    InRow Chilled Water Cooling

    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world

    Close-coupled, chilled water cooling for medium to large data centersExplore InRow RC in 3D animation.The InRow Chilled Water unit closely couples the cooling with the IT heat load. This prevents hot....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 7 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Close-coupled, chilled water cooling for medium to large data centers
    Explore InRow RC in 3D animation.
    The InRow Chilled Water unit closely couples the cooling with the IT heat load. This prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. Available with and without humidity control, these products are intended to meet the diverse requirements for medium to large data centers. Data center operators looking to improve efficiency or deploy high density servers will benefit from the modular design of the InRow Chilled Water products. The intelligent controls of the InRow Chilled Water products actively adjust fan speed and chilled water flow to match the IT heat load to maximize efficiency and address the dynamic demands of today's IT environments.

    Serviceability
    • Easy service access Allows for all serviceable components to be replaced/maintained by easily accessible panels/doors.
    • Agility
    • Casters Provides flexibility to move the unit to wherever cooling is required.
    • Scaleable densities Allows for higher densities to be achieved by integrating containment with room, row and rack cooling system architectures.
    • Modular design Modular design provides scalable solutions to add cooling as demand increases.
    • Total Cost of Ownership
    • Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
    • Row-based architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.
    Availability
    • Dual A-B power inputs Draws power from the UPS for power protection with dual feeds for redundancy.
    • Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
    • Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
    • Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
    • Rack inlet control Rack inlet control guarantees inlet temperature to IT equipment.
    Manageability
    • Building management system integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.
    • Real-Time Capacity Monitoring Real-time display of current and available cooling.
    • Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.


    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for InRow Chilled Water Cooling?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice