Preferred Buyer Location India, United Arab Emirates, Afghanistan, Antigua and Barbuda, Anguilla, Angola, Bolivia, Bhutan, Botswana, Congo, Chile, Costa Rica, Dominican Republic, Ecuador, Guatemala, Guyana, Honduras, Haiti, Iraq, Jamaica, Kenya, Cayman Islands, Kazakhstan, Libyan Arab Jamahiriya, Madagascar, Myanmar, Mauritania, Mauritius, Maldives, Mozambique, Niger, Nigeria, Nepal, Panama, Peru, St. Pierre and Miquelon, Paraguay, St. Helena, Suriname, El Salvador, Trinidad and Tobago, Tanzania, United Republic of, Venezuela, Vanuatu
The Datascope SC 100 is an intra-aortic balloon pump that features Intellasync software. The .
Maquet CS100 IABP comes with Intellisync and offers a one-button start-up, automatically adapting to changing conditions, making it the right choice for any patient’s condition.
Automatically evaluates and selects optimal trigger source and lead
Sets inflation at the dicrotic notch and deflates IAB at the start of systole
Responds to changes in signal quality by selecting a new trigger source Automated trigger source and timing management to provide continuous, consistent support for your patient.
Fast, one-button start-up automatically conducts autofill and initiates 1:1 assist.
Full color, high contrast display tilts for easy viewing.<//li>
Display and keypad in laptop-style configuration, allowing caregivers to fold and detach the unit for remote operation. Easy-to-use keypad with an intuitive user interface.
Customizable display panel allows operators to adjust sweep speed, brightness, balloon waveform, and inflation markers.
Switch easily between three operation modes: Automatic, Semi-Automatic, and Manual.
Automatically evaluates and selects optimal trigger source and lead.
The system detects changes and easily adapts to new patient rhythms.
Fully annotated printouts with user-configurable waveforms and strip lengths.
Locking casters and durable design keep the CS100 secure in a variety of settings.
Dimensions
Height: 30 in (76.2 cm)
Width: 22.5 in (57.2 cm)
Depth: 13.2 in (33.5 cm)
On Cart
Height: 42.2 in (114.8 cm)
Width: 17.6 in (44.7 cm)
Depth: 23.4 in ( 59.4 cm)
Off Cart
Height: 28.2 in (71.6 cm)
Width: 11.3 in (28.7 cm)
Depth: 21.5 in ( 54.6 cm)
Monitor weight: 9.5 lb (4.3 kg)
Console weight: 133.2 lb ( 60.4 kg)
Color Display
Width:8.3 in (21cm)
Height: 6.2 in (15.8 cm)
viewing angle:
Up: 45°
Down 55°
Right 70°
Left 70°
Rotates 330°<?li>
Tilts180°
Detachable Laptop-like closure for storage and protection
ECG Trigger: Threshold dynamically adjusted by a system for high sensitivity and selectivity of the R-wave detection; Minimum = 120µV ± 20µV at normal gain; 40µV at max. gain
Pressure Trigger: The default trigger threshold is automatically adjusted to 38% of the difference between peak systolic and end-diastolic (avg. over multiple cycles); In variable mode: User-adjustable between 7 and 30 mmHg ± 3 mmHg
Pacer A Trigger: R-wave detection (as above) except pacer blanking is extended to 100 ms
Pacer V/A-V Trigger: V Pacer: fixed at a rate up to 185 bpm (no demand pacing) A-V Pacer: fixed at a rate up to 125 bpm (no demand pacing) with A-V intervals between 80-224 ms
Tall T-Wave Rejection: Rejects all T-Waves where the Q-T interval is <300 ms and the amplitude is <70% of the QRS input amplitude
Pacer Rejection: Rejects all pulses of amplitude ± 2.0 mV to ± 700 mV and durations between 0.1 ms to 2.0 ms with 1) No tail; 2) 100 ms time constant tail < 1 mV; 3) 25 ms time constant tail < 1 mV; 4) 4 ms time constant tail < 2 mV