Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    MODEL MAMMOMAT 3000 NOVA

    • AEC DETECTOR (POSITIONING ASSEMBLY)Solid-state, sandwich design
    • Focal spot size, mm (X-RAY TUBE)0.1 and 0.3
    • DIMENSIONS (HXWXD) CM, (IN) (DISPLAY)217 x 52 x 22.5 (85.4 x 20.5 x 9) stand, 196 x 70 x 34 (77 x 27.6 x 13.4) generator
    • ROTATION, ° (ILLUMINATION LEVEL, maximum ft-candles)+135, -180, motorized rotation
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 14 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • RADIATION SHIELD (X-RAY TUBE)Yes
    • DIMENSIONS (HXWXD) CM, (IN) (DISPLAY)217 x 52 x 22.5 (85.4 x 20.5 x 9) stand, 196 x 70 x 34 (77 x 27.6 x 13.4) generator
    • Kv range (X-RAY GENERATOR)23increments of 1 kV
    • GENERATORHigh-frequency, single- or two-phase power supply
    • Focal spot size, mm (X-RAY TUBE)0.1 and 0.3
    • Bucky (GENERAL RADIOGRAPHY) optional18 x 24 cm, 24 x 30 cm; mounted on pivoting arms
    • ROTATION, ° (ILLUMINATION LEVEL, maximum ft-candles)+135, -180, motorized rotation
    • AEC DETECTOR (POSITIONING ASSEMBLY)Solid-state, sandwich design
    • L x w, cm (in) (CONTROL CONSOLE)195 x 65 (76.8 x 25.6)
    • POWER NEEDED208 VAC, single phase
    • mAs RANGE (X-RAY TUBE)2-600, Mo tube. The mAs range is 2 with the tube.
    • Anode type (X-RAY TUBE)Rotating 8,800 rpm
    • Vertical axis, cm (in) (POSITIONING ASSEMBLY)65-135 (25.6-53.1) motorized

    • Dual Bucky System: Small 18 x 24 and Large 24 x 30
    • Generator: High Frequency X-Ray Generator
    • Tube: Dual Track Molybdenum/Rhodium X-Ray
    • Focal Spots: .01mm and .3mm Focal Spot Sizes
    • Exposure Modes: Three Exposure Modes (Automatic
    • Optimization of Parameters (AOP), Fully Automatic, and AECSemi Automatic/Manual
    • Magnification: 1.3 and 1.9 Magnification Factors – Single Platform
    • Telescopic Motorized Positioning Column: Command Buttons
    • Located on Each Side and Top of the Column for Easy Access
    • Digital Display: Compression Pressure, Breast Thickness, Size
    • of X-Ray Field, and Magnification Factor
    • Foot Pedals: Motorized Compression Controlled by Two
    • Compression/Decompression Foot Pedals with Manual Fine Tunning
    • Compression Paddles: Slide Mount for Stability/Easy of Mounting
    • System Also Includes: Image Receptor, Control Console,
    • Lead/Glass Operator Radiation Shield, Face Guard, Operator
    • Keyboard/Console, DataFlash Patient ID System, Operator
    Generator
    • High-voltage wave form: Multipulse
    • Exposure voltage : 23kV to 35kV, adjustable in increments of 1kV
    • mAs range : Mo X-ray tube: 2mAs to 560 mAs (mAs-mode)up to 600mAs (AEC-mode)
    • Mo/W X-ray tube : 2mAs to 710 mAs (mAs-mode) up to 752 mAs (AEC-mode)
    • Exposure times : From 10 ms to 4s , From 10 ms to 7s for magnification techniqueAutomatic exposure control
    • Automatic exposure control (AEC): Microprocessor controlled, transparency compensation
    • Detectors: Semi conductor detector
    • Accuracy of optical density (2-6 cm): ± 0.15 OD from the mean optical density for predefined film screen combinations (separately for each grid table, magnification table and anode-filter combination at appropriate clinical kV).
    • Density correction : ± 3 exposure points, adjustable in 1/8 step increments
    • Film-screen combinations : 2; User selectable on the generator control panel (H/D).


    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for MODEL MAMMOMAT 3000 NOVA?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice