Company Information
Ask for more detail from the seller
Contact SupplierMeasuring the total volume of cold portable water passing through the pipeline.
The Multi Jet meter operates on the velocity principle, that the water enters thorough the inlet and penetrate through the multi holes of the impeller cup and drives the impeller. The impeller is suspended by hydrodynamic forces to give minimum load on the bearings. The impeller rotation is magnetically transmitted to the register which the reading is made.
Apollo Multi Jet Brass Meter body and connectors made in High grade Brass metal with CNC Machining to maintain the accuracy of the dimension which is major criteria for the accuracy of the Brass Meters.
(1) in the lower zone from qmin inclusive up to but excluding qt is ±5%.
(2) in the upper zone from qt inclusive up to and including qs is ±2%;
Size(mm) | ISO 4064 Class | qs Overload Flow | qp Permanent Flow | qt Transitional Flow | qmin Minimum Flow | Minimum Reading | Maximum Reading |
---|---|---|---|---|---|---|---|
m3/h | L/h | m3 | |||||
15 | B | 3 | 1.5 | 120 | 30 | 0.00005 | 99,999 |
20 | B | 5 | 2.5 | 200 | 50 | 0.00005 | 99,999 |
25 | B | 7 | 3.5 | 280 | 70 | 0.00005 | 99,999 |
32 | B | 12 | 6.0 | 480 | 120 | 0.00005 | 99,999 |
40 | B | 20 | 10 | 800 | 200 | 0.00005 | 99,999 |
50 | B | 30 | 15 | 3000 | 450 | 0.00005 | 99,999 |