Company Information
Ask for more detail from the seller
Contact SupplierFeatures
Type Explanation
Model | NV-100C | NV-100H | NV-100D | NV-100S |
---|---|---|---|---|
Detection Principle | Catalytic combustion | Hot-Wire Semiconductor | Controlled Potential Electrolysis | Galvanic Cell |
Gas Detected | Combustible gas ( L.PG, Methane, .etc.) | Combustible gas ( L.PG, Methane, .etc.) | Toxic gas/ Semiconductor manufacturing gas | Oxygen (deficiency/leakage) |
Detection Range | 0-100%LEL | As per specification | As per specification | 0-25vol% (deficiency) 0-50vol% (leakage) |
Concentration Indicator | LCD bar-graph meter with backlight | LCD bar-graph meter with backlight | LCD bar-graph meter with backlight | LCD bar-graph meter with backlight |
Alarm Accuracy | ±25% of an alarm set value | ±25% of an alarm set value | ±30% of an alarm set value | ±1.0vol% of an alarm set value (conferms to JIS T 8201) |
Operating Temperature Range | 0oC to 40oC | 0oC to 40oC | 0oC to 40oC | 0oC to 40oC |
Power Source/Power Consumption | 100-240V AC, 50/60Hz (standard), 24V DC (option); Diffusion type: 12VA/17VA (with the backup power source), Suction type: 4VA per unit to be added | 100-240V AC, 50/60Hz (standard), 24V DC (option); Diffusion type: 12VA/17VA (with the backup power source), Suction type: 4VA per unit to be added | 100-240V AC, 50/60Hz (standard), 24V DC (option); Diffusion type: 12VA/17VA (with the backup power source), Suction type: 4VA per unit to be added | 100-240V AC, 50/60Hz (standard), 24V DC (option); Diffusion type: 12VA/17VA (with the backup power source), Suction type: 4VA per unit to be added |
Alarm Indication | Ist stage: Red lamp for Ist stage alarm flashing, 2nd stage: Red lamps for Ist and 2nd stage alarms flashing | Ist stage: Red lamp for Ist stage alarm flashing, 2nd stage: Red lamps for Ist and 2nd stage alarms flashing | Ist stage: Red lamp for Ist stage alarm flashing, 2nd stage: Red lamps for Ist and 2nd stage alarms flashing | Ist stage: Red lamp for Ist stage alarm flashing, 2nd stage: Red lamps for Ist and 2nd stage alarms flashing |
Trouble Indication | Power source lamp lights up in orange | Power source lamp lights up in orange | Power source lamp lights up in orange | Power source lamp lights up in orange |
External Output | Alarm output terminal - 1st alarm (1c no-voltage contact), 2nd alarm (1c no-voltage contact,. Trouble alarm (1c no-voltage contact). Buzzer(1a no-voltage contact); Analog oulput : 4- 20mA; Contact capacity: 2A@100V AC (resistance load) | Alarm output terminal - 1st alarm (1c no-voltage contact), 2nd alarm (1c no-voltage contact,. Trouble alarm (1c no-voltage contact). Buzzer(1a no-voltage contact); Analog oulput : 4- 20mA; Contact capacity: 2A@100V AC (resistance load) | Alarm output terminal - 1st alarm (1c no-voltage contact), 2nd alarm (1c no-voltage contact,. Trouble alarm (1c no-voltage contact). Buzzer(1a no-voltage contact); Analog oulput : 4- 20mA; Contact capacity: 2A@100V AC (resistance load) | Alarm output terminal - 1st alarm (1c no-voltage contact), 2nd alarm (1c no-voltage contact,. Trouble alarm (1c no-voltage contact). Buzzer(1a no-voltage contact); Analog oulput : 4- 20mA; Contact capacity: 2A@100V AC (resistance load) |
Dimensions | Without backup power source : W 113.x H2O4 x D71.5mm, approx. 1.5kg With backup power source : W113xH234xD110mm, Approx. 3kg | Without backup power source : W 113.x H2O4 x D71.5mm, approx. 1.5kg With backup power source : W113xH234xD110mm, Approx. 3kg | Without backup power source : W 113.x H2O4 x D71.5mm, approx. 1.5kg With backup power source : W113xH234xD110mm, Approx. 3kg | Without backup power source : W 113.x H2O4 x D71.5mm, approx. 1.5kg With backup power source : W113xH234xD110mm, Approx. 3kg |