C and the secondary chamber is....
Temperature of primary chamber is minimum of 800°C-1500°C and the secondary chamber is minimum 1200°C -1900°C.
The secondary chamber gas residence time at least two seconds.
Capacity: 500/1000/1500/2000 Kg/Hr.
Air Pollution control device
Wastes to be incinerated are not chemically treated with any chlorinated disinfectants.
Ash from incineration of waste is disposed of at common hazardous waste treatment and disposal facility. However, it may be disposed of in municipal landfill, if the toxic metals in incineration ash are within the regulatory quantities.
Power Requirement: LPG, N-Gas, Diesel, Electrical
Features:
To maintain designed heat capacity of the kiln, quantity of the solid waste injection package (kg/single injection) shall be adjusted w.r.t. calorific value of the waste feed.
When a high calorific value possessing solid waste is injected in packets, the size of each injection may be reduced, such that the peak CO concentration in the Kiln does not exceed too high in the initial stage, creating shooting of emissions to the secondary chamber, thereby crisis in ensuring the required retention time.
Appropriate slope (in general, 3 degrees), rotation rates and solid waste residence time (1-10 hrs) may be adjusted for the kilns, in order to achieve total organic carbon (TOC) and loss on ignition (LOI) requirements in the ash/slag.
To ensure life of refractory and insulation bricks, it is a practice to feed silica and glass in appropriate ratios to the kilns to form a cover over the refractory lining, as and when the thickness of the layer reduces.
It has been reported that reduction of out-side surface temperature of the rotary kiln enhances the life of refractory bricks and lining. Thus may be explored, where feasible.
In the rotary kiln, the temperature shall be maintained at 800+°C in order to ensure complete burning of solid waste. Controlled flow of air shall be maintained for complete volatilization of solid waste.
Ash removal doors are provided in the primary, secondary and settling chambers.
Temp. Indicator for Scrubber and stack ON/OFF switches, fuses, sensors, hooter etc. complete with in all respectfully lined with refractory materials and fitted with high quality packing to seal the door.
Primary Rotating Chamber (keeps rotating at a low speed to ensure excellent quality of incineration).
Rotary incinerator equipped with feeder bucket elevator/ram feeder and conveyor for continuous waste feeding.
Static Secondary Chamber
Material of Construction – Heavy duty steel with higher thickness used in kiln and structures fabrication for extremely long life.
Insulated and Refractory lined chambers
Emergency stack to vent out the gases in case of power failure
Various types of Air Pollution Control Devices (Quencher, Venturi Scrubber, Packed Bed Scrubber, Bag House Filtration system with Teflon Bags, Bag House Filtration system with Ceramic Filters).
F D Fan for providing air inside the chambers.
I D Fan to maintain the negative draft and control the gas flow
Fuel Oil Tank & Piping
Electrical Control Panel
Interconnecting ducts & piping
Chimney of 5/10/15/30 mtrs height from ground level OR as per country’s regulation and client’s requirement
Environment Friendly
Company Details
Microteknik was founded in 1967. At its inception the company manufactured many type of pathology and histopathology. In 1973, Microteknik was established as a full fledge Manufacturing unit with a facility for pathology, histopathology, Microscopes, audiovisual, pharmacology, pharmacy and anatomy instruments comparable to any International Standard. Later we added in 1992 Clean air systems, Heat and refrigeration ( from -80 to 2200 deg),seed technology were added following with analytical instruments and glassware incinerator, fermenters, lyophilizers in 2002. Awarded with national excellence award and last addition Engineering college instruments in 2005. We own our gratitude to Sh. V.B.Jain, the founder of the organization who’s prolonged striving endeavor for perfection, strenuous and sustained R & D coupled with relentless efforts to incorporate latest technology all these years, has made it possible to grade ‘TEKNIK’ products “an embodiment” for quality and streamlined designing and accuracy. We are also indebted and to our clients-the dealers and actual end-user for the patronage extended and for the continuous confidence reposed in us and for valuable suggestions to further improve quality of some our products. Our R & D section also deserves a Mention for their constant tireless efforts to bring -out instruments with latest technological adaptations making some of our product as import as import Substitute. All our instruments are warranted for 12 months against any manufacturing or working defects expect breakage or mishandling. An effective After Sale Service exists. The Latest illustrated section-wise Catalog and Consolidated and Consolidated Price List, we fervently hope , shall find your favorable response. Microteknik believes that the customer is supreme and quality always comes first. The Company believes in perfection in workmanship and believes in providing their customer everywhere with products of quality as is evident from best performance and beautiful sturdy designs.We are Looking Enquiries from Asia, Europe, Middle east, Africa, North America, South America & Australia.