Contact SupplierWe are offering motion condition tester.
Insulation resistance of windings at 500 VDC0.25 mA (max) for detecting leakage between winding to winding or to earth.
Resistance of the windings for detecting the open circuits loose connections in a winding coil. Inductance of the windings for detecting the short circuits between individual turns of a winding. Inductance of the windings with respect to different positions of rotor for detecting blow holes or cracks in the rotor bars. All these defects can be checked with in a few minutes without dismounting the equipment (after switching off the power supply) Motor Condition Tester MCT-9 comes along with a carry case, test leads and 6 Nos. AA size, 1.5 V cells.