Company Information
Ask for more detail from the seller
Contact SupplierFeatures | Standard | Optional(on request) |
---|---|---|
Mixing ratio range | UP to 30.0(in 0.1 Increments) | - |
Accuracy tolerance | Down to 1% *User settable | - |
Flow rate | 0.1 to 4 liters per minute | Higher flow rate |
Maximum fluid pressure | 30 bar | 240 bar |
Air pressure requirement | 4-7bar | - |
Electrical power requirement | 230v AC 50 Hz Single phase | As per available power source |
Multi-colour application(colour change facility) | 4 colours, 4 hardeners & 2 solvents, 4 different recipes can be stored | Modular system. No limit to colour addition and recipes |
Flushing | Manual as well as inbuilt auto flushing cycle programmable sequential air-solvent purge | - |
Material usage reporting | Reporting of component consumption accumulative+ daily consumption | - |
Pot life monitoring | Pot life monitoring of mixed material | - |
Pressure monitoring | Online system health checking by pressure monitoring | - |
Level Monitoring | Online container level monitoring based on materialconsumption | - |
Remote Operator panel | - | Ex-proof remote operator panel |
Communication | RS 232 communication port for printer/network/PC. Protocol modbus | SCADA |
OperatorInterface | Touch screen graphical display with audio visual alarm system | - |