Contact SupplierMicro controller-2016 Features:
 LCD monitor is used to view of input & output voltage,Output current and freis quency.Â
 Auto/manual output on.Â
  Output ON adjustable time delayÂ
  Over load cut off time settingÂ
  Voltage cut off time settingÂ
 Last 30 fault events Data log viewÂ
  Output voltage adjustable setting (210-245)VoltÂ
 Sensitivity and regulation adjustableÂ
 Microcontroller based Programmable Control circuits
Â
Salient Features:
  High efficiency & Fast response.
  Wide input voltage range & Audiable alarm for trip conditions.
  99.99% failure proof control circuit.Â
  No over under, shoots and hunting.Â
  Built in bypass switch upto 100 Kva.Â
 Less active component avoids failure ratings.Â
  Special electronic circuit to operate on gensets.Â
  No effect of power factor and frequency variations.Â
  Single PCB for three phase sensing and correction.Â
  Voltage at speed related to rate of fluctuations and avoids oscillations & hunting In dc motor drive.Â
  Variable speed high torque dc servo motor proportionally controls corrections.Â
  Rugged and smooth ac motor drive control through optoisolator circuit which is Highly reliable.Â
  Separate isolated PCB for triac switching for motor.
High Reliablity :
 High reliability due to digital and controlling using micro controllerÂ
 All components sourcedfrom reputed manufacturers, confirm to IS/BS/VDU standardsÂ
  All raw material inspection as per internal components manualÂ
  Individual assemblies and sub assemblies tested separately.Â
  Individual assemblies tested on full load at 55 deg c in oven for 48 hours to minimize failureÂ
  Final equipment tested for accelerated life test to identify and replace any weak links.
Productions:
 Input and Output Low Voltage protections.Â
 Input and Output High Voltage protections.Â
  Phase rotation/single phasing preventer.Â
  Input protection using HRC fuse.Â
  Control circuit protection using fast blow fuse.Â
  Electronic overload protection.
LCD Specifications:Â
 16*4 lcd display is used for easy reading of parameters.Â
 True rms sensing and reading of voltage and current.Â
  100 event error log facilities for easy diagnosation of fault level.Â
  Internal variable timer is adopted for on time delay and overload trip of scvs.Â
  Selectable phase reverse function.Â
  Selectable auto on function.Â
  Less analog circuit and hence failure rate is reduced.Â
  Built in digital meter for monitoring the voltage / current & frequency.Â
  Separate isolated PCB for triac switching for motor.