Contact SupplierBuy corrosion resistant and highly durable Axis Hot Runner Temperature Controllers from us as per requirements. Our company is ranked among responsive and responsible traders and fabricators of a comprehensive assortment of Axis Hot Runner Temperature Controllers. They function optimally and guarantee long service life.
Auto Control Mode | Computer-Calcu Cycle System |
---|---|
Control Accuracy | +-0.1 F(+-0.1 c) dependent on the total thermal system |
Temperature Range | 32 to 999F (0 to 537c) |
Temperature Stability | +-0.5% of full scale over the ambient range of 32 to 131F (0 to 55c) |
Calibration Accuracy | Better than 0.2% of full scale |
Power Response Time | Better than 0.3 second |
Process Sampling | 100 milliseconds |
F / c | Jumper-selectable |
AdjComp Step Control Mode | Variable stepping voltage, phase fired |
AdjComp Step System Duration | Approximately 5 minutes |
AdjComp Step Output Voltage | Steps approximately from 25v RMS with 240Vac line output phase-fired |
AdjComp Step Override Temp. | 221F (105c) |
Compensated | Adjustable from 0-100% Maintain output Power to with 1% of setting |
Operational Mode Priority |
|
Safe Change Function | Use of the Safe Change feature does not eliminate the need for careful installation and removal of controller. |
Voltages | 110 Vac or 240 Vac nominal, single phase |
---|---|
Power Capability | 15 amperes, 3600 watts 240 Vac, 15 amperes, 1800 watts 120 Vac |
Overload Protection | Triac and load use high speed fuses, Both side are Fused(ABC-15 GBB, |
Power Line Isolation | Optically and transformer isolated from ac line. Isolation voltage is greater than 2500 volt. |
Output Drive | Internal solid state triac, triggered by ac zero crossing pulses |
Setpoint Control | Two buttons up or down, Resolution1oF (1oc) |
---|---|
% Power Control | Two buttons up and down |
Mode Control | Push button switch with LED indicator f or manual mode |
Display | Top - 3-digit filtered LED, Bottom - 4-digit filtered LED |
Status Indicators | Heater output,Soft-Start,Manul,alarm |
Power On-Off | Rocker Switch,UL,CSA approved |
Input Voltage | 110 ~, +/240Vac, -10% |
---|---|
Voltage Frequency | 50-60 HZ |
DC Power Supplies | Internally generated, regulated and temperature compensated |
Module Power Usage | Less than 6 watts,exciuding |
Dimensions | Load 2" W * 7" H * 71/2" D(5.08cm*17.78cm*19.05cm) |
Thermocouple (T/C) sensor | Type "J" grounded or ungrounded, Type "k" (Jumper-selectable) |
---|---|
External T/C Resistance | Maximum 100 ohms for rated accuracy isolated from ground and supply voltages |
T/C Isolation | Automatic, better than 0.02 F/ F (0.01 c / c) Potentiometric |
Cold Junction Compensation | Diode clamp, RC filter 10 Megohms |
I nput Type | |
I nput Protection | Better than 0.05 F/ F(0.03 c / c) |
I nput Impedance | Greater than 999 F (0 to 537 c) |
I nput Amplifier Stability | Greater than 100dB |
I nput Dynamic Range | Greater than 70dB |