Listing ID #3923797
Company Information
Ask for more detail from the seller
Contact SupplierMain Technical Parameters:
Detection matrix (multi-matrix): sample analysis of Fe, Al, Cu, Ni, Co, Mg, Ti, Zn, Pb, Sn, Ag and other metals and their alloys
Analysis channel (multi-channel): 45 channels
Analysis wave band (wide range): 160nm ~ 650nm
Detection time (short): according to different sample types, generally less than 30 seconds
Optical room (fine constant-temperature): 38 °C ± 0.2 °C
Power supply: single-phase power with protection grounding. Voltage: 220VAC, Frequency: 50Hz, Service power: 1.8KVA
Environmental conditions: operating temperature: 10-30 °C, Storage Temperature: 0-45 °C, Humidity: ≤ 85%
Features:
1.750 mm focal length grating, Pa-based - Runge devices, high vacuum, high resolution and high sensitivity;
2.Its electronic system adopts cage of international standard, high integrated circuit design with low failure rate;
3.The excitation source frequency can be adjusted between 150/600Hz, different excitation parameters can be chosen based on different samples to achieve the best results;
4.Solid auxiliary electrode of excitation light source to avoid jamming and improve the stability of the excitation light source, adjusting-free;
5.In the process of exciting samples, it is unnecessary for water cooling on the station and it can conduct continuous analysis;
6.Multi-element automatic tracing, can quickly analyze the deviation of each element to base one;
7.Automatic adjusting of computers to negative pressure of 8 channels, which greatly improves channel utilization and the application of the best linear range of analysis spectral lines and reduces the number of channels used in the process so as to cut the cost.
8.Overall constant-temperature ensures normal operation of the instrument, and reduces demands on the environment.
9.Using high-precision linear motor for slit scanning with high speed and high accuracy;
10.Made of aluminum alloy and with vacuum chamber;
11.Anti-seismic design of spectroscopy room, for instance, using dynamic installation for optical components such as grating and slit to achieve high stability;
12.Built-in light in spectroscopy room to improve the stability of photomultiplier, eliminate dead time, promote noise ratio and extend its service life.
13.With software systems of different languages to .meet the requirements of different countries.
14.Database system is set of the computer software, which facilitates the data query and print of measurement data, and enables data transmission through remote network, convenient and quick.