Contact SupplierThese systems are used for the production of ingots from 1-2 kg, both in manual mode so that "full automatic", including robotization for weighing operations and crucibles loading, etc. slingottamento operations.
The induction furnaces ITALIMPIANTI ORAFI are all equipped with static converters frequenza.Il frequency conversion system used has enabled the achievement of high electrical efficiency, such as to significantly reduce the consumption of electricity equal to 'the production performed.
The modular construction of the electrical circuit greatly simplifies the maintenance operations and ensures high reliability 'even in the most demanding operating conditions.
The high technical level achieved in the design of the inductors, coupled to a construction technique which is also modular and the use of high quality materials', the maximum guarantee of production even in the harshest conditions.
TECHNICAL FEATURES OVEN:
The ovens consist of two, three, six or more special crucibles to melt 1 kg of gold each. Each crucible has its own burner to protect the metal from oxidation during melting. After the fusion, with a pedal or button system, the crucible is lifted from its seat by means of pliers and the metal is manually poured into ingot molds.
FREQUENCY CONVERTER STATIC:
UNITS 'CONTROL SOLIDIFICATION INGOTS
This unit is composed of:
TECHNICAL DATA | FIM12 / LING | FIM15 / LING | FIM45 / LING |
Supply | Three Phase | Three Phase | Three Phase |
Absorbed power | 12 kW | 15 kW | 45 kW |
Yield Power | 11.4 kW | ||
Flow Water Cooling (liters / min) | 20 | 23 | 30 |
Minimum Pressure Water Cooling | 2 Bar | 2 Bar | 3 Bar |
Temperature Water Cooling | 30 ÷ 35 °C | 30 ÷ 35 °C | 30 ÷ 35 °C |
Refrigerant Power Required | 10500 Kcal/h | 25000 Kcal/h | |
Hourly production | 15 Ingots / Time | 20 Ingots / Time | 40 Ingots / Time |
TECHNICAL DATA | FIM50 / LING | FIM60 / LING | FIM80 / LING | FIM100 / LING |
Supply | Three Phase | Three Phase | Three Phase | Three Phase |
Absorbed power | 50 kW | 60 kW | 90 kW | 100 kW |
Yield Power | ||||
Flow Water Cooling (liters / min) | 30 | 30 | 30 | 30 |
Minimum Pressure Water Cooling | 3 Bar | 3 Bar | 3 Bar | 3 Bar |
Temperature Water Cooling | 30 ÷ 35 °C | 30 ÷ 35 °C | 30 ÷ 35 °C | 30 ÷ 35 °C |
Refrigerant Power Required | 25000 Kcal/h | 52000 Kcal/h | 52000 Kcal/h | 52000 Kcal/h |
Hourly production | 50 Ingots / Time | 60 Ingots / Time | 80 Ingots / Time | 100 Ingots / Time |