Company Information
Ask for more detail from the seller
Contact SupplierBasic unit has the following protocol converters:rs-232 to rs-485 converterinput: rs-232 protocoloutput: rs-485 protocolself tuner insidespeed : 300115.200 bps256 modules in one rs-485 network without repeater3000v isolationmultiple baud rate, multiple data formatcommunication distance:- 2.1km/9600 bps- 2.7km/4800 bps- 3.6km/2400 bpsrs-232 to rs-422/485 converterinput : rs-232 protocoloutput : rs-422/485 protocolself tuner insidespeed : 300115.200 bps256 modules in one rs-485 network without repeater3000v isolationmultiple baud rate, multiple data formatcommunication distance:- 2.1km/9600 bps- 2.7km/4800 bps- 3.6km/2400 bps8-channel analog input moduleanalog input type : mv, v or mainput range: +/-15mv, +/-50mv, +/-100, +/-500mv, +/-1v, +/- 2.5v, +/-20machannels : 6 differential, 2 single-ended or 8 differential (jumper selectable)sampling rate : 10 samples/sec8-channel thermocouple input moduleanalog input type : thermocouple, mv, v or mainput range : +/-15mv, +/-50mv, +/-100, +/-500mv, +/-1v, +/- 2.5v, +/-20mathermocouple type : j, k, t, e, r, s, b, n, csampling rate : 10 samples/secprogrammable hi/low alarmchannels : 6 differential, 2 single-ended or 8 differential (jumper selectable)gui based windows compatible softwareoriginal licensed version with hardware lockuser can do required analysis with the use of following modulesinput- analog input- digital input- rs-232 input etc.display- x/y chart- x/t chart- chart recorder- digital meter- bar graph- list displayfiles- read data- write data- back-up data- retrieve dataa/i multi-speeddata can be stored in various file formats for further analysis:-- ms excel format- graphical format- list format- text format etc.optional experimental modulesthese modules can be attached or detached as per users requirement.lift controlexperimental model of lift which is truly operational, totally controlled by manual switches to select the floors, set the priority through the program logics.water tank level control & reaction vesselsensors to detect different levels of water and switch off the water supply (logic controlled). This module is provided along with the water tank and sensors, required accessories control the temperature of water set by the thermostat at a particular temperature by the user.fan control simulatorcontrols the speed of fan at various steps. This module should be provided along with smps fan as an experimental model and switch to be provided to change the speed of the fan.sequential switching of motorssequential switching of motors with two nos. Of 220v ac/5a output to connect motor (motor not provided)seven segment displaysimulator for displaying a message.pick & place controlusing electromagnetic relays to control the displacement and energization of electromagnet to pick a small object and place it at the destination as per the logics made.