Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Lightning Arrester

    • SpecificationsLenght
    • Original Colored Printed Carton Box ( 670 X 127 X 125 )Working Principle
    • Ø 22 Mm  ( Inox )  Stainless SteelConnection Adapter
    • Ce , Iso 9001 , Metu (MIDDLE East Technical University / Turkey) Cpri ( Cpri Central Power RThe ESE LAarch Institute ) IndiaGuarantee
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 14 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Product Details no_img_icon

    • Ce , Iso 9001 , Metu (MIDDLE East Technical University / Turkey) Cpri ( Cpri Central Power RThe ESE LAarch Institute ) IndiaGuarantee
    • Original Colored Printed Carton Box ( 670 X 127 X 125 )Working Principle
    • Stainless Steel ( Inox )Certificate
    • The ESE LA Active Lightning Rod Unit ( Olp 214 )Details
    • 650 MmWidth
    • 220 MmCapture End
    • SpecificationsLenght
    • Suitable For 2 ” ( Inch) Pole And Made Of 5mm Chrome Nickel Plated SheetWeight
    • Ø 22 Mm  ( Inox )  Stainless SteelConnection Adapter
    • 4.100 Gr.Packaging
    • E.S.E. ( Early Streamer Emission )Physical Structure
    • 35 Years Guarantee Certificate Issued By Ministry Of IndustryProduct Code

    LIGHTNING ROD

    Active Lightning Rod Unit is operating based on The ESE LA (Early Streamer Emission) system during thunderstorm. The body of the Ligthning Rod Unit, the part that will convey the lightning, has been made from completely inox (stainless steel) material called “XL 304 Chrome”.

    The Lightning Rod Units are the 1st and the pioneer Lightning Arrester that has been manufactured in Turkey by Chrome in the area.

    WORKING PRINCIPLE

    E.S.E. – EARLY STREAMER EMISSION

    Active Lightning Rod Unit is operating based on The ESE LA (Early Streamer Emission) system during thunderstorm. Clouds that electrical charge condensed, increase the atmospheric electrical load to the range of approximately 10 kV / m.  From this moment on, OLP 214“ESE Plus” Active Lightning Rod Unit, begins to store that energy, in its own ion generator.

    This increasing energy stored at the ion generator’s own top layers creates a conductive path upwardly from the ion ends, between the lightning rod and the cloud.

    So that the small discharges are formed when there is no lightning discharge yet.

    When the electrical fields intensity increases, the stored energy will also increase in proportion then the high voltage generator starts working as well.

    With the introduction of this generator, high voltage arcs occurred between the ion ends, transmits the lightning discharge firstly to the lightning rods capturing end and then with the copper on the plant to the ground which enable the system to be completed and thus provides life and property safety to the human beings in their living areas.

    THE ACTIVE LIGHTNING

    ACTIVE LIGHTNING ROD SUPERIOR PROPERTIES:

    • The Plus Active Lightning Rod Unit is the First to be tested and pass the conformity of the French NFC 17-102 Standarts (Appendix C), made by METU (Middle East Technical University) in Turkey on March 2005. This can be checked through official records.
    • The Impulse Voltage Generator is coated with the epoxy insulator, resistant to to 300 kV / cm.
    • The unit Body Part is produced from XL 304 material. Therefore it does not

    Tarnish and rust and it is does not get affected from the acid rains.So it will also not happen any problem during the unit’s operation.

    • With its Compact and portable structure, it facilitates the transport and the assembly stages.
    • The protection area is always at maximum level.
    • Hologram System is Available.
    • The Plus “OLP 214”, Active Lightning Rod Units have been passed through the tests of CPRI (Central Power RThe ESE LAarch Institute)/India which is an accredited body by many worldwide cooperation.
    • They are subjected to Five separate Tests inlcuding product Surfaces During Production.
    • In certain Periods, our products operabilities have been tested and documented at test centers ( METU – March 2005, February 2011)

    The has;  ISO 9001 / CE / Warranty Certificate / METU Test Report / CPRI Test Report at prThe ESE LAnt. Also the ??process for GOST Certificate has been initiated and it is expected to be finalized by September 2014.

    As The, we always improve our selves and products quality by adding new features, products & certificates.


    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Lightning Arrester?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice