    Infant Radiant Baby Warmer

    • Side panelsAluminum hinged acrylic panels
    • Maximum load10 Kgs
    • Weight70 Kgs (nice 2010BC)
    • Mattress from floor95 cms
    • Supply TypeManufacturer, Exporter, Supplier, Retailer, Distributor, Trader
    • Preferred Buyer Location India ( Maharashtra only ) & All other countries
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 8 Years
    • building Nature of Business Distributor
    • gst icon GST No. 27AIPPG0212M2Z9

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Maximum load10 Kgs
    • Weight70 Kgs (nice 2010BC)
    • Heater module swivel±90 Degree
    • Dimesnions85 cms(L) x70 cms(W)x185 cms(H)
    • Side panelsAluminum hinged acrylic panels
    • Maximum load for monitor shelf4.5 Kgs
    • Mattress73 cms (L) x 53 cms (W) x 5 cms (H)
    • Mattress from floor95 cms

    Features:

    • Micro Controller based Electronics
    • Controls - Servo Skin/ Apgar
    • Pre-warm - Use the equipment with 30% Heater Output in Manual Mode.
    • Programmable Mute time
    • No need of calibration required for temperature probe.
    • High Intensity Quartz Heating element for effective Radiation (Ceramic heater Optional)
    • Halogen Observation Lamp
    • The Heater Module rotates 90° to both sides to facilitate
    • X-Ray Procedures.
    • The Parabolic Reflector is designed to send uniform heat to the bed surface.
    • Memory Backup to restore set temperature and previous mode, in case of power failure.
    • Optimum Bed dimensions ensure optimum work space for the nursing staff.
    • Comprehensive Alarms and safety cut-offs.
    • Alert (Alarm) when sensor is detached from the patient's skin (optional)
    • Instant Warming and Uniform heating

     

    Controller

    • Electronics : High speed micro controller
    • Mode of operation : Servo skin, manual & apgar
    • Skin mode control range : 30 Deg. C to 38 Deg. C
    • Manual mode timer : 1 min to 15 mins (selectable), 15 mins to 30 mins (optional)
    • Apgar timer : Alerts at 1, 5, 10, 15 & 20 mins (selectable)
    • Percentage of heater output : 10% to 100% in 10% increments
    • Memory back up : Equipment restores the previous settings
    • Programmable mute time : User can select the mute time
    • Safety heater cut off : If the skin sensor is removed from the baby's skin
    • Over temperature heater cut off : If the skin temperature is >39 Deg. C in any skin/manual mode
    • Temperature sensor (probe) : Thermistor sensor
    • Accuracy of skin sensor : ±0.1 C
    • Accuracy of skin probe Interchangeability : 0.2 C
    • Calibration of skin sensor (probe) : No need of calibration after Changing new probe
    • Heater element : Quartz Infrared heater Ceramic heater (optional)


    Other Details

    • Power rating : 230V AC, 50Hz, 700 W
    • Maximum heater wattage : 600 Watts
    • Maximum power requirement : 700 Watts
    • Examination light : 12V, 50W Halogen lamp
    • X-ray facility : Underneath the bed
    • Mattress tilt : ±30 degrees on both sides
    • IV pole : Maximum load 2.2 Kg
    • Pump mounting pole : Maximum load 2.2 Kg
    • Castor : 4” castors 4 Nos. (2 with brake & 2 without brake
    • Monitor shelf : 2 Nos. Fixed
    • Height adjustable heater module : Available only in nice 2010
    • Cabinet : Available only in nice 2010BC
    • Operating noise level : <50 dBA


    Controller Alarms:

    • Check patient If the skin sensor is removed from
    • the baby's skin
    • Skin temperature high > 1.0 C from the set temperature
    • Skin temperature low < 1.0 C from the set temperature
    • Skin temperature probe fail Probe short or open
    • Over temperature If skin temperature is 39 C
    • Heater fail Heater defect
    • System fail Electronic component defect
    • Power fail AC power interruption


    Environmental

    • Operating temperature - 15° C to 35° C
    • Storage temperature - -20° C to 60° C
    • Operating humidity - 5% to 90% RH, non condensing
    • Storage humidity - 0% to 99% RH, non condensing
    • Altitude - Sea level to 1-9 miles, 3 Km
    • Quality - ISO 9001:2000 & ISO 13485:2003
    • Electrical & product safety - IEC 60601-1, IEC 60601-1-2, IEC 60601-1-4, IEC 60601-2-21


    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Infant Radiant Baby Warmer?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice