Loss On Heating Thin Film Oven

Listing ID #4375202

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

Loss on Heating /Thin Film Oven     Purpose for modified Bitumen testing. various tests like Loss of Weight, Softening Point, Penetration, Elastic recovery Test etc. are to be done....
View More Details
Send Enquiry

Company Information

  • Member Since 15 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Loss on Heating /Thin Film Oven
 
 

Purpose for modified Bitumen testing. various tests like Loss of Weight, Softening Point, Penetration, Elastic recovery Test etc. are to be done on the residue of thin Film Oven test. Thin Film Oven can conduct “Thin Film Oven Test” (IS : 9382-1982) as well as “Loss in weight of bitumen & Flux-Oils” (IS: 1212-1978, BS: 2000 (P-45), ASTM-D6, D 1754, AASHQ - T47, T 179)
A double walled oven 230 V., 50 Hz and 1 Phase, inside Chamber 400 mm x 400 mm x 400 mm of Stainless Steel 304 & outside mild Steel Stoving Painted, in between the walls proper insulation; with a glass view window. Temperature range from ambient plus 10°C to 200°C & working temperature 163°C ± 1°C, controlled by PID Micro Processor controller dual display with safety alarm.
Rotating Shelf for Loss on Heating Test: A detachable perforated metal shelf of approx 250 mm dia (having provision to keep 9 no sample containers of 55 mm ID x 35 mm internal depth with flat bottom ) Suspended inside the oven which is rotated by a vertical shaft to which reduction gear is fitted from outside at a rate of 5 to 6 RPM.
For Thin Film Test: Another detachable perforated metal shelf of approx 340 mm Dia (with provision to keep four Aluminium dishes with 140 mm 1D x 10 mm depth with Flat Bottom) provided that can be fitted in place of 250 mm dia shelf for Thin Film Test.
Ventilation of the oven by means one round hole near the top & near the bottom on each of the two sides is provided.



Company Details close-icon

First and only licencee who got ISI mark for Laboratory Electric oven in India
General Safely & Testing Standards
If Instrument is electrically operated first of all safety of the person is 100% must.
Mental Satisfaction Regarding Instrument.
We can give any Accuracy.
You can depend or Rely 100% an our temperature shown or controlled.
Like Clinical Thermometer everything depends on Temperature accuracy which is tested as per as IS:2480
All Wiring of Instruments are tested as per IS: 302
Every Instrument is tested on 1000 volts for 1 minute.
All Wiring is done by ISI Colour code red for phase, black for neutral and green for earthing.
All Wiring with Teflon Coated Wires which can stand it self 250°C temp.
All Wiring done with Thimbles.
If an item fitted with Thermostat or Glass Thermometer both duly checked or calibrated with standard references.
Instrument is meant for years not for one year.
Every Instrument is tested as per their temperature specification, accuracy, uniformity & physically
Providing 100% operational safety to all customers is our primary concern.
Quality is our only advertisement .
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Loss On Heating Thin Film Oven?

Quantity
Seller Contact Details

Browse Related Categories

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice