Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Plastic Earth Leakage Circuit Breaker

    • MaterialPlastic
    • Warranty1 Year
    • Rated Voltage230V
    • No. of Poles2
    • Supply TypeManufacturer, Supplier
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 10 Years
    • building Nature of Business Manufacturer
    • Year of Establishment 1996

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • MaterialPlastic
    • Warranty1 Year
    • No. of Poles2
    • Rated Current6-100a
    • Rated Voltage230V
    • Automation GradeAutomatic

    Our company is a well known Manufacturer and Supplier of Earth Leakage Circuit Breaker [ELCB] from Ahmedabad, Gujarat. These breakers are highly sensitive and can easily detect current leakage before it becomes a big risk. Customers can be assured of receiving a quality Earth Leakage Circuit Breaker  [ ELCB ] from us that conforms to BS standard 4293: 1983.
    Highlights :

    • A high sensitive current operated Earth Leakage Circuit Breaker  [ ELCB ]
    • Specially designed to give protection by disconnecting the power supply against risk of dangerous & possible lethal electric shocks
    • Detects dangerous leakage current exceeding the generally accepted safe limit of 30mA & isolates the effected section of installation
    • Confirms to BS standard 4293: 1983
    • Highly sensitive and high speed response unit
    • Sensitivity-based on rated tripping level from 3mA to 30mA
    • Response speed-Within 30m sec. of leakage exceeding set limits


    How It Operates?
    ACTIVE High sensitive current operated  Earth Leakage Circuit Breaker  [ ELCB ] incorporates an active current transformer, to sense the sum of all current to be normally zero. Normally current flowing through phase passes through the neutral through load so resultant voltage in an active transformer is zero. In case of any leakage to earth, core balance transformer senses as unbalance & small signal voltage is generated in secondary winding which is fed to solid state electronic circuit of ELCB. This is amplified and immediately activates the tripping mechanism of the unit. Hence, resulting in switching off and isolating the defective installation. This highly sophisticated Earth Leakage Circuit Breaker system (ELCB), based on the latest & ultimate in electronics design; is specifically engineered to protect you from dangerous electric shock and your equipment from High Voltage, Low Voltage, Overload and Short circuit. There are LED indications provided on the front panel display which informs you that your ELCB has sensed Fault and display its Fault status with LED indication along with Emergency Light and Audible Emergency Signal - Siren. After fault recovery, control circuit having inbuilt time delay will be activated within 5 seconds instantly and ELCB will be ON automatically-Fully Automatic (self start).


    PROTECTIONS

    MODEE/L = EARTH LEAKAGEO/L = OVERLOADH/V = HIGH VOLT.
    L /V =  LOW VOLT.
    WORKINGAvailableAvailableAvailable
    BYPASS(1)×AvailableAvailable
    BYPASS(2)×××

    RATINGS

    PARAMETERS
    Particulars1-phase3-phase
    Rated  Voltage230±10% Volt A.C. 50Hz.415±10% Volt A.C. 50Hz.
    Rated  Load Current0-32  Amp (Adjustable)0-32  Amp (Adjustable)

    EXCLUSIVE HIGH PERFORMANCE FEATURES

    Protection1Earth Leakage Current3 - 30mAmp. (Adjustable)For Shock Protection
    2Overload  0 - 32 Amp Overload set.For equipment Safety
    3Short  circuitInbuilt  Overload functionFor  total premises Safety
    4High Voltage Cut-off / Cut-inAbove  305 Volt. A.C./ Below  290 Volt. A.C.For equipment Safety
    5Low Voltage Cut-Off / Cut-inBelow  160 Volt A.C. ./ Above  180 Volt. A.C.For equipment Safety
    6

    By Pass  Function (1)

    By Pass  Function (2)

    As per chart on  ELCB enclosure - metal bodySemi Bypass = Bypass (1)
    Fully Bypass = Bypass(2)
    Facilities7Emergency indicationEmergency Light Facility     For light up the area.
    8Emergency  Audible SignalSiren FacilityIt informs that there is a fault in system.
    9Fully Automatic - Self StartWithin 5 second

    Auto Reset

     

    10Fault  IndicationLED DisplayOn  front  panel display
    11Tripping Time Less than 30mSec.  High speed  Responses
    12Highly sophisticated Control Circuit operated Relay mechanismHigh precision availableFor instant tripping & isolates the defective installation
    13TEST  FunctionPush the button  ‘ TEST ’ to check the healthy function of ELCBTo confirm the Earth leakage test

    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Earth Leakage Circuit Breaker?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice