Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Oil Separators

Listing ID #4309016

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

Accumulator mainly in fixed orifice or capillary systems as there's no metering of liquid by demand (unlike TX valve systems that feed by demand), so the accumulator prevents liquid over flooding to....
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Accumulator mainly in fixed orifice or capillary systems as there's no metering of liquid by demand (unlike TX valve systems that feed by demand), so the accumulator prevents liquid over flooding to the compressor. Also sometimes fitted on TXV low temp applications like freezers, to prevent floodback of liquid to the compressor.

 

Oil separators used when system design could cause poor oil return, eg compressor above the evap, or uneven oil return in the case of multiple compressors. Cheap insurance and costs less than heaps of pipework modifications

 

Receiver necessary for TX valve systems, all that refrigerant not being used because the TXV is closing due to low load, has to go somewhere.

 

oil separator required in the following applications
a) flooded chiller 
b) use of non-miscible refrigerant like ammonia application
c) all applications below evaporator temp (-20) deg C 
d) air-conditining systems where MOP valve is not used ; since non-MOP valves open fully during start up due to warm suction line & time required for the TEX valve to come to equilibrium .



Company Details close-icon

Kirti Engineering had been established in Ahmadabad in 1972.We are master of our fields as such we have huge experience of this particular field. Our Organization is on success path due the great guidance and leadership of our owner Mr.Kanubhai Patel and Mr. Mitulbhai Patel.
We are one of the leaders as far as dealership of refrigeration control & Industrial switches are concern. We are also dealing in thermostatic expansion valves. At the same time we are dealing in refrigerant gas as well as hermetically sealed compressors for refrigerator, Air-condition, Water cooler, Vertical type medical freezer, Chilling plants.
We are also dealing with complete units of window & split air condition water coller, wisi coller and medical services. We also provide all types of pressure & temperature gauges and digital thermometers. We are also providing copper pipe, copper capillary, copper fittings & compressor brass fittings.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Oil Separators?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Oil Separators at Best Price in Ahmedabad - ID: 4309016 | Kirti Engineering
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Oil Separators

Listing ID #4309016

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

Accumulator mainly in fixed orifice or capillary systems as there's no metering of liquid by demand (unlike TX valve systems that feed by demand), so the accumulator prevents liquid over flooding to....
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Accumulator mainly in fixed orifice or capillary systems as there's no metering of liquid by demand (unlike TX valve systems that feed by demand), so the accumulator prevents liquid over flooding to the compressor. Also sometimes fitted on TXV low temp applications like freezers, to prevent floodback of liquid to the compressor.

 

Oil separators used when system design could cause poor oil return, eg compressor above the evap, or uneven oil return in the case of multiple compressors. Cheap insurance and costs less than heaps of pipework modifications

 

Receiver necessary for TX valve systems, all that refrigerant not being used because the TXV is closing due to low load, has to go somewhere.

 

oil separator required in the following applications
a) flooded chiller 
b) use of non-miscible refrigerant like ammonia application
c) all applications below evaporator temp (-20) deg C 
d) air-conditining systems where MOP valve is not used ; since non-MOP valves open fully during start up due to warm suction line & time required for the TEX valve to come to equilibrium .



Company Details close-icon

Kirti Engineering had been established in Ahmadabad in 1972.We are master of our fields as such we have huge experience of this particular field. Our Organization is on success path due the great guidance and leadership of our owner Mr.Kanubhai Patel and Mr. Mitulbhai Patel.
We are one of the leaders as far as dealership of refrigeration control & Industrial switches are concern. We are also dealing in thermostatic expansion valves. At the same time we are dealing in refrigerant gas as well as hermetically sealed compressors for refrigerator, Air-condition, Water cooler, Vertical type medical freezer, Chilling plants.
We are also dealing with complete units of window & split air condition water coller, wisi coller and medical services. We also provide all types of pressure & temperature gauges and digital thermometers. We are also providing copper pipe, copper capillary, copper fittings & compressor brass fittings.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Oil Separators?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice