Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

PORTABLE THERMOCOUPLE CALIBRATOR IT52.50

Listing ID #3790219

  • Display LCD; 3½ digits 0.5” high
  • Accuracy at 27°C ± 0.1% FSD ± 1 digit
  • Ambient temp. 10…50°C
  • Accuracy of ACJC at 27°C ± 1°C, additional error of ± 1°C per 10°C change
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Retailer
  • Year of Establishment 1959

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Resolution 10 µV in 0…20 mV range 100 µV in 0…200 mV range
  • Display range 0-19.99 mV DC 0-199.9 mV DC
  • Display LCD; 3½ digits 0.5” high
  • Power supply 9V Battery, Eveready No. 216 or its equivalent
  • Cold Junction Automatic, Ref.
  • Weight 0.9 kgs
  • Size 84(W) x 42(D) x 205(H)mm
  • Ambient temp. 10…50°C
  • Low Battery Indication Provided on LCD
  • Effect of Temperature ± 0.1% FSD per 10°C change
  • Accuracy of ACJC at 27°C ± 1°C, additional error of ± 1°C per 10°C change
  • Battery life 20 hrs of continuous use
  • Compensation (ACJC) temp. 0ºC
  • Accuracy at 27°C ± 0.1% FSD ± 1 digit

Description

Portable Thermocouple Calibrator, IT52.50 incorporates in a single instrument a high precision but low drift mV source, Automatic Cold Junction Compensator and an accurate 3½ digit LCD, mV read out. IT52.50 simulates as well as measures Thermocouple mVs accurately and is used for measuring the Thermocouple outputs and calibrating instruments like Transmitters, Indicators, Controllers, and Recorders etc. having Thermocouple input.

Since Automatic Cold Junction Compensation (Ref. Temp. 0°C) is built-in, IT52.50 takes care of the ambient/room temperature variation while measurement and during simulation.

0-20 mV & 0-200 mV DC ranges, with resolution of 10 µV & 100 µV respectively, are selected by Function-cum-Range Selector in both simulate & measure modes. J, K, R & S Thermocouple or mV Sensors are selected by Sensor Selector, enabling measurement & simulation of most Thermocouples used commonly in addition to mV for any other sensor. Precise & stepless adjustment of mVs is done by a ten turn “mV adjust Potentiometer” and read on digital display.

  • FEATURES
  • Dual function capability: Simulates and measures Thermocouple J, K, R & S and mVs
  • Battery operated and ideally suitable for testing Thermocouples and calibrating instruments in the field & in control room
  • High accuracy of ± 0.1% FS ± 1 digit
  • Large clear display, 3½ digits, LCD, 0.5” high
  • High resolution of 10 µV
  • Automatic Cold Junction Compensation
  • Portable, Rugged, Light weight and Handy
  • APPLICATIONS
  • Used for simulation & measurement of Thermocouple J, K, R & S and mVs accurately
  • Calibration of instruments like Transmitters, Indicators, Controllers, and Recorders etc in field & in control room having Thermocouple input

 


Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

We at Toshniwal Industries over the years have developed an unparalleled respect & admiration in the Industrial world based not just on the high quality of products that we supply but also the customer services.
We believe that in today's world Customer Service & On-Time Support is extremely important. To meet out the customer's requirement we have set up a strong team of engineers to study the Customer's Application, Design a Cost Effective Perfectly Engineered Solution with Drawings and then executing the order smoothly in the desired time followed by Training before handing over.
Along with this we also have an NABL Accredited Laboratory and offer Calibration for Electro-Technical and Thermal Parameters. We maintain traceability to National Physical Laboratory (NPL). With Calibration facilities we offer a one stop solution to the customer and ensure his process runs with accuracy !
We also have a team of Engineers to offer Thermography Services to our customers. We offer Trainings & do regular Seminars for our customers to understand new applications and trends in the Instrumentation World.
Toshniwal Industries Pvt Ltd. (TIPL), an ISO 9001:2008 certified company is a Private Limited company incorporated in 1959 at Mumbai. The company was set-up under the aegis of Toshniwal Brothers Pvt. Ltd. (Estb. 1948) under the guidance of its founding Chairman & Managing Director, (Late) Dr. G.R. Toshniwal, D. Sc. And thereafter his son Mr M.G. Toshniwal, B. Sc (Engg.). In a short span of time, TIPL was recognised as a leading instrumentation company in India as a manufacturer of quality instruments and excellent services to customers.
Manufacturing commenced in a spacious factory setup at Ajmer in 1963 in technical collaboration with world leading instrumentation companies like Hartmann & Braun, Germany; British Electric Co. Ltd., UK; W.G. Pye & Co., UK. After completion of the term of these collaboration agreements, TIPL continues to manufacture instruments as per the technical know-how received. Many of the instruments, as per the collaborator’s designs, have been up-dated with the efforts of their in-house R&D. Since 1984, TIPL has taken up the marketing of various related product lines from renowned manufacturers from Japan, USA, UK & Germany and provide complete application engineering, installation & commissioning and after sales service support to customers.
Mrs. Manju Toshniwal, Chairman and Mr. Rajeev Toshniwal, Managing Director of TIPL have a long experience of managing medium size engineering industry and are supported by a team of professionals. TIPL owes its technological leadership to its engineers and business managers backed by a dedicated work force.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 100 - 150
  • Year of Establishment 1959
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for PORTABLE THERMOCOUPLE CALIBRATOR IT52.50?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
PORTABLE THERMOCOUPLE CALIBRATOR IT52.50 at Best Price in Ajmer - ID: 3790219
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

PORTABLE THERMOCOUPLE CALIBRATOR IT52.50

Listing ID #3790219

  • Low Battery Indication Provided on LCD
  • Resolution 10 µV in 0…20 mV range 100 µV in 0…200 mV range
  • Accuracy at 27°C ± 0.1% FSD ± 1 digit
  • Display LCD; 3½ digits 0.5” high
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Retailer
  • Year of Establishment 1959

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Ambient temp. 10…50°C
  • Display LCD; 3½ digits 0.5” high
  • Resolution 10 µV in 0…20 mV range 100 µV in 0…200 mV range
  • Cold Junction Automatic, Ref.
  • Weight 0.9 kgs
  • Compensation (ACJC) temp. 0ºC
  • Size 84(W) x 42(D) x 205(H)mm
  • Battery life 20 hrs of continuous use
  • Accuracy at 27°C ± 0.1% FSD ± 1 digit
  • Low Battery Indication Provided on LCD
  • Power supply 9V Battery, Eveready No. 216 or its equivalent
  • Display range 0-19.99 mV DC 0-199.9 mV DC
  • Effect of Temperature ± 0.1% FSD per 10°C change
  • Accuracy of ACJC at 27°C ± 1°C, additional error of ± 1°C per 10°C change

Description

Portable Thermocouple Calibrator, IT52.50 incorporates in a single instrument a high precision but low drift mV source, Automatic Cold Junction Compensator and an accurate 3½ digit LCD, mV read out. IT52.50 simulates as well as measures Thermocouple mVs accurately and is used for measuring the Thermocouple outputs and calibrating instruments like Transmitters, Indicators, Controllers, and Recorders etc. having Thermocouple input.

Since Automatic Cold Junction Compensation (Ref. Temp. 0°C) is built-in, IT52.50 takes care of the ambient/room temperature variation while measurement and during simulation.

0-20 mV & 0-200 mV DC ranges, with resolution of 10 µV & 100 µV respectively, are selected by Function-cum-Range Selector in both simulate & measure modes. J, K, R & S Thermocouple or mV Sensors are selected by Sensor Selector, enabling measurement & simulation of most Thermocouples used commonly in addition to mV for any other sensor. Precise & stepless adjustment of mVs is done by a ten turn “mV adjust Potentiometer” and read on digital display.

  • FEATURES
  • Dual function capability: Simulates and measures Thermocouple J, K, R & S and mVs
  • Battery operated and ideally suitable for testing Thermocouples and calibrating instruments in the field & in control room
  • High accuracy of ± 0.1% FS ± 1 digit
  • Large clear display, 3½ digits, LCD, 0.5” high
  • High resolution of 10 µV
  • Automatic Cold Junction Compensation
  • Portable, Rugged, Light weight and Handy
  • APPLICATIONS
  • Used for simulation & measurement of Thermocouple J, K, R & S and mVs accurately
  • Calibration of instruments like Transmitters, Indicators, Controllers, and Recorders etc in field & in control room having Thermocouple input

 


Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

We at Toshniwal Industries over the years have developed an unparalleled respect & admiration in the Industrial world based not just on the high quality of products that we supply but also the customer services.
We believe that in today's world Customer Service & On-Time Support is extremely important. To meet out the customer's requirement we have set up a strong team of engineers to study the Customer's Application, Design a Cost Effective Perfectly Engineered Solution with Drawings and then executing the order smoothly in the desired time followed by Training before handing over.
Along with this we also have an NABL Accredited Laboratory and offer Calibration for Electro-Technical and Thermal Parameters. We maintain traceability to National Physical Laboratory (NPL). With Calibration facilities we offer a one stop solution to the customer and ensure his process runs with accuracy !
We also have a team of Engineers to offer Thermography Services to our customers. We offer Trainings & do regular Seminars for our customers to understand new applications and trends in the Instrumentation World.
Toshniwal Industries Pvt Ltd. (TIPL), an ISO 9001:2008 certified company is a Private Limited company incorporated in 1959 at Mumbai. The company was set-up under the aegis of Toshniwal Brothers Pvt. Ltd. (Estb. 1948) under the guidance of its founding Chairman & Managing Director, (Late) Dr. G.R. Toshniwal, D. Sc. And thereafter his son Mr M.G. Toshniwal, B. Sc (Engg.). In a short span of time, TIPL was recognised as a leading instrumentation company in India as a manufacturer of quality instruments and excellent services to customers.
Manufacturing commenced in a spacious factory setup at Ajmer in 1963 in technical collaboration with world leading instrumentation companies like Hartmann & Braun, Germany; British Electric Co. Ltd., UK; W.G. Pye & Co., UK. After completion of the term of these collaboration agreements, TIPL continues to manufacture instruments as per the technical know-how received. Many of the instruments, as per the collaborator’s designs, have been up-dated with the efforts of their in-house R&D. Since 1984, TIPL has taken up the marketing of various related product lines from renowned manufacturers from Japan, USA, UK & Germany and provide complete application engineering, installation & commissioning and after sales service support to customers.
Mrs. Manju Toshniwal, Chairman and Mr. Rajeev Toshniwal, Managing Director of TIPL have a long experience of managing medium size engineering industry and are supported by a team of professionals. TIPL owes its technological leadership to its engineers and business managers backed by a dedicated work force.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 100 - 150
  • Year of Establishment 1959
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for PORTABLE THERMOCOUPLE CALIBRATOR IT52.50?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice