Contact SupplierMultipara Monitor (FL-505) that we offer is appreciated for its accurate result display. Our Multipara Monitor (FL-505) features 12"1 color TFT display along with large fonts for easy readability. Multipara Monitor (FL-505) shows maximum 96-hour graphic and tabular trends of all parameters. It also features newest anti-electric and anti-defibrillation designing. Our Multipara Monitor (FL-505) can be easily used in all kinds of adverse environments.
Features
Power Requirements | Alarm range | 15-350bpm | |
AC 100-240 (AC), 50/60 Hz | S-T segment detection | Measurement range : 2.0 mV – 2.0mV | |
Power | 70VA | Alarm range : 2.0mV – 2.0mV | |
Temperature | 0-40 oC | Respiration | |
Humidity | 15-95% non-Condensing | Method | Thoraci impedance |
Patient Range | Adults, Pediatric, neonate | Measurement range | Adult0-120BrPm; |
Neonate/Pediatric 0 -150BrPM | |||
Performance Specifications | Apnea Alarm | Yes | |
Display | 12"1 Color TFT | Alarm | Yes audible and visual alarm |
Resolution : 800x480 | NIBP | ||
Multi displays selectable, including | Method | Automatic oscillometric | |
Standard display | Operation modes | Manual/Automatic/continuous | |
Large-font Display | Auto measure time | Adjustable | |
Trend coexist display | Measurement unit | MmHg/kPa selectable | |
OxyCRG dynamic view display | Measurement types | Systolic, diastolic, mean | |
Indicator | Alarm indicator light | Range of systolic pressure | Adult mode : 40-270mm hg |
Power indicator light | Pediatric mode : 40-200mm hg | ||
Battery indicator light | Neonate mode : 40-135 mmHg | ||
QRS beep and alarm sound | Range of diastorlic pressure | Adult mode : 10-210mm Hg | |
Interface | AC Power input socket | Pediatric mode : 10-150mm Hg | |
Network interface | Neonate mode : 10-100 mm Hg | ||
Battery | Rechargeable lead-acid battery | Range of mean pressure | Adult mode : 20-23mm hg |
(for 1 piece) maximum 12 hours for charging | Pediatric mode : 20-165mm Hg | ||
2 Hours for continuous working | Neonate mode : 20-110mm hg | ||
Trend time | 1-96 hours | Accuracy of blood pressure | The mean error shall be less than 5mm hg |
Alarm | User-adjustable high and low limits 2-level | Measurement | The standard deviation shall be less than 8mm Hg |
Audible and visual alarm | Over-pressure protection | Double safety protection | |
Networking | Connected to central monitoring system | Resolution | 1mm Hg |
Recorder | Built-in, thermal array | Alarm | Systolic, diastolic, mean |
Waveform : 3 channels | PR form NIBP | Measurement 40-240bpm | |
Paper width : 50mm | Resolution 1bpm | ||
Printspeed : 25mm/s | Accuracy + 3bpm or + 3% whichever is greater | ||
ECG | SpO2 | ||
Lead type | 5-lead and 3-lead selectable | Measurement range | 0-100% |
Lead selection | 5-lead I ; II ; II; avR: avL; avF;V | Resolution | 1.00% |
3-lead; I:II;III | Accuracy | +2% (70-100%adult/pediatric, non-motion) | |
ECG waveform | 2 channels | +3% (70-100%, Neonate, non-motion); | |
Gain selection | X 0.25x0.5;x1;x2; auto | 0-69% unspecified | |
Sweep speed | 12.5 mm/s, 25mm/s, 50mm/s | Alarm range | 1-100% |
Heart rate range | Adult 15-200bpm | Pulse rate | Range 20-24 bpm |
neonate/pediatric : 15-350bpm | Resolution : 1bpm | ||
Accuracy | +1% or + 1bpm, whichever is greater | Accuracy : +3 (non-motion) | |
Resolution | +1bpm | Alarm renge : 20-254bpm | |
Filter | Diagnostic mode : 0.05-100hz | Temperature | |
Monitoring mode : 0.5-40hz | Measurement range | 0-50oC (32-122oF) | |
Surgical mode : 1-20hz | Resolution | 0.1 oC | |
Protection | Withstand 4000VAC/50Hz voltage in isolation | Accuracy | +0.1oC (excluding the sensor) |
Sacling signal | 1mV + 5% | Channel | Dual-channel, provide T1;T2 |