Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Remote Monitoring System

Listing ID #149415

  • Supply Type Exporter, Supplier
  • Preferred Buyer Location All over the world

We are a prominent Supplier of technologically advanced Remote Monitoring System that is made from quality components thus ensure high durability. This Remote Monitoring System is used for the....
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Retailer
  • Year of Establishment 2010

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

We are a prominent Supplier of technologically advanced Remote Monitoring System that is made from quality components thus ensure high durability. This Remote Monitoring System is used for the transmission of video images at the receiver's end. Our range of Remote Monitoring Systems is widely demanded by the clients owing to its superior performance and easy installation.
Features :
Longer working lifeEasy maintenanceOptimum qualityHigh performance
Specifications
Overall System Specification1System Components Application server Communication Plug Voltage sensor modules Current sensor modules Temperature sensor modules Power Supply unit Management server deployment Globally on internetBattery Type Tubular Number of Current sensor per string Typically 1 Number of Ambient Tempe1 per Battery Bank Number of Voltage sensor 1 per battery (6 V nominal / unit)Number of Battery Box Temperature Sensor21 per BatteryNumber of BatterCommunication between server and Communication Plug encrypted confidentiality and data IntegrityUser and device (power plant) authenticationand AuthorizationReplay protectionSystem parameter Specification Parameters used to detect status of comInput Current from Wind GeneratoVoltage at Wind battery inDuration of above input Input Current from Solar Module Voltage at Solar Battery inDuration of above input Input Current from AC/DC charger Voltage at charger batteryDuration of above input Total Input Current to batteBattery VoltageDuration of above inputBattery parameters used to calculate the State of Charge (SOC) and State of Health (SOH) Battery Input CurrentBattery Output Current Battery unit voltage Battery Total Voltage Battery box temperature Battery on charge/ on discharge status Rate of change of Charge Rate of change of VoltageDepth of DischarCycle Count Estimated life of Battery used (evolved data)Past health of battery (evolved dataTimeAmbient Temperature Plug SpecificationsPower supply 230VAC or 48 V DC or 24 V DCPower dissipation 5 WInterface to sensor network RS232Interface to application server GPRS Voltage sensor SpecificationsPower Consumption from bus0.05 WPower Consumption from battery0.15 WMeasurement range 5 – 16 V Accuracy1.00% Operating Temperature0 – 55 CLED Indicator Indicating proper connection between Voltage between sensor module and battery leadsCurrent sensor SpecificationsPower Consumption0.1 WCurrent RangeMin (A)Max (A)05001000200Accuracy+ / - 2%Operationg Temperature0-55 COperating ModeNon InvasiveTure sensor SpecificationsTemperature Measurement Range0 to 70 deg CAccuracy+ / - 2%Protection Mechanism SpecificationsShort Circuit protection Fuse4 on Sense WireProtection from Open Cells in BatteryFuse5 on sense wireIsolation OptionalNoise on Battery leads due to LoadFiltersFailure of any sensorWill not affect other sensor modules1 Standard Configuration
2To identify thermal run-away conditions in VRLA batteries
3Not in Critical path
4Field replaceable glass case fuse
5Field replaceable glass case fuse
Wind - Solar - Battery Diesel Hybrid Power Plant Monitoring System
By logging into the website with his own password, the user can see :
Remote Monitoring SystemWind power generation at any instant.Wind power generation for past one hour, one day, one week, one month or one year.Solar power generation at that instant.Solar power generation for past one hour, one day, one week, one month or one year.Diesel Generator Power output at that instant (if it is running at that time).Number of hours of D.G. Operation & power generation data upto last one year.Charging or Discharging Current & Voltage of battery at that instant.Charging or Discharging Current & Voltage of battery upto last one yearor more.State of charge of battery (instantaneous & historic)State of health of battery or individual (12V/6V/2V) units.Cumulative number of cycles of charge & discharge undergone by battery.Battery – Percentage of life used up & life left.Power received/supplied by the power plant in one day, one week or one year.Any one or two emergency condition signal (as stated by user) can be sent to user in form of email or sms.


Company Details close-icon

We are southern india distributors of luminous renewable energy solutions (p) ltd . We supply solar water heaters , solar streetlighting & solar fencing also.
  • Nature of Business Exporter / Supplier / Retailer
  • Number of Employees Below 20
  • Year of Establishment 2010
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Remote Monitoring System?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice