    Multipara Monitor (FL-505)

    • Suitable ForPediatric, Neonatal, Infant, Adult
    • Accuracy±3bpm
    • Alarm accuracy:+-2 bpm
    • Lead Mode5 Leads ( R
    • Supply TypeManufacturer, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 15 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Product Details no_img_icon

    • Accuracy±3bpm
    • Suitable ForPediatric, Neonatal, Infant, Adult
    • DisplayLCD
    • Lead Mode5 Leads ( R
    • MeasurementsHeart Rate monitoring
    • Alarm accuracy:+-2 bpm

    Multipara Monitor (FL-505) that we offer is appreciated for its accurate result display. Our Multipara Monitor (FL-505) features 12"1 color TFT display along with large fonts for easy readability. Multipara Monitor (FL-505) shows maximum 96-hour graphic and tabular trends of all parameters. It also features newest anti-electric and anti-defibrillation designing. Our Multipara Monitor (FL-505) can be easily used in all kinds of adverse environments.
    Features

    • 12" 1 color TFT display and tabular trends of all parameters
    • ST segment analysis
    • Large font display
    • dynamic and short trend
    • All leads ECG waveforms display in phase
    • Newest anti-electric, anti-defibrillation designing
    • Can be used in all kinds of bad environment


    Specifications

    Power Requirements Alarm range15-350bpm
    AC 100-240 (AC), 50/60 HzS-T segment detectionMeasurement range : 2.0 mV – 2.0mV
    Power70VA Alarm range : 2.0mV – 2.0mV
    Temperature0-40 oCRespiration 
    Humidity15-95% non-CondensingMethodThoraci impedance
    Patient RangeAdults, Pediatric, neonateMeasurement rangeAdult0-120BrPm;
       Neonate/Pediatric 0 -150BrPM
    Performance Specifications Apnea AlarmYes
    Display12"1 Color TFTAlarmYes audible and visual alarm
    Resolution : 800x480NIBP 
    Multi displays selectable, includingMethodAutomatic oscillometric
    Standard displayOperation modesManual/Automatic/continuous
    Large-font DisplayAuto measure timeAdjustable
    Trend coexist displayMeasurement unitMmHg/kPa selectable
    OxyCRG dynamic view displayMeasurement typesSystolic, diastolic, mean
    IndicatorAlarm indicator lightRange of systolic pressureAdult mode : 40-270mm hg
    Power indicator light Pediatric mode : 40-200mm hg
    Battery indicator light Neonate mode : 40-135 mmHg
    QRS beep and alarm soundRange of diastorlic pressureAdult mode : 10-210mm Hg
    InterfaceAC Power input socket Pediatric mode : 10-150mm Hg
    Network interface Neonate mode : 10-100 mm Hg
    BatteryRechargeable lead-acid batteryRange of mean pressureAdult mode : 20-23mm hg
    (for 1 piece) maximum 12 hours for charging Pediatric mode : 20-165mm Hg
    2 Hours for continuous working Neonate mode : 20-110mm hg
    Trend time1-96 hoursAccuracy of blood pressureThe mean error shall be less than 5mm hg
    AlarmUser-adjustable high and low limits 2-levelMeasurementThe standard deviation shall be less than 8mm Hg
    Audible and visual alarmOver-pressure protectionDouble safety protection
    NetworkingConnected to central monitoring systemResolution1mm Hg
    RecorderBuilt-in, thermal arrayAlarmSystolic, diastolic, mean
    Waveform : 3 channelsPR form NIBPMeasurement 40-240bpm
    Paper width : 50mm Resolution 1bpm
    Printspeed : 25mm/s Accuracy + 3bpm or + 3% whichever is greater
    ECG SpO2 
    Lead type5-lead and 3-lead selectableMeasurement range0-100%
    Lead selection5-lead I ; II ; II; avR: avL; avF;VResolution1.00%
    3-lead; I:II;IIIAccuracy+2% (70-100%adult/pediatric, non-motion)
    ECG waveform2 channels +3% (70-100%, Neonate, non-motion);
    Gain selectionX 0.25x0.5;x1;x2; auto 0-69% unspecified
    Sweep speed12.5 mm/s, 25mm/s, 50mm/sAlarm range1-100%
    Heart rate rangeAdult 15-200bpmPulse rateRange 20-24 bpm
    neonate/pediatric : 15-350bpm Resolution : 1bpm
    Accuracy+1% or + 1bpm, whichever is greater Accuracy : +3 (non-motion)
    Resolution+1bpm Alarm renge : 20-254bpm
    FilterDiagnostic mode : 0.05-100hzTemperature 
    Monitoring mode : 0.5-40hzMeasurement range0-50oC (32-122oF)
    Surgical mode : 1-20hzResolution0.1 oC
    ProtectionWithstand 4000VAC/50Hz voltage in isolationAccuracy+0.1oC (excluding the sensor)
    Sacling signal1mV + 5%ChannelDual-channel, provide T1;T2
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Multipara Monitor (FL-505)?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice