Contact SupplierOur company is a well known Manufacturer and Supplier of Earth Leakage Circuit Breaker [ELCB] from Ahmedabad, Gujarat. These breakers are highly sensitive and can easily detect current leakage before it becomes a big risk. Customers can be assured of receiving a quality Earth Leakage Circuit Breaker [ ELCB ] from us that conforms to BS standard 4293: 1983.
Highlights :
How It Operates?
ACTIVE High sensitive current operated Earth Leakage Circuit Breaker [ ELCB ] incorporates an active current transformer, to sense the sum of all current to be normally zero. Normally current flowing through phase passes through the neutral through load so resultant voltage in an active transformer is zero. In case of any leakage to earth, core balance transformer senses as unbalance & small signal voltage is generated in secondary winding which is fed to solid state electronic circuit of ELCB. This is amplified and immediately activates the tripping mechanism of the unit. Hence, resulting in switching off and isolating the defective installation. This highly sophisticated Earth Leakage Circuit Breaker system (ELCB), based on the latest & ultimate in electronics design; is specifically engineered to protect you from dangerous electric shock and your equipment from High Voltage, Low Voltage, Overload and Short circuit. There are LED indications provided on the front panel display which informs you that your ELCB has sensed Fault and display its Fault status with LED indication along with Emergency Light and Audible Emergency Signal - Siren. After fault recovery, control circuit having inbuilt time delay will be activated within 5 seconds instantly and ELCB will be ON automatically-Fully Automatic (self start).
MODE | E/L = EARTH LEAKAGE | O/L = OVERLOAD | H/V = HIGH VOLT. L /V = LOW VOLT. |
---|---|---|---|
WORKING | Available | Available | Available |
BYPASS(1) | × | Available | Available |
BYPASS(2) | × | × | × |
PARAMETERS | ||
Particulars | 1-phase | 3-phase |
Rated Voltage | 230±10% Volt A.C. 50Hz. | 415±10% Volt A.C. 50Hz. |
Rated Load Current | 0-32 Amp (Adjustable) | 0-32 Amp (Adjustable) |
Protection | 1 | Earth Leakage Current | 3 - 30mAmp. (Adjustable) | For Shock Protection |
---|---|---|---|---|
2 | Overload | 0 - 32 Amp Overload set. | For equipment Safety | |
3 | Short circuit | Inbuilt Overload function | For total premises Safety | |
4 | High Voltage Cut-off / Cut-in | Above 305 Volt. A.C./ Below 290 Volt. A.C. | For equipment Safety | |
5 | Low Voltage Cut-Off / Cut-in | Below 160 Volt A.C. ./ Above 180 Volt. A.C. | For equipment Safety | |
6 | By Pass Function (1) By Pass Function (2) | As per chart on ELCB enclosure - metal body | Semi Bypass = Bypass (1) Fully Bypass = Bypass(2) | |
Facilities | 7 | Emergency indication | Emergency Light Facility | For light up the area. |
8 | Emergency Audible Signal | Siren Facility | It informs that there is a fault in system. | |
9 | Fully Automatic - Self Start | Within 5 second | Auto Reset
| |
10 | Fault Indication | LED Display | On front panel display | |
11 | Tripping Time | Less than 30mSec. | High speed Responses | |
12 | Highly sophisticated Control Circuit operated Relay mechanism | High precision available | For instant tripping & isolates the defective installation | |
13 | TEST Function | Push the button ‘ TEST ’ to check the healthy function of ELCB | To confirm the Earth leakage test |