Listing ID #4488964
Company Information
Ask for more detail from the seller
Contact SupplierApplications :
Model | RES16KLB | RESQ2KLB | RESQ3KLB | RESQ6KLB | RESQ1OKLB | |
---|---|---|---|---|---|---|
Phase | Single phase with ground | |||||
Capacity | 1000 VA/800 W | 2000 VA/1600 W | 3000 VA/2400 W | 6000 VA/4800 W | 10000 VA/8000 W | |
Input | ||||||
Nominal Voltage | 200/208/220/230/240VAC | 208/220/230/24UVAC | ||||
Input Voltage Range | 110-300 VAC (Based on load at 50%) 160-280VAC (Based on load at 100%) | 110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%) | ||||
Frequency Range | 40Hz - 70 Hz | 46-54 Hz or 56-64 Hz | ||||
Power Factor | ≥0.99 @ Nominal Voltage (100% load) | |||||
Output | ||||||
Output Voltage | 200/208/220/230/240 VAC | 208/220/230/240 VAC | ||||
AC Voltage Regulation (Batt. Mode) | ±1% | |||||
Frequency Range (Synchronized Range) | 47~53Hz or 57-63Hz | 46~54Hz or 56-64Hz | ||||
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz | 50 Hz or 60 Hz ± 0.1 Hz | ||||
Crest Factor | 3:1 | |||||
Harmonic Distortion | ≤3 % THD (linear Load) , ≤6 % THD (Non-linear Load) | ≤3 % THD (linear Load) , ≤5 % THD (Non-linear Load) | ||||
Transfer Time | ||||||
AC Mode to Battery Mode | Zero | |||||
Inverter to Bypass | 4 ms (typical) | Zero | ||||
Waveform (Batt. Mode) | Pure Sinewave | |||||
Efficiency | ||||||
Overall Efficiency | > 90% | |||||
Battery | ||||||
Number of batteries | 3 | 6/8 | 16/20 | |||
Charging Current (max.) | 1A/2A/4A/6A (Adjustable) | 1A/2A/4A/6A (Adjustable), 6A is only available for 16 pcs. Batteries) | ||||
INDICATORS | ||||||
LCD Panel | Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | |||||
Alarm | ||||||
Battery Mode | Sounding every 4 seconds | |||||
Low Battery | Sounding every second | |||||
overload | Sounding twice every second | |||||
Fault | Continuously sounding | |||||
Physical | ||||||
Dimension, DXWXH (mm) | 282x145x220 | 397x145x220 | 369x190x318 | 442x190x318 | ||
Net Weight (kgs) | 4.1 | 6.8 | 7.4 | 12 | 16 | |
Environment | ||||||
Operation Humidity | 20-90 % RH 0- 40°C (non-condensing) | 0-95 % RH 0- 50°C (non-condensing) | 0-95 % RH 0- 40°C (non-condensing) | |||
Noise Level | Less than 58dBA @ 1 Meter | Less than55dBA @ 1 Meter | Less than 58dBA @ 1 Meter | |||
Management | ||||||
Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows. 7/8, Linux and MAC | |||||
Optional SNMP | Power management from SNMP manager and web browser | |||||
Standards | IP20, IEC62040-3, EN62040-1,2 COMPLIANCE : CE / ROHS |