Contact SupplierThe pure steam generation system consists of two columns – Evaporator and Separator.
The Evaporator is a shell and tube type of heat exchanger. The driving force i.e. plant steam heats the feed water in the tube side of the evaporator to generate vapour. The generated vapour enters the Separator column. The separator column uses a triple punch separation technique for particle entrainment and separation of impurities such as droplets and pyrogenic material.
The first punch is offered by the multi- directional baffle, which makes the vapour traverse a torturous path. In the second stage, the steam passes through a cyclone type centrifugal separator. The final blow is delivered by a Demister pad to ensure pyrogen free, dry and saturated steam.
Features