    Multicolor Copper PVC Cables

    • MOQ50 Roll
    • MaterialPVC
    • Innner MaterialCopper, Aluminium
    • ColorMulticolor
    • TypeLow Voltage PVC Cables
    • Country of OriginIndia
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    location Kundli, Sonipat, Haryana
    View Number
    • calendar Member Since 20 Years
    • building Nature of Business Manufacturer
    • gst icon GST No. 06AAECR4146D1ZO

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • MaterialPVC
    • Innner MaterialCopper, Aluminium
    • ColorMulticolor
    • TypeLow Voltage PVC Cables
    • Country of OriginIndia

    Low Voltage PVC Cables
    We are positioned amongst the prominent Fire Resistant LV Pvc Wires Manufacture & supplier in India. The Low Voltage PVC Cables as well as PVC Insulated Cables that we provide are designed and manufacturers by the experts. All our PVC Cables conform to the requisite norms of the industry. Furthermore, PVC Insulated Cables are manufactured with Aluminum and Copper conductors confirming to IS 1554(Part-1)-1988 Indian Standards and to International Standards like BS, IEC, etc. Besides, our LV PVC Cables are approved by leading Electrical Consultants companies.
    Product Range

    • PVC insulated Heavy duty cables up to 1.1 kv.
    • PVC insulated Control Cables Up to 61 cores in Voltage grade 650/1100 V.
    • PVC insulated Mining Cable.
    • PVC insulated Flexible Cable.
    • PVC insulated electrical wiring Cable.


    Manufacturing Range

    • Aluminium and Copper Conductors
    • Single Core Cables up to 1000sqmm
    • Multi Core Cables up to 630 sqmm
    • Normal PVC or HR PVC Insulation
    • Special purpose FR/FRLS Sheath
    • Construction : Armoured, Unarmoured


    Construction Details
    Conductor

    • Conductors are made from Electrolytic grade aluminium / Copper as per Class 1 & 2 of IS: 8130:1984


    Insulation (IS: 5831-1984)

    • PVC Type A: General Purpose Insulation for Fixed Installation Cables.
    • PVC Type C: Heat Resisting (HR) Insulation.


    Core Identification
    The cores are identified by different colours as mentioned below:

    • Single-core: Red, Yellow, Blue, Black or any colour as per Customers requirement
    • Two-core: Red and Black
    • Three-core: Red, Yellow, and Blue
    • Three and half core : Red, Yellow, Blue, and reduced neutral core in Black.
    • Four-core : Red, Yellow, Blue, and Black
    • Five Core Cables: Red, Yellow, Blue, Black and Grey.
    • Six Core and above   : Two adjacent cores (counting & direction) in each layer Blue and Yellow,remaining cores Grey.The same sequence as mentioned above along with indelible printing of core numbers or All cores of same colour with indelible numbering on each core in contrasting colour. Other colour in agreement with the purchaser and the manufacturer with number coding.


    Laying Up
    Cores are laid up as per the above colour scheme with a suitable right hand lay.
    Inner Sheath
    Laid up cores are Provided by either wrapping or extrusion as agreed to between the supplier and the purchaser with thermoplastic material. The material used shall be compatible with the temperature rating of the LV Pvc cable.
    Armouring
    Armouring is provided over the inner sheath to guard against mechanical damage. Armouring is generally of galvanized steel wires or strips. Armouring shall be provided over the inner sheath with a suitable left hand lay.The minimum coverage of Armour shall be 90 % In single-core cables, used in the AC system, armouring is by non-magnetic hard drawn aluminium wires. Round steel wires are used where the diameter over the inner sheath does not exceed 13 mm, above 13 mm. flat steel strip armour is used. Round wire of different sizes can also be provided against specific requests.
    Outer PVC Jacket
    The Outer Sheath shall be applied over the Inner Sheath or over the laid-up cores. In case the Outer Sheath is provided over the laid-up cores then the Average thickness of Outer Sheath shall be the sum of the Nominal Thickness of Outer Sheath as specified in IS: 1554 (Part-1)-1988 and the Minimum thickness of Inner Sheath as specified in the standard.


    Armoured PVC Sheathed Control Cables


    Download Detail File : Click Here

    Armoured PVC Sheathed Control Cables-2


    Download Detail File : Click Here

    Armoured PVC Sheathed Four Core Cables


    Download Detail File : Click Here

    Armoured PVC Sheathed Single Core Cables


    Download Detail File : Click Here

    Armoured PVC Sheathed Three And Half Core Cables


    Download Detail File : Click Here

    Armoured PVC Sheathed Three Core Cables


    Download Detail File : Click Here

    Armoured PVC Sheathed Two Core Cables


    Download Detail File : Click Here
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for PVC Cables?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice