Specifications

Model RESQ30GT33 RESQ40GT33 RESQ60GT33 RESQ80GT33 RESQ100GT33 RESQ120GT33 RESQ160GT33 RESQ200GT33
Capacity 30KVA/24KW 40KVA/32KW 60KVA/48KW 80KVA/64KW 100KVA/80KW 120KVA/96KW 160KVA/128KW 200KVA1160KW
Output
Nominal Voltage 3 x 380VAC/400VAC (3Ph N)
Acceptable Voltage Range 285VAC - 475VAC
Frequency 50/60 Hz ± 10 %
Inverter
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Precision Stationary ± 1% Transitory: t5% (load variations 100% - 0% - 100%)
Frequency 50/60 He synchronised ±1 %With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) <5% (Non-linear Load)
Phase Displacement 120° ± 1% (balanced load) 120°± 2% (imbalances upto 50% of the load)
Dynamic Recovery Time 3 cycles at 90 % of the static value
Admissible Overload 110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load Current Limit <1%
Current Limit High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit
Static Bypass
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
Maintenance Bypass
Type Without interruption
Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency
Line Mode 90.00% 91.00% 92.00%
Battery Mode 91.00% 92.00% 93.00%
Battery & Charger
Battery Type and Numbers 12VDC x 32 pcs (29-32 p. adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current *Default 10A; Maximum 40A; 5A@ full load
Charging Voltage 432 VDC (Based on 32pcs batteries)
Physical
Dimensions, D X W H(mm) 656x405x941 821x432x1159 975x554x1286 975x554x1326 1051x705x1646
Net weights (kgs) 193 278 365 471 573 650 760 840
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for RESQ GT 33 Online UPS System?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
RESQ GT 33 Online UPS System at Best Price in Jamshedpur - ID: 4488984
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

RESQ GT 33 Online UPS System

Listing ID #4488984

  • Condition :New
  • Application:Residential,Commercial
  • Phase:Single Phase,Three Phase
  • Weight:Upto 35 Kg
  • Form Factor:Tower Model
  • Supply Type Supplier
  • Preferred Buyer Location India ( Jharkhand )
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer
  • GST No. 20FZFPS5310N1Z8

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Specifications

Model RESQ30GT33 RESQ40GT33 RESQ60GT33 RESQ80GT33 RESQ100GT33 RESQ120GT33 RESQ160GT33 RESQ200GT33
Capacity 30KVA/24KW 40KVA/32KW 60KVA/48KW 80KVA/64KW 100KVA/80KW 120KVA/96KW 160KVA/128KW 200KVA1160KW
Output
Nominal Voltage 3 x 380VAC/400VAC (3Ph N)
Acceptable Voltage Range 285VAC - 475VAC
Frequency 50/60 Hz ± 10 %
Inverter
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Precision Stationary ± 1% Transitory: t5% (load variations 100% - 0% - 100%)
Frequency 50/60 He synchronised ±1 %With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) <5% (Non-linear Load)
Phase Displacement 120° ± 1% (balanced load) 120°± 2% (imbalances upto 50% of the load)
Dynamic Recovery Time 3 cycles at 90 % of the static value
Admissible Overload 110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load Current Limit <1%
Current Limit High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit
Static Bypass
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
Maintenance Bypass
Type Without interruption
Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency
Line Mode 90.00% 91.00% 92.00%
Battery Mode 91.00% 92.00% 93.00%
Battery & Charger
Battery Type and Numbers 12VDC x 32 pcs (29-32 p. adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current *Default 10A; Maximum 40A; 5A@ full load
Charging Voltage 432 VDC (Based on 32pcs batteries)
Physical
Dimensions, D X W H(mm) 656x405x941 821x432x1159 975x554x1286 975x554x1326 1051x705x1646
Net weights (kgs) 193 278 365 471 573 650 760 840
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for RESQ GT 33 Online UPS System?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice