Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Pure Water Tester

Listing ID #4823480

4,600 / Piece
Get Latest Price
  • EC Accuracy±2% F.S.
  • Dimensions175 x 41 x 23 mm (6.9 x 1.6 x 0.9’’)
  • Battery Type/Life1.5V (4) / approximately 250 hours of continuous use
  • EC/TDS Temperature Compensationautomatic from 0 to 50°C (32 to 122°F) with β=2%/°C typical
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 5 Years
  • Nature of Business Retailer
  • GST No. 27AACCH2670Q1Z4

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • EC Accuracy ±2% F.S.
  • Ordering Information HI98308 is supplied with protective cap, calibration screwdriver (HI98308), batteries and instructio
  • EC Calibration manual, one point
  • Battery Type/Life 1.5V (4) / approximately 250 hours of continuous use
  • Dimensions 175 x 41 x 23 mm (6.9 x 1.6 x 0.9’’)
  • Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
  • Weight 95 g (3.4 oz.)
  • EC/TDS Temperature Compensation automatic from 0 to 50°C (32 to 122°F) with β=2%/°C typical
  • EC Range 0.0 to 99.9 µS/cm
  • EC Resolution 0.1 µS/cm

The HI98308 Pure Water tester is a rugged and reliable pocket-sized tester that offers quick and accurate readings. The HI98308 Pure Water tester features graphite electrodes to reduce polarization effects and an exposed temperature probe for fast response when compensating for temperature changes. Manual calibration is performed to a single point.

  • Exposed temperature sensor
  • Very low range EC - 0.0 to 99.9 μS/cm
  • Single point manual calibration


Details

  • The HI98308 features an amperometric graphite electrode that provides better repeatability in measurements since they do not oxidize. An amperometric measurement of EC is based on Ohm’s Law, I = V/R, where R depends on the distance between two pins and their surface. Oxidation changes both the distance and surface, which will affect accuracy. The non-oxidizing graphite pins are able to provide an optimal surface for accurate, dependable results. When calibration is needed, simply submerge the electrode tip into calibration solution and adjust the trimmer on the side of the tester.
  • The HI98308 uses a conductometric measurement to determine the purity of water. The HI98308 Pure Water Test (PWT) enables users to check the purity of distilled or demineralized water in laboratory or industrial environments. PWT is suited for fiŽelds such as printed circuit board washing, laundry, steam cleaning, checking car battery water and all areas where distilled, demineralized or pure water is used. This tester is housed in durable casing that provides excellent protection against harsh industrial environments.
  • Electrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges on atomic or larger sized particles in a medium are moved under the inŠfluence of a potential diff‹erence. EC is a measure of concentration, however, it is non-speci‡c for ion type. An ion is a charged particle present in the solution that contributes to the current Šflow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na+ and Cl-. This is a simplifi‡ed de‡finition as the measurement is a‹ffected by many things such as the type of ionic compound(s) dissolved in the water; the ions mobility, the solution viscosity, temperature as well as concentration.
  • Electrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. “Conductance” and “Resistance” depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are “normalized” terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specifi‡c measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna’s meters provide these measurements also.


Features at-a-glance:

  • One-point calibration - Calibrate with 84 µS/cm EC solution using a screwdriver
  • Exposed Temperature Probe - Fast response to changes in sample temperature
  • Automatic Temperature Compensation (ATC) - Samples automatically compensated for temperature variations
  • Graphite electrode - Reduced polarization effects


Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

Hanna

  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Pure Water Tester?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice